Chapter 3 Hardware Installation

13

Chapter 3

COM Express Connectors

A1

GND (FIXED)

B1

GND (FIXED)

A56   PCIE_TX4-

B56   PCIE_RX4- 

A2

GBE0_MDI3-

B2

GBE0_ACT#

A57   GND  

B57   GPO2  

A3

GB

B3

LPC_FRAME#

A58   P

B58   P

A4

GBE0_LINK100#

B4

LPC_AD0

A59   PCIE_TX3-

B59   PCIE_RX3-

A5

GBE0_LINK1000# B5

LPC_AD1

A60   GND (FIXED)

B60   GND (FIXED)

A6

GBE0_MDI2-

B6

LPC_AD2

A61   P  

B61   P  

A7

GB

B7

LPC_AD3

A62   PCIE_TX2-  

B62   PCIE_RX2-  

A8

GBE0_LINK#

B8

LPC_DRQ0#

A63   GPI1  

B63   GPO3  

A9

GBE0_MDI1-

B9

LPC_DRQ1#

A64

P

B64

P

A10

GB

B10

LPC_CLK

A65

PCIE_TX1-

B65

PCIE_RX1-

A11

GND (FIXED)

B11

GND (FIXED)

A66

GND

B66

WAKE0#

A12

GBE0_MDI0-

B12

PWRBTN#

A67

GPI2

B67   WAKE1#

A13

GB

B13

SMB_CK

A68

P

B68   P  

A14

GBE0_CTREF

B14

SMB_DAT

A69

PCIE_TX0-

B69   PCIE_RX0-  

A15

SUS_S3#

B15

SMB_ALERT#

A70

GND (FIXED)

B70   GND (FIXED)

A16

S

B16

S

A71

B71     

A17

SATA0_TX-

B17

SATA1_TX-

A72

LVDS_A0-

B72   LVDS_B0-  

A18

SUS_S4#

B18

SUS_STAT#

A73

B73     

A19

S

B19

S

A74

LVDS_A1-  

B74   LVDS_B1-  

A20

SATA0_RX-

B20

SATA1_RX-

A75   

B75     

A21

GND (FIXED)

B21

GND (FIXED)

A76   LVDS_A2-

B76   LVDS_B2-  

A22

S

B22

NA

A77   LVDS_VDD_EN  

B77     

A23

SATA2_TX-

B23

NA

A78   

B78   LVDS_B3-  

A24

SUS_S5#

B24

PWR_OK

A79   LVDS_A3-

B79   LVDS_BKLT_EN  

A25

S

B25

NA

A80   GND (FIXED)  

B80   GND (FIXED)  

A26

SATA2_RX-

B26

NA

A81   LV  

B81   LV  

A27

BATLOW#

B27

WDT

A82

LVDS_A_CK-

B82

LVDS_B_CK-

A28

(S)ATA_ACT#

B28

NA

A83

LVDS_I2C_CK

B83

LVDS_BKLT_CTRL

A29

AC/HDA_SYNC

B29

AC/HDA _SDIN1

A84

LVDS_I2C_DAT

B84

VCC_5V_SBY

A30

AC/HDA _RST#

B30

AC/HDA _SDIN0

A85

GPI3

B85

VCC_5V_SBY

A31

GND (FIXED)

B31

GND (FIXED)

A86

RSVD

B86

VCC_5V_SBY

A32

AC/HDA _BITCLK B32

SPKR

A87

RSVD

B87

VCC_5V_SBY

A33

AC/HDA _SDOUT B33

I2C_CK

A88

PCIE0_

B88

BIOS_DIS1#

A34

BIOS_DIS0#

B34

I2C_DAT

A89

PCIE0_CLK_REF-

B89

VGA_RED

A35

THRMTRIP#

B35

THRM#

A90

GND (FIXED)

B90

GND (FIXED)

A36

USB6-

B36

USB7-

A91

SPI_POWER

B91

VGA_GRN

A37

USB6+

B37

USB7+

A92

SPI_MISO

B92

VGA_BLU

A38

USB_6_7_OC#

B38

USB_4_5_OC#

A93

GPO0

B93

VGA_HSYNC

A39

USB4-

B39

USB5-

A94

SPI_CLK

B94

VGA_VSYNC

A40

USB4+

B40

USB5+

A95

SPI_MOSI

B95

VGA_I2C_CK

A41

GND (FIXED)

B41

GND (FIXED)

A96

NA

B96

VGA_I2C_DAT

A42

USB2-

B42

USB3-

A97

TYPE10#

B97

SPI_CS#

A43

USB2+

B43

USB3+

A98

SER0_TX

B98

RSVD

A44

USB_2_3_OC#

B44

USB_0_1_OC#

A99

SER0_RX

B99

RSVD

A45

USB0-

B45

USB1-

A100 GND (FIXED)

B100 GND (FIXED)

A46

USB0+

B46

USB1+

A101 SER1_TX

B101 FAN_PWMOUT

A47

VCC_RTC

B47

EXCD1_PERST#

A102 SER1_RX

B102 FAN_TACHIN

A48

EXCD0_PERST#

B48

EXCD1_CPPE#

A103 LID#

B103 SLEEP#

A49

EXCD0_CPPE#

B49

SYS_RESET#

A104 VCC_12V

B104 VCC_12V

A50

LPC_SERIRQ

B50

CB_RESET#

A105 VCC_12V

B105 VCC_12V

A51

GND (FIXED)

B51

GND (FIXED)

A106 VCC_12V

B106 VCC_12V

A52   P

B52   P

A107 VCC_12V

B107 VCC_12V

A53   PCIE_TX5-

B53   PCIE_RX5-

A108 VCC_12V

B108 VCC_12V

A54   GPI0  

B54   GPO1  

A109 VCC_12V

B109 VCC_12V

A55   P

B55   P

A110 GND (FIXED)

B110 GND (FIXED)

Row A

Row B

Row A

Row B

C1

GND (FIXED)

D1

GND (FIXED)

C56   NA

D56   NA

C2

GND

D2

GND

C57   TYPE1#

D57   TYPE2#

C3

USB_SSRX0-

D3

USB_SSTX0-

C58   NA

D58   NA

C4

US

D4

US

C59   NA

D59   NA

C5

GND

D5

GND

C60   GND (FIXED)   D60   GND (FIXED)  

C6

USB_SSRX1-

D6

USB_SSTX1-

C61   NA

D61   NA

C7

US

D7

US

C62   NA

D62   NA

C8

GND

D8

GND

C63   RSVD

D63

RSVD

C9

USB_SSRX2-

D9

USB_SSTX2-

C64

RSVD

D64

RSVD

C10

US

D10

US

C65

NA

D65

NA

C11

GND (FIXED)

D11

GND (FIXED)

C66

NA

D66

NA

C12

USB_SSRX3-

D12

USB_SSTX3-

C67   RSVD

D67

GND

C13

US

D13

US

C68   NA

D68

NA

C14

GND

D14

GND

C69   NA

D69

NA

C15

NA

D15

DDI1_CTRL

C70   GND (FIXED)   D70   GND (FIXED) 

C16

NA

D16

DDI1_CTRLDATA_AUX- C71   NA

D71   NA

C17

RSVD

D17

RSVD

C72   NA

D72

NA

C18

RSVD

D18

RSVD

C73   GND

D73   GND

C19

P

D19

P

C74   NA

D74   NA

C20

PCIE_RX6-

D20

PCIE_TX6-

C75   NA

D75   NA

C21

GND (FIXED)

D21

GND (FIXED)

C76   GND  

D76

GND  

C22

P

D22

P

C77   RSVD

D77   RSVD

C23

PCIE_RX7-

D23

PCIE_TX7-

C78   NA

D78   NA

C24

DDI1_HPD

D24

RSVD

C79   NA

D79   NA

C25

NA

D25

RSVD

C80   GND (FIXED)   D80   GND (FIXED) 

C26

NA

D26

DDI

C81   NA

D81   NA

C27

RSVD

D27

DDI1_PAIR0-

C82

NA

D82

NA

C28

RSVD

D28

RSVD

C83

RSVD

D83

RSVD

C29

NA

D29

DDI

C84

GND

D84

GND

C30

NA

D30

DDI1_PAIR1-

C85

NA

D85

NA

C31

GND (FIXED)

D31

GND (FIXED)

C86

NA

D86

NA

C32

DDI2_CTRL

D32

DDI

C87

GND

D87

GND

C33

DDI2_CTRLDATA_AUX-

D33

DDI1_PAIR2-

C88

NA

D88

NA

C34

DDI2_DDC_AUX_SEL

D34

DDI1_DDC_AUX_SEL

C89

NA

D89

NA

C35

RSVD

D35

RSVD

C90   GND (FIXED)   D90   GND (FIXED)  

C36

NA

D36

DDI

C91

NA

D91

NA

C37

NA

D37

DDI1_PAIR3-

C92

NA

D92

NA

C38

NA

D38

RSVD

C93

GND

D93

GND

C39

NA

D39

DDI

C94

NA

D94

NA

C40

NA

D40

DDI2_PAIR0-

C95

NA

D95

NA

C41

GND (FIXED)

D41

GND (FIXED)

C96

GND

D96

GND

C42

NA

D42

DDI

C97

RSVD

D97

RSVD

C43

NA

D43

DDI2_PAIR1-

C98

NA

D98

NA

C44

NA

D44

DDI2_HPD

C99

NA

D99

NA

C45

RSVD

D45

RSVD

C100   GND (FIXED)   D100   GND (FIXED)  

C46

NA

D46

DDI

C101 NA

D101 NA

C47

NA

D47

DDI2_PAIR2-

C102 NA

D102 NA

C48

RSVD

D48

RSVD

C103 GND

D103 GND

C49

NA

D49

DDI

C104 VCC_12V

D104 VCC_12V

C50

NA

D50

DDI2_PAIR3-

C105 VCC_12V

D105 VCC_12V

C51

GND (FIXED)

D51

GND (FIXED)

C106 VCC_12V

D106 VCC_12V

C52   NA

D52   NA

C107 VCC_12V

D107 VCC_12V

C53   NA

D53   NA

C108 VCC_12V

D108 VCC_12V

C54   TYPE0#

D54   PEG_LANE_RV#

C109 VCC_12V

D109 VCC_12V

C55   NA

D55   NA

C110 GND (FIXED)

D110 GND (FIXED)

Row C

Row D

Row C

Row D

Содержание KU968

Страница 1: ...www dfi com Chapter 1 Introduction 1 KU968 COM Express Compact Module User s Manual A 456 M 2007...

Страница 2: ...M Express ModuleTM Base Specification http www picmg org FCC and DOC Statement on Class B This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Pa...

Страница 3: ...s 8 Specification Comparison Table 9 Chapter 3 Hardware Installation 10 Board Layout 10 System Memory 11 Connectors 12 CPU Fan Connector 12 COM Express Connectors 13 COM Express connectors Signal Disc...

Страница 4: ...You must take extra care in han dling them to ensure against electrostatic build up 1 To prevent electrostatic build up leave the system board in its anti static bag until you are ready to install it...

Страница 5: ...ted above This may differ in accordance with the sales region or models in which it was sold For more information about the standard package in your region please contact your dealer or sales represen...

Страница 6: ...DP resolution up to 4096x2304 60Hz Triple Displays VGA LVDS DDI DDI eDP DDI EXPANSION Interface 5 PCIe x1 or 4 PCIe x1 1 PCIe x4 or 3 PCIe x1 2 PCIe x2 support up to 5 devices and 8 lanes 1 x LPC 1 x...

Страница 7: ...pports 1 x VGA DDI DDI available upon request 1 x LVDS eDP eDP available upon request and 1 x DDI display interfaces Serial ATA Serial ATA is a storage interface that is compliant with SATA 1 0a speci...

Страница 8: ...Basic Compact Mini 74 20 80 00 91 00 121 00 151 00 Common for all Form Factors Extended only Basic only Compact only Compact and Basic only Mini only COM Express Module Standards The figure below sho...

Страница 9: ...NA A B LAN Port 0 1 1 1 A B Express Card Support 1 2 2 A B LPC Bus 1 1 1 A B SPI 1 2 1 A B SDIO muxed on GPIO 0 1 0 General Purpose I O 8 8 8 A B SMBus 1 1 1 A B I2C 1 1 1 A B Watchdog Timer 0 1 1 A B...

Страница 10: ...ation Board Layout Top View Bottom View iTE IT8528VG TPM optional DDR4 DDR4 DDR4 DDR4 SPI Flash BIOS Intel BGA 1356 Intel I219LM NXP PTN3460 Chrontel CH7517 CPU Fan 1 3 Standby Power LED COM Express C...

Страница 11: ...n is not available you can provide some ESD protection by wear ing an antistatic wrist strap and attaching it to a metal part of the system chassis If a wrist strap is unavailable establish and mainta...

Страница 12: ...l display the current speed of the cooling fan Refer to chapter 4 of the manual for more information 3 1 Sense 12V Ground COM Express Connectors The COM Express connectors are used to interface the KU...

Страница 13: ...SLEEP A49 EXCD0_CPPE B49 SYS_RESET A104 VCC_12V B104 VCC_12V A50 LPC_SERIRQ B50 CB_RESET A105 VCC_12V B105 VCC_12V A51 GND FIXED B51 GND FIXED A106 VCC_12V B106 VCC_12V A52 PCIE_TX5 B52 PCIE_RX5 A107...

Страница 14: ...acitor SATA0_RX A19 I SATA AC coupled on Module AC Coupling capacitor SATA0_RX A20 I SATA AC coupled on Module AC Coupling capacitor SATA1_TX B16 O SATA AC coupled on Module AC Coupling capacitor SATA...

Страница 15: ...hics transmit differential pairs 9 O PCIE AC coupled on Module PCI Express Graphics transmit differential pairs 8 I PCIE AC coupled off Module PCI Express Graphics receive differential pairs 5 O PCIE...

Страница 16: ...rs 0 1uF to Device DDI2_PAIR1 D42 Connect AC Coupling Capacitors 0 1uF to Device DDI2_PAIR1 D43 Connect AC Coupling Capacitors 0 1uF to Device DDI2_PAIR2 D46 Connect AC Coupling Capacitors 0 1uF to De...

Страница 17: ...D3 AC Coupling capacitor USB_SSRX0 C4 USB_SSRX0 C3 USB_SSTX1 D7 AC Coupling capacitor USB_SSTX1 D6 AC Coupling capacitor USB_SSRX1 C7 USB_SSRX1 C6 USB_SSTX2 D10 AC Coupling capacitor USB_SSTX2 D9 AC C...

Страница 18: ...resistor 33 to Carrier Board SPI Device SCK pin Clock from Module to Carrier SPI SPI_POWER A91 O 3 3V Suspend 3 3V Power supply for Carrier Board SPI sourced from Module nominally 3 3V The Module shal...

Страница 19: ...Description PWRBTN B12 I CMOS 3 3V Suspend 3 3V PU 10K to 3V3_DU_EC PU 4 7K to 3V3_SB A falling edge creates a power button event Power button events can be used to bring a system out of S5 soft off a...

Страница 20: ...Signal Pin Module Pin Type Pwr Rail Tolerance KU968 Carrier Board Description VCC_12V A104 A109 B104 B109 C104 C109 D104 D109 Power Primary power input 12V nominal All available VCC_12V pins on the c...

Страница 21: ...n of the thermal pad designed to contact the corresponding components that are on the KU968 Top View of the Heat Sink Important Remove the plastic covering from the thermal pads prior to mounting the...

Страница 22: ...oard 2 Press KU968 down firmly to seat it in the COM Express connectors of the carrier board Note The illustration above shows the pressing points of the module onto the carrier board Be careful when...

Страница 23: ...om Chapter 3 Hardware Installation 23 Chapter 3 3 Use the provided mounting screws to secure KU968 with heat sink to the carrie board The photo below shows the locations of the long mounting screws Lo...

Страница 24: ...g card designed for COM Express Compact modules to debug and display signals and codes of COM Express modules COMe LINK1 Bottom view Top view COMe DEBUG Connector COM Express Connectors 2 Connect the...

Страница 25: ...OMe LINK1 debug card onto the carrier board COMe LINK1 Carrier Board 4 Then use the instructions from the previous section to install SU968 and heat sink on the top of the COMe LINK1 debug card Screws...

Страница 26: ...ty does not require an operating system to run After you power up the system the BIOS message appears on the screen and the memory count begins After the memory test the message Press DEL to run setup...

Страница 27: ...tup Utility Security F1 Help Select Item F5 F6 Change Values F9 Setup Defaults Esc Exit Select Item Enter Select SubMenu F10 Save and Exit Project Name BIOS Version EC Version Processor Type CPUID CPU...

Страница 28: ...ing state Always Off Off except for trickle current to devices such as the power button Wake On RTC Automatically power the system on at a particular time every day from the Real time clock battery Wa...

Страница 29: ...InsydeH2O Setup Utility Rev 5 0 Video Configuration This section configures the video settings Primary Display Set the initial priority Internal Graphics Device Keep IGFX enabled or disabled based on...

Страница 30: ...olor depth configuration 18 Bit 24 Bit 36 Bit or 48 Bit LCD Panel Type Select LCD Panel Type 800x480 800x600 1024x768 1366x768 1280x1024 1920x1080 or 1920x1200 Backlight Type Select Backlight Type Nor...

Страница 31: ...ort 2 Port 0 Hot Plug Port 1 Hot Plug Port 2 Hot Plug Advanced F1 Help Select Item F5 F6 Change Values F9 Setup Defaults Esc Exit Select Item Enter Select SubMenu F10 Save and Exit InsydeH2O Setup Uti...

Страница 32: ...up Defaults Esc Exit Select Item Enter Select SubMenu F10 Save and Exit InsydeH2O Setup Utility Rev 5 0 Control the PCI Express Root Port PCI Express Root Port 1 PCIe Speed Hot Plug Disabled Advanced...

Страница 33: ...tem F5 F6 Change Values F9 Setup Defaults Esc Exit Select Item Enter Select SubMenu F10 Save and Exit InsydeH2O Setup Utility Rev 5 0 Disabled Me Fw Image Re Flash This field is used to enable or disa...

Страница 34: ...anagement Technology Un Configure ME This field is used to enable or disable to un configure ME with resetting MEBX pass word to default Debug Configuration This section configures debug setting Enabl...

Страница 35: ...Enable User Configuration COM Port 1 Base I O Address Interrupt COM Port 2 Base I O Address Interrupt WDT CPU Smart Fan Control Boundary 1 Boundary 2 Boundary 3 Boundary 4 Fan Speed Count 1 Fan Speed...

Страница 36: ...s the PC health status PC Health Status Voltage VBAT VCORE VDDQ 5V 12V Temperature CPU o C o F Fan Speed SYS FAN CPU FAN Advanced F1 Help Select Item F5 F6 Change Values F9 Setup Defaults Esc Exit Sel...

Страница 37: ...ar like below Enable Console Redirec tion Function Console Redirection Setup Console Serial Redirect Terminal Type Baud Rate Data Bits Parity Stop Bits Flow Control COMA Enable VT 100 115200 N81 COMB...

Страница 38: ...l setting When enabled the global set ting setting of the COM port will be the same as those in Console Redirection section When disabled the global setting setting of the COM port can be configured i...

Страница 39: ...oot Selects Power on state for Numlock Numlock Boot Type Network Stack PXE Boot capability USB Boot Quiet Boot Main Advanced F1 Help Select Item F5 F6 Change Values F9 Setup Defaults Esc Exit Select I...

Страница 40: ...ress Enter to exit the system setup without saving your changes Save Setting to file Select this option to save BIOS configuration settings to a USB flash device Restore Setting from file This field w...

Страница 41: ...rom this system board and used on another system board of the same model 2 The BIOS SPI ROM on this system board must be the original equipment from the factory and cannot be used to replace one which...

Страница 42: ...el chipset can be recognized and configured properly in the system To install the utility download KU968 Chipset Driver zip file at our website 1 Setup is ready to install the utility Click Next 2 Rea...

Страница 43: ...driver and the system rebooted the screen will turn blank for 1 to 2 minutes while WinSAT is running before the Windows 10 desktop appears The blank screen period is the time Windows is testing the gr...

Страница 44: ...sh Restarting the system will allow the new software installation to take effect 1 Setup is ready to install the driver Click Next Intel LAN Drivers To install the driver download KU968 LAN Driver zip...

Страница 45: ...all to begin the installation 6 After completing installa tion click Finish Intel Management Engine Drivers To install the driver download KU968 MEI Driver zip file at our website 1 Setup is ready to...

Страница 46: ...Rapid Storage Technology The Intel Rapid Storage Technology is a utility that allows you to monitor the current status of the SATA drives It enables enhanced performance and power management for the...

Страница 47: ...m requirements and installa tion information then click Next 5 Confirm the installation and click Next 4 Click Next to install to the default folder or click Change to choose another destination folde...

Страница 48: ...he reader download KU968 Driver Package iso file at our website Click Adobe Acrobat Reader 9 3 1 Click Next to install or click Change Destination Folder to select another folder 2 Click Install to be...

Страница 49: ...d KU968 SIO Driver zip file at our website 1 Setup is ready to install the driver Click Next 2 Read the license agreement care fully Click I accept the terms in the Li cense Agreement then click Next...

Страница 50: ...Chapter 5 www dfi com Chapter 5 Supported Software 50 5 Setup is now installing the driver 6 Click Finish...

Страница 51: ...lerant and provides better hard drive performance and more storage capacity RAID Level Min Drives Protection Description RAID 0 2 None Data striping without redundancy RAID 1 2 Single Drive Failure Di...

Страница 52: ...AID volumes To set the boot type enter the Insyde BIOS and go to Boot Boot Type 1 Go to the Advanced menu of the Insyde BIOS and select Device Manager Device Manager Setting ACPI Configuration CPU Con...

Страница 53: ...nt create delete migrate from within the operating system It will also display useful SATA device and RAID volume information The user interface tray icon service and monitor service allow you to moni...

Страница 54: ...figuration Console Redirection Main Advanced F1 Help Select Item F5 F6 Change Values F9 Setup Defaults Esc Exit Select Item Enter Select SubMenu F10 Save and Exit InsydeH2O Setup Utility Security Boot...

Страница 55: ...y Security Boot Rev 5 0 Exit MEBX Configuration Set ting ACPI Configuration CPU Configuration Video Configuration Audio Configuration SATA Configuration USB Configuration PCI Express Configuration ME...

Страница 56: ...ion v11 0 0 0010 Intel R ME v11 8 50 3434 Copyright C 2003 16 Intel Corporation All Rights Reserved MAIN MENU MEBx Login Intel R ME General Settings Intel R AMT Configuration MEBx Exit Intel R ME Pass...

Страница 57: ...provided under Intel R ME Password then press Enter Intel R Management Engine BIOS Extension v11 0 0 0010 Intel R ME v11 8 50 3434 Copyright C 2003 16 Intel Corporation All Rights Reserved INTEL R ME...

Страница 58: ...Control Disabled Enabled INTEL R AMT CONFIGURATION Move Highlight Enter Complete Entry Esc Discard Changes 14 In the Intel R AMT Configuration menu select SOL Storage Redirection KVM then press Enter...

Страница 59: ...bled Move Highlight Enter Complete Entry Esc Discard Changes 18 Select KVM Feature Selection then press Enter Select Enabled or Disabled then press Enter Intel R Management Engine BIOS Extension v11 0...

Страница 60: ...ose to use a password only during setup and configuration or to use a pass word anytime the system is being accessed Intel R Management Engine BIOS Extension v11 0 0 0010 Intel R ME v11 8 50 3434 Copy...

Страница 61: ...E SETTINGS Host Name Domain Name Shared Dedicated FQDN Dynamic DNS Update 26 Select Domain Name then press Enter Enter the computer s domain name then press Enter Intel R Management Engine BIOS Extens...

Страница 62: ...Copyright C 2003 16 Intel Corporation All Rights Reserved Move Highlight Enter Select Entry Esc Exit TCP IP SETTINGS Wired LAN IPV4 Configuration 29 Select Periodic Update Interval then press Enter E...

Страница 63: ...0 Preferred DNS Address 0 0 0 0 Alternate DNS Address 0 0 0 0 Enter Complete Entry Esc Discard Changes 34 Select Subnet Mask Address then press Enter Enter address then press Enter Intel R Management...

Страница 64: ...2003 16 Intel Corporation All Rights Reserved WIRED LAN IPV4 CONFIGURATION DHCP Mode Disabled IPV4 Address 0 0 0 0 Subnet Mask Address 0 0 0 0 Default Gateway Address 0 0 0 0 Preferred DNS Address 0...

Страница 65: ...nt Provisioning Mode Provisioning Record Provisioning Server IPV4 IPV6 _ Provisioning Server FQDN _ RCFG TLS PKI Provisioning Mode PKI 42 In the Intel R Remote Setup And Configuration menu select Prov...

Страница 66: ...INTEL R REMOTE CONFIGURATION Start Configuration Move Highlight Enter Select Entry Esc Exit This will activate Remote Configuration Continue Y N 46 Press Esc until you return to the Intel R Remote Se...

Страница 67: ...SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 Hash Name Active Default Algorithm VeriSign Class 3 VeriSign Class 3 Go Daddy Cla...

Отзывы: