MDP156
15.6” Healthcare Display
User’s Manual
A-605-M-2034
Страница 1: ...MDP156 15 6 Healthcare Display User s Manual A 605 M 2034...
Страница 2: ...CC and DOC Statement on Class B This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC rules These limits are designed to provid...
Страница 3: ...notices for use in the healthcare applications 11 Guidance and manufacturer s declaration electromagnetic emissions 12 Guidance and manufacturer s declaration electromagnetic immunity 12 Recommended s...
Страница 4: ...devices even before installing them in your system unit Static electrical discharge can damage computer components without causing any signs of physical damage You must take extra care in han dling t...
Страница 5: ...dapter Power Cord VGA Cable HDMI Cable USB Cable for Touch Optional Items Cable Clamp x 3 pcs VESA Desk Stand The main body and accessories in the package may not come similar to the information liste...
Страница 6: ...operation Mechanical Specification Mounting VESA Mount 75 x 75 mm 100 x 100 mm 200 x 100 mm VESA Screws M4x4L 75x75mm 100 x 100mm flat head Dimensions W x H x D 387 8 x 232 9 x 38 45 mm Housing Back c...
Страница 7: ...to be played through the monitor speak ers 4 HDMI Transmits and protects copyrighted digital video and audio Example An HD tuner to an HD ready TV 5 VGA RGB Transmits video from a PC to a monitor Exam...
Страница 8: ...ews to fix the desk stand to VESA holes on the back cover of the device Important The picture is for demonstration purposes only VESA Mount accessories are not supplied by default Connecting Periphera...
Страница 9: ...To turn off the device please disconnect the power cord from an electric outlet Important To fully disengage the power please disconnect the input plug from the ac outlet To avoid risk of electric sh...
Страница 10: ...cles trains high volt age lines or fluorescent lamps Bad color Color density or tint control may not be adjusted properly See the adjusted value of image Image appears and disappears Input may not be...
Страница 11: ...n shall be addressed to the authorized representative For any service or guarantee matters please refer to the ad dresses provided in the separate service or guarantee documents X Important safeguards...
Страница 12: ...c dis charge ESD IEC 61000 4 2 8 kV contact 15 kV air 8 kV contact 15 kV air Floors should be wood concrete or ce ramic tile If floors are covered with synthetic material the relative humidity should...
Страница 13: ...by an electromagnetic site survey A should be less than the compli ance level in each frequency range B Interference may occur near equipment marked with following symbol NOTE 1 At 80 MHz and 800 MHz...
Страница 14: ...the patient to come into contact at the same time Grounding reliability can only be achieved when the equipment is connected to an equiva lent receptacle marked Hospital Only or Hospital Grade X Insta...
Страница 15: ...ages for extended periods or using the unit repeatedly in a high temperature high humidity environments may cause image smearing burn in areas of which brightness is permanently changed lines or a dec...
Страница 16: ...each single failed Product that is returned for servicing repair reworking or failure investigation to Seller or to the Authorized Service Provider At least one adhesive yellow label shall be attached...