www.dfi .com
41
Chapter 3 BIOS Setup
Chapter 3
Security
TPM Availability
Set the TPM availability.
TPM Operation
Enable or disable the storage and endorsement hierarchy. This option will
automatically return to No-Operation.
Clear TPM
Remove all TPM context associated with a specific owner.
Set Supervisor Password
Set the supervisor’s password and the length of the password must be greater than
one character.
Set All Hdd Password
Set all HDD password and suggest the length of password greater than one character.
This item can be displayed when any security mode of HDD is not Lock.
Set All Master Hdd Password
Set all master HDD password and suggest the length of password greater than one
character. This item can be displayed when any security mode of HDD is not Lock.
When Hidden, don’t ex-
poses TPM to 0
Current TPM Device
TPM State
TPM Availability
TPM Operation
Clear TPM
Supervisor Password
Set Supervisor Password
Set All Hdd Password
Set All Master Hdd Password
Storage Password Setup Page
Main
Advanced
F1
Help
↑
/
↓
Select Item
F5/F6
Change Values
F9
Setup Defaults
Esc
Exit
←
/
→
Select Item
Enter
Select
SubMenu
F10
Save and Exit
InsydeH20 Setup Utility
Security
Boot
Exit
Rev. 5.0
<TPM 1.2>
Enabled, Activated and Owned
<Available>
<No Operation>
[ ]
Not installed
TMP Availability
Available
Hidden
PC Health Status
This field only displays the PC health status.
PC Health Status
Voltage
VCORE
5V
+12V
VDDQ
VBAT
3VSB
Temperature
System (
o
C/
o
F)
CPU (
o
C/
o
F)
Fan Speed
SYS FAN
CPU FAN
SYS FAN 2
Advanced
F1
Help
↑
/
↓
Select Item
F5/F6
Change Values
F9
Setup Defaults
Esc
Exit
←
/
→
Select Item
Enter
Select
SubMenu
F10
Save and Exit
InsydeH20 Setup Utility
Rev. 5.0
1.120 V
5.056 V
11.880 V
1.200 V
3.056 V
3.312 V
37.0 C/ 98.6 F
44.5 C/ 112.1 F
0 RPM
1778 RPM
0 RPM
Enable/Disable Smart Fan
SYS Smart Fan Control
Fix Fan Speed Count
CPU Smart Fan Control
Fix Fan Speed Count
SYS Smart Fan 2 Control
Fix Fan Speed Count
COM Port 1
Base I/O Address
Interrupt
RS485 Auto Flow
COM Port 2
Base I/O Address
Interrupt
RS485 Auto Flow
COM Port 3
Base I/O Address
Interrupt
COM Port 4
Base I/O Address
Interrupt
COM Port 5
Base I/O Address
Interrupt
Advanced
F1
Help
↑
/
↓
Select Item
F5/F6
Change Values
F9
Setup Defaults
Esc
Exit
←
/
→
Select Item
Enter
Select
SubMenu
F10
Save and Exit
InsydeH20 Setup Utility
Rev. 5.0
<Disable>
[50]
<Disable>
[50]
<Disable>
[50]
<Enable>
<3F8>
<IRQ4>
<Disable>
<Enable>
<2F8>
<IRQ3>
<Disable>
<Enable>
<3E8>
<IRQ4>
<Enable>
<2E8>
<IRQ3>
<Enable>
<2E0>
<IRQ4>
Note:
SYS Smart Fan, Fan2 and CPU Smart Fan Control can be switched to <Disable>.
When they are disabled, it will enable "Fix Fan Speed Count".