background image

73

41.   In the 

Intel(R) AMT Power Control 

menu

select 

Idle Timeout

 then press Enter. 

Enter the timeout value (1-65535).

Intel(R) Management Engine BIOS Extension v11.0.0.0005/Intel(R) ME v11.0.0.1205

Copyright(C) 2003-15 Intel Corporation. All Rights Reserved.

INTEL (R) AMT POWER CONTROL

This configurations are effective only after AMT provisioning has started

Intel (R) ME ON in Host Sleep States         

    <Mobile: ON in S0,

                                                                  ME Wake in S3, S4-5

                                                                  (AC only)> 

 

Idle Timeout                                                

65535

                        <ENTER> = Complete Entry     [ESC]= Discard Changes

Timeout Value (1-65535)

42.   Select Previous Menu until you return to the 

Main

 

Menu

. Select 

Exit 

then press Enter. 

Type 

Y

 then press Enter.

Intel(R) Management Engine BIOS Extension v11.0.0.0005/Intel(R) ME v11.0.0.1205

Copyright(C) 2003-15 Intel Corporation. All Rights Reserved.

MAIN MENU

> Intel (R) ME General Settings

> Intel (R) AMT Configuration

MEBx Exit

         Exit

[

↑↓

] = Move Highlight     [Enter] = Select Entry           [Esc]= Exit

 65535

40.   In the 

Intel(R) AMT Power Control 

menu

select 

Intel(R) AMT ON in Host Sleep 

States

 then press Enter. Select an option then press Enter.

Intel(R) Management Engine BIOS Extension v11.0.0.0005/Intel(R) ME v11.0.0.1205

Copyright(C) 2003-15 Intel Corporation. All Rights Reserved.

INTEL (R) AMT POWER CONTROL

Desktop : ON in S0

Desktop : ON in S0, ME Wake in S3, S4-5  

Intel (R) AMT ON in Host Sleep States         

   

<Desktop: ON in S0,

                                                                  ME Wake in S3, S4-5>

                                                                 

Idle Timeout                                              

  65535

[

↑↓

] = Move Highlight   [Enter] = Complete Entry  [Esc]= Discard Changes

These configurations are effective only after AMT provisioning has started

Содержание SD631-C236

Страница 1: ...1 SD631 C236 Q170 ATX Industrial Motherboard User s Manual A 415 M 2001 ...

Страница 2: ... Statement on Class B This equipment has been tested and found to comply with the limits for a Class B digital de vice pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential in stallation This equipment generates uses and can radiate radio frequency energy and if not installed and ...

Страница 3: ...s Interfaces 20 RJ45 LAN Ports 21 USB Ports 21 Audio 22 I O Connectors 23 SATA Serial ATA Connectors 23 Digital I O Connector 23 Cooling Fan Connectors 24 Power Connectors 24 Chassis Intrusion Connector 25 Front Panel Connector 25 Standby Power LED 26 Expansion Slots 26 S PDIF Connector 27 Battery 27 SMBus Connector 28 LAN LED Connector 28 LPC Connector 29 Connecting the EXT RS232 RS485 Card to th...

Страница 4: ...extra care in han dling them to ensure against electrostatic build up 1 To prevent electrostatic build up leave the system board in its anti static bag until you are ready to install it 2 Wear an antistatic wrist strap 3 Do all preparation work on a static free surface 4 Hold the device only by its edges Be careful not to touch any of the components contacts or connections 5 Avoid touching the pin...

Страница 5: ...cable Length 500mm Thermal solution For 35W Height 37 3mm Thermal solution For 65W Height 72 8mm Thermal solution For 95W Height 69 3mm for SD631 C236 only LPC EXT RS232 module 4 x RS232 ports LPC EXT RS485 module 4 x RS485 ports The board and accessories in the package may not come similar to the information listed above This may differ in accordance to the sales region or models in which it was ...

Страница 6: ...D signal resolution up to 1920x1200 60Hz HDMI resolution up to 4096x2160 24Hz Triple Displays VGA DVI I DVI D signal HDMI EXPANSION Interface 2 x PCIe x16 1 x16 or 2 x8 signal Gen 3 2 x PCIe x4 Gen 3 3 x PCI AUDIO Audio Codec Realtek ALC888S VD2 GR ETHERNET Controller 1 x Intel I210AT PCIe 10 100 1000Mbps 1 x Intel I219LM PCIe with iAMT11 0 10 100 1000Mbps only Core i7 i5 supports iAMT REAR I O Et...

Страница 7: ...ission Audio The Realtek ALC888S VD2 GR audio codec provides 5 1 channel High Definition audio output Important The 5V_standby power source of your power supply must support 720mA Wake On USB This function allows you to use a USB keyboard or USB mouse to wake up a system from the S3 STR Suspend To RAM state RTC Timer The RTC installed on the system board allows your system to automatically power o...

Страница 8: ...ning at a maximum transmis sion speed of up to 5 Gbit s 625 MB s and is faster than USB 2 0 480 Mbit s or 60 MB s and USB 1 1 12Mb s USB 3 0 reduces the time required for data transmission reduces power consumption and is backward compatible with USB 2 0 It is a marked improvement in device transfer speeds between your computer and a wide range of simultaneously accessible external Plug and Play p...

Страница 9: ... 8 6 5 2 1 5 6 1 2 6 5 2 1 6 5 2 1 JP5 JP8 JP6 JP19 JP7 1 5 Clear CMOS Data JP9 1 JP18 1 Chassis Intrusion 1 DVI I DVI D signal HDMI Line in optional Line out Mic in 5 2 4 3 7 7 7 7 7 7 3 3 1 JP17 1 JP15 JP16 1 JP13 1 1 JP14 1 J5 1 System Memory Standby Power LED Features Important Electrostatic discharge ESD can damage your board processor disk drives add in boards and other components Perform in...

Страница 10: ...e highly recommend using identical DIMMs Not all slots need to be populated Dual Channel DIMMs of the same memory configuration are on different channels Important You can populate either Channel A or Channel B first Note The system board used in the following illustrations may not resemble the actual board These illustrations are for reference only 1 Make sure the PC and all other peripheral devi...

Страница 11: ...equests will be accepted and pro cessed only if the LGA 1151 socket comes with the protective cap Note The system board used in the following illustrations may not resemble the actual board These illustrations are for reference only 7 Seat the module vertically pressing it down firmly until it is completely seated in the socket 6 Grasping the module by its edges position the module above the socke...

Страница 12: ...he LGA 1151 CPU socket on the system board 4 Unlock the socket by push ing the load lever down moving it sideways until it is released from the reten tion tab then lift the load lever up Retention tab Load lever 6 Remove the protective cap from the CPU socket The cap is used to protect the CPU socket against dust and harmful particles Remove the protective cap only when you are about to install th...

Страница 13: ... the corner of the CPU socket shown on the photo The CPU s notch will prop erly fit into the socket s alignment key Alignment key Alignment key Gold triangular mark 8 Close the load plate then push the load lever down While closing the load plate make sure the front edge of the load plate slides under the retention knob Retention knob 9 Hook the load lever under the retention tab Load lever ...

Страница 14: ...covers the paste before you place the fan heat sink on top of the CPU 2 Place the heat sink on top of the CPU The 4 push pins around the heat sink which are used to secure the heat sink onto the sys tem board must match the 4 mounting holes around the socket Mounting hole 3 Orient the heat sink such that the CPU fan s cable is nearest the CPU fan con nector CPU fan connector 4 Rotate each push pin...

Страница 15: ...t setting pins 1 and 2 On 3 Now plug the power cord and power on the system 2 3 On Clear CMOS Data 1 2 On Normal default 3 1 2 3 1 2 JP9 Auto Power on Select JP10 JP10 is used to select the method of powering on the system If you want the system to power on whenever AC power comes in set JP10 pins 2 and 3 to On If you want to use the power button set pins 1 and 2 to On When using JP10 Power On fea...

Страница 16: ... to the jumpers setting 10 2 1 9 1 3 5 2 4 6 1 3 5 2 4 6 1 3 5 2 4 6 2 4 6 1 3 5 JP5 COM 1 JP1 COM 2 COM 1 COM 2 1 2 3 4 5 6 7 8 9 1 2 On RS232 default 3 4 On RS422 Full Duplex 5 6 On RS485 2 4 6 1 3 5 2 4 6 1 3 5 2 4 6 1 3 5 Pin RS232 RS422 Full Duplex RS485 1 DCD RXD DATA 2 RXD RXD DATA 3 TXD TXD N C 4 DTR TXD N C 5 GND GND GND 6 DSR N C N C 7 RTS N C N C 8 CTS N C N C 9 RI N C N C JP6 JP7 COM 1...

Страница 17: ...S232 with power JP4 COM 2 2 4 6 1 3 5 2 4 6 1 3 5 2 4 6 1 3 5 1 3 5 2 4 6 1 3 RI 2 4 DCD On RS232 default 3 5 5V 4 6 12V On RS232 with power USB Power Select 2 3 On 5V 1 3 2 1 2 On 5VDU 1 3 The power of the USB connectors voltage buses can be configured to either 5VDU or 5V The jumpers are located as illustrated above and correspond to each USB port number as listed below 2 JP number USB Port JP13...

Страница 18: ...use The Wake On PS 2 Keyboard Mouse function allows you to use the PS 2 keyboard or PS 2 mouse to power on the system To use this function BIOS Setting Configure the wake up function of PS 2 keyboard mouse in the Advanced menu ACPI Con figuration submenu of the BIOS Refer to the chapter 3 for more information The rear panel I O ports consist of the following 2 RJ45 LAN ports 4 USB 3 0 ports 2 USB ...

Страница 19: ...or more information COM 1 RS232 422 485 COM 1 2 10 9 I C Battery 2 10 9 COM 2 RS232 422 485 COM 3 4 5 6 RS232 COM 2 COM 3 COM 4 COM 5 COM 6 RXD DCD TXD DTR GND DSR RTS CTS RI 10 2 1 9 Graphics Interfaces The display ports consist of the following 1 DVI I DVI D Signal port 1 HDMI port 1 VGA port VGA Port The VGA port is used for connecting a VGA monitor Connect the monitor s 15 pin D shell ca ble c...

Страница 20: ...2 0 1 1 ports USB 1 4 and two onboard USB 2 0 1 1 ports USB 5 6 The 10 pin connector allows you to connect 2 additional USB 2 0 1 1 ports USB 7 8 9 10 13 14 The additional USB ports may be mounted on a card edge bracket Install the card edge bracket to an available slot at the rear of the system chassis and then insert the USB port cables to a connector BIOS Setting Configure these onboard USB dev...

Страница 21: ...e a USB keyboard or USB mouse to wake up a system from the S3 STR Suspend To RAM state To use this function Audio Rear Audio The system board is equipped with 2 audio jacks A jack is a one hole connecting interface for inserting a plug Line out Jack Lime This jack is used to connect a headphone or external speakers Mic in Jack Pink This jack is used to connect an external microphone Driver Install...

Страница 22: ...The Serial ATA connectors are used to connect Serial ATA devices Connect one end of the Se rial ATA data cable to a SATA connector and the other end to your Serial ATA device The system board package comes with a power cable that must be connected from the system board s peripheral power connector to the SATA drive s power connector in order to provide power to the drive BIOS Setting Configure the...

Страница 23: ...ent to the processor s Voltage Regulator Module VRM The power connectors from the power supply unit are designed to fit the 24 pin and 8 pin connectors in only one orientation Make sure to find the proper orientation before plugging the connectors The system board requires a minimum of 300 Watt power supply to operate Your system configuration CPU power amount of memory add in cards peripherals et...

Страница 24: ... Front Panel 2 10 9 I C Battery 2 10 9 HDD LED HDD LED This LED will light when the hard drive is being accessed RESET SW Reset Switch This switch allows you to reboot without having to power off the system ATX SW ATX Power Switch This switch is used to power on or off the system PWR LED Power Standby LED When the system s power is on this LED will light When the system is in the S1 POS Pow er On ...

Страница 25: ...cs card into the x16 slot align the graphics card above the slot then press it down firmly until it is completely seated in the slot The retaining clip of the slot will automatically hold the graphics card in place PCI Slot The PCI slot supports expansion cards that comply with PCI specifications You can install a PCI expansion card or a customized riser card designed for only 2 PCI slots expansio...

Страница 26: ...audio cable is aligned with pin 1 of the S PDIF connector 1 5 5V Key SPDIF out Ground SPDIF in S PDIF 2 10 9 I C Battery 2 10 9 The lithium ion battery powers the real time clock and CMOS memory It is an auxiliary source of power when the main power is shut off Safety Measures Danger of explosion if battery incorrectly replaced Replace only with the same or equivalent type recommend by the manufac...

Страница 27: ... system the BIOS message appears on the screen and the memory count begins After the memory test the message Press DEL to run setup will appear on the screen If the message disappears before you respond restart the system or press the Reset button You may also restart the system by pressing the Ctrl Alt and Del keys simultaneously Legends Scroll Bar When a scroll bar appears to the right of the se...

Страница 28: ... Thread s 0000006A 8192MB 2133 MHz 8192 MB Not Installed Not Installed Not Installed 31 D1 Stepping SKL PCH H C236 11 0 0 1205 CORPORATE 10 33 40 06 20 2016 Advanced Boot Exit Main Rev 5 0 Advanced The Advanced menu allows you to configure your system for basic operation Some entries are defaults required by the system board while others if enabled will improve the performance of your system or le...

Страница 29: ...I Configuration Wake on LAN Enabled After G3 S0 State Advanced F1 Help Select Item F5 F6 Change Values F9 Setup Defaults Esc Exit Select Item Enter Select SubMenu F10 Save and Exit InsydeH20 Setup Utility Rev 5 0 CPU Configuration This section is used to configure the CPU Intel R SpeedStep tm This field is used to enable or disable the Intel Enhanced SpeedStep Technology Turbo Mode Enable or disab...

Страница 30: ...n Advanced F1 Help Select Item F5 F6 Change Values F9 Setup Defaults Esc Exit Select Item Enter Select SubMenu F10 Save and Exit InsydeH20 Setup Utility Rev 5 0 Auto Disabled VGA DVI Boot display DVI VGA DVI HDMI VGA DVI VGA HDMI HDMI DVI HDMI VGA Keep IGFX enabled based on the setup options Video Configuration Internal Graphics Always Enabled PEG Boot display Advanced F1 Help Select Item F5 F6 Ch...

Страница 31: ...it SATA Controller s This field is used to enable or disable Serial ATA devices SATA Mode Selection The mode selection determines how the SATA controller s operates AHCI Mode This option allows the Serial ATA devices to use AHCI Advanced Host Controller Inter face RAID Mode This option allows you to create RAID or Intel Matrix Storage configuration on Serial ATA devices Serial ATA Port 0 1 2 3 4 a...

Страница 32: ...res settings relevant to PCI Express root ports PCI Express Root Port 1 Settings PCI Express Root Port 1 PCI Express Root Port 6 PCI Express Root Port 7 PCI Express Root Port 9 Advanced F1 Help Select Item F5 F6 Change Values F9 Setup Defaults Esc Exit Select Item Enter Select SubMenu F10 Save and Exit InsydeH20 Setup Utility Rev 5 0 Control the PCI Express Root Port PCI Express Root Port 1 PCIe S...

Страница 33: ...gement Technology In tel AMT BIOS extension Please refer to Chapter 6 for more information Enable Disable Intel R Active Management Tech nology BIOS Extension Note iAMT H W is al ways enabled This option just controls the BIOS extension execution Active Management Technology Support Intel AMT Support Enabled Un configure ME Disabled Advanced F1 Help Select Item F5 F6 Change Values F9 Setup Default...

Страница 34: ...an Speed Count 1 to Fan Speed Count 4 Set the fan speed The range is from 1 100 Rev 5 0 Serial Port 1 to Serial Port 6 Configure the settings to use the serial port Disable No configuration Enable User configuration RS485 Auto Flow Enable or disable RS485 auto flow Fan Speed Count 1 Fan Speed Count 2 Fan Speed Count 3 Fan Speed Count 4 COM Port 1 Base I O Address Interrupt RS485 Auto Flow COM Port...

Страница 35: ...o Flow COM Port 3 Base I O Address Interrupt COM Port 4 Base I O Address Interrupt COM Port 5 Base I O Address Interrupt Advanced F1 Help Select Item F5 F6 Change Values F9 Setup Defaults Esc Exit Select Item Enter Select SubMenu F10 Save and Exit InsydeH20 Setup Utility Disable 50 Disable 50 Disable 50 Enable 3F8 IRQ4 Disable Enable 2F8 IRQ3 Disable Enable 3E8 IRQ4 Enable 2E8 IRQ3 Enable 2F0 IRQ4...

Страница 36: ...d Storage Password Setup Page Storage Password Setup Page This option allowes you to set up storage password TPM Availability Set the TPM availability TPM Operation Enable or disable the storage and endorsement hierarchy This option will automatically return to No Operation Clear TPM Remove all TPM context associated with a specific owner Set Supervisor Password Set the supervisor s password and t...

Страница 37: ...ues F9 Setup Defaults Esc Exit Select Item Enter Select SubMenu F10 Save and Exit InsydeH20 Setup Utility Security Exit Rev 5 0 On Dual Boot Type Disabled Disabled Enabled Boot Security Mode Description Lock HDD security status is enable and lock Unlock HDD security status is enable and lock Change HDD security status is unlock and user changes to the new password Disable Remove HDD password from ...

Страница 38: ...Menu Normal Based on the boot normal priority it determines the EFI device first or the legacy device first Advance All boot devices follow the user s selection sequence Use and keys to arrange the priority of the listed boot devices Main Advanced F1 Help Select Item F5 F6 Change Values F9 Setup Defaults Esc Exit Select Item Enter Select SubMenu F10 Save and Exit InsydeH20 Setup Utility Security E...

Страница 39: ...to boot from a floppy drive instead of a hard drive place the floppy drive ahead of the hard drive in priority Exit Exit Saving Changes Select this field and then press Enter to exit the system setup and save your changes Load Optimal Defaults Select this field and then press Enter to load optimal defaults Discard Changes Select this field and then press Enter to exit the system setup without savi...

Страница 40: ...el name SD631 Q170 C236 Current BIOS version 65 05A New BIOS version 65 05A Updating Block at FFFFF000h 0 25 50 75 100 100 C SD631 Q170 C236 _ Information Please do not remove the AC power Note a You can take advantage of flash tools to update the default configuration of the BIOS SPI ROM to the latest version anytime b When the BIOS IC needs to be replaced you have to populate it properly onto th...

Страница 41: ...e performance of the system board Insert the DVD into a DVD ROM drive The autorun screen Mainboard Utility DVD will appear If after inserting the DVD Autorun did not automatically start which is the Mainboard Utility DVD screen did not appear please go directly to the root directory of the DVD and double click Setup For Windows 10 For Windows 8 1 ...

Страница 42: ... updating Windows INF files so that the Intel chipset can be recognized and configured properly in the system To install the utility click Intel Chipset Software Installation Utility on the main menu 1 Setup is ready to install the utility Click Next 2 Read the license agreement then click Yes For Windows 7 ...

Страница 43: ...s driver Click Next By default the Automatically run WinSAT and enable the Windows Aero desktop theme is enabled With this enabled after installing the graphics driver and the system rebooted the screen will turn blank for 1 to 2 minutes while WinSAT is running before the Windows 7 Windows 8 1 Windows 10 desktop appears The blank screen period is the time Windows is testing the graphics performanc...

Страница 44: ...estart this computer now then click Finish Restarting the system will allow the new software installation to take effect Audio Drivers To install the driver click Audio Drivers on the main menu 2 Click Yes I want to restart my computer now then click Finish Restarting the system will allow the new software installation to take effect 1 Setup is ready to install the driver Click Next ...

Страница 45: ...in menu 1 Setup is ready to install the driver Click Next 2 Click I accept the terms in the license agreement then click Next 3 Select the program featuers you want installed then click Next 4 Click Install to begin the installation 5 After completing installa tion click Finish ...

Страница 46: ...or Windows 7 only To install the driver click Kernel Mode Driver Framework on the main menu 1 Click Yes to install the update 2 The update is installed now 3 Click Restart Now to restart your computer when the installation is complete ...

Страница 47: ...on the main menu 1 Setup is ready to install the driver Click Next 2 Read the license agreement then click Next 3 Setup is currently installing the driver After installation has completed click Next 4 Please wait while the prod uct is being installed 5 After completing installa tion click Finish ...

Страница 48: ...rsions you need to access the operat ing system as an administrator to be able to install the utility 1 Setup is ready to install the driver 2 Click Next to continue 3 Read the license agreement then click I accept the terms in the license agreement Click Next 4 The wizard is ready to begin installation Click Install 5 Please wait while the program features are being installed ...

Страница 49: ...lla tion click Finish SD631 C236 Q170 Note Note The screenshot displayed above is for illustrative purpose only and may not resemble the actual screen The SD631 C236 Q170 HW Utility features the following tabs Information HW Health HW Healthset Watchdog and DIO Click on the tabs to access information about the board ...

Страница 50: ... the driver After installation has complet ed click Next 5 After completing installation click Finish Intel USB 3 0 Drivers For Windows 7 and Windows 8 1 To install the driver click Intel USB 3 0 Driver on the main menu 2 Read the license agreement then click Yes 1 Setup is ready to install the driver Click Next ...

Страница 51: ... then click Next IO Driver For Windows 8 1 and Windows 10 To install the driver click Intel Serial IO Driver on the main menu 1 Setup is ready to install the driver Click Next 2 Read the license agreement care fully Click I accept the terms in the Li cense Agreement then click Next ...

Страница 52: ...s now extracting files Note Before installing Microsoft Framework 4 5 2 make sure you have updated your Windows 7 operating system to Service Pack 3 2 Read the license agreement care fully Click I have read and accept the terms of the License Agree ment then click Install 5 Setup is now installing the driver 6 Click Finish ...

Страница 53: ...o monitor the current status of the SATA drives It enables enhanced performance and power management for the storage subsystem To install the driver click Intel Rapid Storage Technology on the main menu Please refer to Chapter 5 for more information 4 Click Finish 3 Setup is now installing the driver ...

Страница 54: ... main menu 1 The setup program is preparing to install the driver 2 The setup program is now ready to install the utility Click Next 3 Click I accept the terms in the license agreement and then click Next 4 Enter the necessary infor mation and then click Next 5 Select a setup type and then click Next 6 Click Install ...

Страница 55: ...es installing the Microsoft Visual C package prior to installing the utility Click Install 8 The setup program is cur rently installing the Microsoft Visual C package 9 Click Finish 10 Click Yes to restart your system ...

Страница 56: ... To install the reader click Adobe Acrobat Reader 9 3 on the main menu 1 Click Next to install or click Change Destination Folder to select another folder 2 Click Install to begin installa tion 3 Click Finish to exit installation ...

Страница 57: ...d disk drives to read and write data in parallel interleaved stacks Data is divided into stripes and each stripe is written alternately between two disk drives This improves the I O performance of the drives at different channel however it is not fault tolerant A failed disk will result in data loss in the disk array RAID 1 Mirroring Disk Array with Fault Tolerance RAID 1 copies and maintains an i...

Страница 58: ...el Rapid Storage Technology Main Advanced F1 Help Select Item F5 F6 Change Values F9 Setup Defaults Esc Exit Select Item Enter Select SubMenu F10 Save and Exit InsydeH20 Setup Utility Security Boot Exit Rev 5 0 ACPI Configuration Setting ACPI Configuration CPU Configuration Video Configuration Audio Configuration SATA Configuration USB Configuration PCI Express Configuration ME Configuration MEBX ...

Страница 59: ...me and or SATA drives It enables enhanced performance and power management for the storage sub system 1 Insert the provided DVD into an optical drive 2 Click Intel Rapid Storage Technology Utility on the main menu 4 Read the license agree ment and click I accept the terms in the License Agreement Then click Next 3 Setup is ready to install the utility Click Next 5 Go through the readme document to...

Страница 60: ...60 8 Click Yes I want to restart this computer now to complete the installation and then click Finish ...

Страница 61: ...Enable in the AMT field Enable Disable Intel R Active Management Technology BIOS Extension Note iAMT H W is al ways enabled This Option Just controls the BIOS ex tension execution Active Management Technology Support Intel AMT Support Un Configure ME Advanced F1 Help Select Item F5 F6 Change Values F9 Setup Defaults Esc Exit Select Item Enter Select SubMenu F10 Save and Exit InsydeH20 Setup Utilit...

Страница 62: ...ngine BIOS Extension v11 0 0 0005 Intel R ME v11 0 0 1205 Copyright C 2003 15 Intel Corporation All Rights Reserved MAIN MENU MEBx Login Intel R ME General Settings Intel R AMT Configuration MEBx Exit Intel R ME Password Move Highlight Enter Select Entry Esc Exit Exit system setup and save your changes Exit Saving Changes Load Optimal Defaults Discard Changes Main Advanced F1 Help Select Item F5 F...

Страница 63: ...Enter Select Entry Esc Exit Intel R ME Password 3 You will be asked to verify the password Enter the same new password in the space pro vided under Verify Password then press Enter Intel R Management Engine BIOS Extension v11 0 0 0005 Intel R ME v11 0 0 1205 Copyright C 2003 15 Intel Corporation All Rights Reserved MAIN MENU MEBx Login Intel R ME General Settings Intel R AMT Configuration MEBx Exi...

Страница 64: ...ate then press Enter Select Enabled or Disabled or password Protected then press Enter Intel R Management Engine BIOS Extension v11 0 0 0005 Intel R ME v11 0 0 1205 Copyright C 2003 15 Intel Corporation All Rights Reserved Change ME Password Local FW Update Enabled Move Highlight Enter Complete Entry Esc Discard Changes Disabled Enabled Password Protected 7 Select Previous Menu until you return to...

Страница 65: ...direction KVM Username and Password Enabled SOL Enabled Storage Redirection Enabled KVM Feature Selection Enabled Disabled Enabled 11 In the SOL Storage Redirection KVM menu select SOL then press Enter Select Enabled or Disabled then press Enter Intel R Management Engine BIOS Extension v11 0 0 0005 Intel R ME v11 0 0 1205 Copyright C 2003 15 Intel Corporation All Rights Reserved SOL Storage Redire...

Страница 66: ...abled KVM Feature Selection Enabled Disabled Enabled Move Highlight Enter Complete Entry Esc Discard Changes Move Highlight Enter Complete Entry Esc Discard Changes 14 Select Previous Menu until you return to the Intel R AMT Configuration menu Select User Consent then press Enter Intel R Management Engine BIOS Extension v11 0 0 0005 Intel R ME v11 0 0 1205 Copyright C 2003 15 Intel Corporation All...

Страница 67: ...rk Access Full Unprovision Remote Setup And Configuration Power Control INTEL R AMT CONFIGURATION Default Password Only During Stepup And Configuration Anytime Move Highlight Enter Complete Entry Esc Discard Changes Move Highlight Enter Complete Entry Esc Discard Changes 18 In the Intel R AMT Configuration menu select Network Setup then press Enter Intel R Management Engine BIOS Extension v11 0 0 ...

Страница 68: ...icated FQDN Shared Dynamic DNS Update Disabled Computer Domain Name Enter Complete Entry Esc Discard Changes 22 Select Shared Dedicated FQDN then press Enter Select Shared or Dedicated then press Enter Intel R Management Engine BIOS Extension v11 0 0 0005 Intel R ME v11 0 0 1205 Copyright C 2003 15 Intel Corporation All Rights Reserved INTEL R ME NETWORK NAME SETTINGS Host Name _ Domain Name _ Sha...

Страница 69: ...nfigure Network Access then press Enter Intel R Management Engine BIOS Extension v11 0 0 0005 Intel R ME v11 0 0 1205 Copyright C 2003 15 Intel Corporation All Rights Reserved INTEL R AMT CONFIGURATION Manageability Feature Selection Enabled SOL Storage Redirection KVM User Consent Password Policy During Setup And Configuration Network Setup Activate Network Access Full Unprovision Unconfigure Net...

Страница 70: ... Record Provisioning Server IPV4 IPV6 _ Provisioning Server FQDN _ RCFG TLS PKI Provisioning Mode PKI 30 In the Intel R Remote Setup And Configuration menu select Provisioning Re cord then press Enter Intel R Management Engine BIOS Extension v11 0 0 0005 Intel R ME v11 0 0 1205 Copyright C 2003 15 Intel Corporation All Rights Reserved INTEL R REMOTE SETUP AND CONFIGURATION ESC Exit Current Provisi...

Страница 71: ...0005 Intel R ME v11 0 0 1205 Copyright C 2003 15 Intel Corporation All Rights Reserved INTEL R REMOTE SETUP AND CONFIGURATION ESC Exit Current Provisioning Mode Provisioning Record Provisioning Server IPV4 IPV6 _ Provisioning Server FQDN _ RCFG TLS PKI Move Highlight Enter Select Entry Esc Exit 35 In the Intel R Remote Configuration menu select Remote Configuration then press Enter select Enabled ...

Страница 72: ...ve Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Active Default Default Default Default Default Default Default Default Default Default Default Default Default Default Default Default Default Default SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 Hash Name Activ...

Страница 73: ... Management Engine BIOS Extension v11 0 0 0005 Intel R ME v11 0 0 1205 Copyright C 2003 15 Intel Corporation All Rights Reserved MAIN MENU Intel R ME General Settings Intel R AMT Configuration MEBx Exit Exit Move Highlight Enter Select Entry Esc Exit 65535 40 In the Intel R AMT Power Control menu select Intel R AMT ON in Host Sleep States then press Enter Select an option then press Enter Intel R ...

Страница 74: ...properly attached to the monitor and the system s display adapter 4 Adjust the brightness of the display by turning the monitor s brightness control knob The picture seems to be constantly moving 1 The monitor has lost its vertical sync Adjust the monitor s vertical sync 2 Move away any objects such as another monitor or fan that may be creating a magnetic field around the display 3 Make sure your...

Страница 75: ...l port that is working and configured correctly If the serial device does not work either the cable or the serial device has a problem If the serial device works the problem may be due to the onboard I O or the address setting 4 Make sure the COM settings and I O address are configured correctly Keyboard Nothing happens when a key on the keyboard was pressed 1 Make sure the keyboard is properly co...