7 6
3
BIOS Setup
PWRON After PWR-Fail
Off
When power returns after an AC power failure,
the system’s power is off. You must press the
Power button to power-on the system.
On
When power returns after an AC power failure,
the system will automatically power-on.
RTC Alarm Resume
Enabled
When Enabled, you can set the date and time
you would like the Soft Power Down (Soft-Off)
PC to power-on in the “Date (of Month)” and
“Resume Time” fields. However, if the system is
being accessed by incoming calls or the network
(Resume On Ring/LAN) prior to the date and
time set in these fields, the system will give prior-
ity to the incoming calls or network.
Disabled
Disables the automatic power-on function. (de-
fault).
Date (of Month)
0
The system will power-on everyday according to the
time set in the “Time (hh:mm:ss) Alarm” field.
1-31
Select a date you would like the system to power-on.
The system will power-on on the set date, and time set
in the “Time (hh:mm:ss) Alarm” field.
Resume Time (hh:mm:ss)
This is used to set the time you would like the system to power-on.
If you want the system to power-on everyday as set in the “Date
(of Month) ” field, the time set in this field must be later than the
time of the RTC set in the Standard CMOS Features submenu.