background image

www.d

fi

 .com

38

Chapter 3 BIOS Setup

Chapter 3

PCI Express Configuration

This section configures settings relevant to PCI Express root ports.

PEG PCI Express Port set-
ting

PCIE 1

PCIE 2

PCIE 3

PCIE 4

M.2

Intel I210AT

Intel I219LM

Advanced

F1   

Help             

  

/

    

Select Item                  

F5/F6 

Change Values                 

F9   

Setup Defaults

Esc  

Exit             

 

/

  

Select Item                  

Enter 

Select 

 SubMenu             

F10 

Save and Exit

InsydeH2O Setup Utility

Rev. 5.0

Enable or Disable the Root 
Port

PCIE 1

PCIe Speed
Hot Plug                                                      <Disabled>

Advanced

F1   

Help             

  

/

    

Select Item                  

F5/F6 

Change Values                 

F9   

Setup Defaults

Esc  

Exit             

 

/

  

Select Item                  

Enter 

Select 

 SubMenu             

F10 

Save and Exit

InsydeH2O Setup Utility

Rev. 5.0

                     <Enabled>

                     <AUTO>

PCIE 1 to PCIE 4 and M.2

This field is used to enable or disable the PCI Express Root Port.

PCIe Speed 

Select the speed of the PCI Express Root Port: Auto, Gen1, Gen2 or Gen3.

Hot Plug

This field is used to enable or disable the PCI Express Hot Plug.

Control the PCI Express 
Root Port.

Intel I210AT

                                                    

Advanced

F1   

Help             

  

/

    

Select Item                  

F5/F6 

Change Values                 

F9   

Setup Defaults

Esc  

Exit             

 

/

  

Select Item                  

Enter 

Select 

 SubMenu             

F10 

Save and Exit

InsydeH2O Setup Utility

Rev. 5.0

                     <Enabled>

                    

Intel I210AT

This field is used to enable or disable the PCI Express Root Port 19 settings.

Control the PCI Express 
Root Port.

Intel I219LM

                                                   

Advanced

F1   

Help             

  

/

    

Select Item                  

F5/F6 

Change Values                 

F9   

Setup Defaults

Esc  

Exit             

 

/

  

Select Item                  

Enter 

Select 

 SubMenu             

F10 

Save and Exit

InsydeH2O Setup Utility

Rev. 5.0

                     <Enabled>

                    

Intel I219LM

This field is used to enable or disable the PCI Express Root Port 12 settings.

Содержание KD631-C236/Q170

Страница 1: ...1 KD631 C236 Q170 ATX Industrial Motherboard User s Manual A47800826 ...

Страница 2: ...C Statement on Class B This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reason able protection against harmful interference when the equipment is operated in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and ...

Страница 3: ... 19 PS 2 Keyboad Mouse Port 19 COM Serial Ports 20 Graphics Interfaces 21 RJ45 LAN Ports 22 USB Ports 22 Audio 23 I O Connectors 24 SATA Serial ATA Connectors 24 Digital I O Connector 24 Cooling Fan Connectors 25 Power Connectors 25 Chassis Intrusion Connector 26 Front Panel Connector 26 Standby Power LED 27 Expansion Slots 27 S PDIF Connector 28 Battery 28 SMBus Connector 29 LAN LED Connector 29 ...

Страница 4: ...xtra care in han dling them to ensure against electrostatic build up 1 To prevent electrostatic build up leave the system board in its anti static bag until you are ready to install it 2 Wear an antistatic wrist strap 3 Do all preparation work on a static free surface 4 Hold the device only by its edges Be careful not to touch any of the components contacts or connections 5 Avoid touching the pins...

Страница 5: ... 2 x COM ports Serial ATA data cable Length 500mm W LOCK Thermal solution For 35W Height 37 3mm Thermal solution For 65W Height 72 8mm Thermal solution For 95W Height 69 3mm For KD631 C236 LPC EXT RS232 module 4 x RS232 ports LPC EXT RS485 module 4 x RS485 ports The board and accessories in the package may not come similar to the information listed above This may differ in accordance to the sales ...

Страница 6: ...ts Optane memory technology AUDIO Audio Codec Realtek ALC888S VD2 GR ETHERNET Controller 1 x Intel I210AT PCIe 10 100 1000Mbps 1 x Intel I219LM PCIe with iAMT11 0 10 100 1000Mbps only Xeon and Core i7 i5 support iAMT REAR I O Ethernet 2 x GbE RJ 45 USB 4 x USB 3 0 2 x USB 2 0 Serial 1 x RS 232 422 485 RS 232 w power DB 9 PS 2 1 x PS 2 mini DIN 6 Display 1 x VGA 1 x DVI I DVI D signal 1 x HDMI Audi...

Страница 7: ...mission Audio The Realtek ALC888S VD2 GR audio codec provides 5 1 channel High Definition audio output Important The 5V_standby power source of your power supply must support 720mA Wake On USB This function allows you to use a USB keyboard or USB mouse to wake up a system from the S3 STR Suspend To RAM state RTC Timer The RTC installed on the system board allows your system to automatically power ...

Страница 8: ...ning at a maximum transmis sion speed of up to 5 Gbit s 625 MB s and is faster than USB 2 0 480 Mbit s or 60 MB s and USB 1 1 12Mb s USB 3 0 reduces the time required for data transmission reduces power consumption and is backward compatible with USB 2 0 It is a marked improvement in device transfer speeds between your computer and a wide range of simultaneously accessible external Plug and Play p...

Страница 9: ...elect JP6 12V Power 4 8 1 5 2 COM 1 RS232 Power Select JP8 COM 1 RS232 422 485 Select JP7 Intel I219LM PS 2 KB MS USB 6 USB 5 USB 2 0 COM 1 VGA M 2 2 9 10 1 Front Audio 19 DVI I DVI D signal HDMI Line in opt Line out Mic in 1 29 32 30 31 29 32 30 31 1 2 8 7 2 22 1 2 1 S1 S3 210 9 2 10 9 Battery 19 System Memory Standby Power LED Features Important Electrostatic discharge ESD can damage your board ...

Страница 10: ...pletely different However we highly recommend using identical DIMMs Not all slots need to be populated Dual Channel DIMMs of the same memory configuration are on different channels Important You can populate either Channel A or Channel B first Note The system board used in the following illustrations may not resemble the actual board These illustrations are for reference only 1 Make sure the PC an...

Страница 11: ...ep the protective cap RMA requests will be accepted and pro cessed only if the LGA 1151 socket comes with the protective cap Note The system board used in the following illustrations may not resemble the actual board These illustrations are for reference only 7 Seat the module vertically pressing it down firmly until it is completely seated in the socket 6 Grasping the module by its edges position...

Страница 12: ...n powered down 2 Disconnect all power cords and cables 3 Locate the LGA 1151 CPU socket on the system board 4 Unlock the socket by push ing the load lever down moving it sideways until it is released from the reten tion tab then lift the load lever up Retention tab Load lever 6 Remove the protective cap from the CPU socket The cap is used to protect the CPU socket against dust and harmful particle...

Страница 13: ... on the CPU must align with the corner of the CPU socket shown on the photo The CPU s notch will prop erly fit into the socket s alignment key Alignment key Alignment key Gold triangular mark 8 Close the load plate then push the load lever down While closing the load plate make sure the front edge of the load plate slides under the retention knob Retention knob 9 Hook the load lever under the rete...

Страница 14: ...s a patch of thermal paste on its underside Peel the strip that covers the paste before you place the fan heat sink on top of the CPU 2 Place the heat sink on top of the CPU The 4 push pins around the heat sink which are used to secure the heat sink onto the sys tem board must match the 4 mounting holes around the socket Mounting hole 3 Orient the heat sink such that the CPU fan s cable is nearest...

Страница 15: ...x USB 3 0 USB 2 0 PCIe x1 I210AT MDI USB 3 0 USB 2 0 PCIe x1 I219LM MDI LAN 1x USB 3 0 2x PS 2 KB MS USB 2 0 2x USB 2 0 LPC Channel A 2133 2400MHz Channel B 2133 2400MHz HD Audio Line out Line in Mic in S PDIF LPC EXT RS232 RS485 Module Opt Q170 DMI 3 0 PCIe x16 SATA 3 0 DDR4 DIMM 2x DDR4 DIMM 2x Core i7 i5 i3 PCIe x16 slot 2x 1 x16 or 2 x8 signal SATA 5x PCIe x4 2x PCIe x4 Digital I O 8 bit SMBus...

Страница 16: ...ngs Clear CMOS Data If you encounter the followings a CMOS data becomes corrupted b You forgot the supervisor or user password you can reconfigure the system with the default values stored in the ROM BIOS To load the default values stored in the ROM BIOS please follow the steps below 1 Power off the system and unplug the power cord 2 Set JP9 pins 2 and 3 to On Wait for a few seconds and set JP9 ba...

Страница 17: ...ance to JP1 The pin functions of the COM ports will vary according to the jumpers setting 10 2 1 9 1 3 5 2 4 6 1 3 5 2 4 6 1 3 5 2 4 6 2 4 6 1 3 5 JP5 COM 1 JP1 COM 2 COM 1 COM 2 1 2 3 4 5 6 7 8 9 1 2 On RS232 default 3 4 On RS422 Full Duplex 5 6 On RS485 2 4 6 1 3 5 2 4 6 1 3 5 2 4 6 1 3 5 Pin RS232 RS422 Full Duplex RS485 1 DCD RXD DATA 2 RD RXD DATA 3 TD TXD N C 4 DTR TXD N C 5 GND GND GND 6 DS...

Страница 18: ...er The pin functions of COM 1 and COM 2 will vary according to JP8 s and JP4 s setting respectively COM 1 COM 2 10 2 1 9 COM 1 COM 2 1 2 3 4 5 6 7 8 9 Pin RS232 RS232 with power 1 DCD 12V 2 RD RD 3 TD TD 4 DTR DTR 5 GND GND 6 DSR DSR 7 RTS RTS 8 CTS CTS 9 RI 5V JP8 COM 1 1 3 RI 2 4 DCD On RS232 default 3 5 5V 4 6 12V On RS232 with power JP4 COM 2 2 4 6 1 3 5 2 4 6 1 3 5 1 3 RI 2 4 DCD On RS232 def...

Страница 19: ...2 mouse port uses IRQ12 Wake On PS 2 Keyboard Mouse The Wake On PS 2 Keyboard Mouse function allows you to use the PS 2 keyboard or PS 2 mouse to power on the system To use this function BIOS Setting Configure the wake up function of PS 2 keyboard mouse in the Advanced menu ACPI Con figuration submenu of the BIOS Refer to the chapter 3 for more information The rear panel I O ports consist of the f...

Страница 20: ... 32 30 31 1 2 8 7 2 22 1 2 1 S1 S3 210 9 2 10 9 Battery 19 COM 2 RS232 422 485 COM 2 COM 3 COM 4 COM 5 COM 6 10 2 1 9 The pin functions of COM 1 port will vary according to setting of JP5 JP6 JP7 and JP8 Refer to COM1 COM2 RS232 422 485 Select and COM1 COM2 RS232 Power Select in this chapter for more information The pin functions of COM 2 port will vary according to setting of JP1 JP2 JP3 and JP4 ...

Страница 21: ... or LCD TV This port supports DVI D signal only Connect the display device s cable connector to the port After you plug the cable connector into the port gently tighten the cable screws to hold the connector in place HDMI Port The HDMI port which carries both digital audio and video signals is used to connect a LCD monitor or digital TV that has the HDMI port DVI I DVI D signal HDMI 1 29 32 30 31 ...

Страница 22: ...rivers in your system operation to use the USB device Refer to your operating system s manual or documentation for more information 10 VCC Data Data GND Key VCC Data Data GND N C 9 1 2 USB 2 0 USB 6 USB 5 USB 2 0 1 29 32 30 31 29 32 30 31 1 2 8 7 2 22 1 2 1 S1 S3 210 9 2 10 9 Battery 19 USB 13 14 USB 2 USB 1 USB 3 0 USB 4 USB 3 USB 9 10 or optional vertical USB USB 7 8 USB 5 6 RJ45 LAN Ports The L...

Страница 23: ...Light Blue optional This jack is used to connect any audio devices such as Hi fi set CD player tape player AM FM radio tuner synthesizer etc Line out Jack Lime This jack is used to connect a headphone or external speakers Mic in Jack Pink This jack is used to connect an external microphone Front Audio The front audio connector allows you to connect to the second line out and mic in jacks that are ...

Страница 24: ...30 31 1 2 8 7 2 22 1 2 1 S1 S3 210 9 2 10 9 Battery 19 SATA 1 SATA 2 SATA 6 KD631 C236 only SATA 5 Serial ATA 3 0 ports with data transfer rate up to 6Gb s Integrated Advanced Host Controller Interface AHCI controller Supports RAID 0 RAID 1 RAID 5 RAID 10 The Serial ATA connectors are used to connect Serial ATA devices Connect one end of the Se rial ATA data cable to a SATA connector and the other...

Страница 25: ...t to the processor s Voltage Regulator Module VRM The power connectors from the power supply unit are designed to fit the 24 pin and 8 pin connectors in only one orientation Make sure to find the proper orientation before plugging the connectors The system board requires a minimum of 300 Watt power supply to operate Your system configuration CPU power amount of memory add in cards peripherals etc ...

Страница 26: ...1 2 8 7 2 22 1 2 1 S1 S3 210 9 2 10 9 Battery 19 Front Panel Connector HD LED RESET PWR LED ATX SW 12 11 2 1 Front Panel 1 29 32 30 31 29 32 30 31 1 2 8 7 2 22 1 2 1 S1 S3 210 9 2 10 9 Battery 19 HD LED Hard Drive LED This LED will light when the hard drive is being accessed RESET Reset Switch This switch allows you to reboot without having to power off the system PWR LED Power Standby LED When th...

Страница 27: ...ss x16 graphics card that comply to the PCI Express specifications into the PCI Express x16 slot To install a graphics card into the x16 slot align the graphics card above the slot then press it down firmly until it is completely seated in the slot The retaining clip of the slot will automatically hold the graphics card in place PCI Express x4 Slot Install PCI Express cards such as network cards o...

Страница 28: ...d with pin 1 of the S PDIF connector 1 5 5V SPDIF out Ground SPDIF in S PDIF 1 29 32 30 31 29 32 30 31 1 2 8 7 2 22 1 2 1 S1 S3 210 9 2 10 9 Battery 19 The lithium ion battery powers the real time clock and CMOS memory It is an auxiliary source of power when the main power is shut off Safety Measures Danger of explosion if battery incorrectly replaced Replace only with the same or equivalent type ...

Страница 29: ...B_Alert 1 29 32 30 31 29 32 30 31 1 2 8 7 2 22 1 2 1 S1 S3 210 9 2 10 9 Battery 19 LAN LED Connector LAN LED 7 8 1 2 The LAN LED connector is used to detect the connection state of RJ45 LAN ports when the connection is made to an active network via a cable The pin functions of the LAN LED con nector are listed below Pin Pin Assignment Pin Pin Assignment 1 LINK_1000_4 2 LINK_100_4 3 LINK_ACTIVITY_4...

Страница 30: ...fication Revision 1 1 The table below indicates the pin functions of the LPC connector Pin Pin Assignment Pin Pin Assignment 1 L_CLK 2 L_AD1 3 L_RST 4 L_AD0 5 L_FRAME 6 3V3 7 L_AD3 8 GND 9 L_AD2 10 11 INT_SERIRQ 12 GND 13 5VSB 14 5V 1 29 32 30 31 29 32 30 31 1 2 8 7 2 22 1 2 1 S1 S3 210 9 2 10 9 Battery 19 Note The system board used in the following illustrations may not resemble the actual one Th...

Страница 31: ...fter you power up the system the BIOS message appears on the screen and the memory count begins After the memory test the message Press DEL to run setup will appear on the screen If the message disappears before you respond restart the system or press the Reset button You may also restart the system by pressing the Ctrl Alt and Del keys simultaneously Legends Scroll Bar When a scroll bar appears t...

Страница 32: ...tary time clock For example 1 p m is 13 00 00 Hour displays hours from 00 to 23 Minute displays minutes from 00 to 59 Second displays seconds from 00 to 59 System Date The date format is month date year Month displays the month from 01 to 12 Date displays the date from 01 to 31 Year displays the year from 2000 to 2099 Insyde BIOS Setup Utility This is the help for the hour minute second field Vali...

Страница 33: ...a power failure G3 state Always On The system working state Always Off Off except for trickle current to devices such as the power button Wake On RTC Automatically power the system on at a particular time every day from the Real time clock battery Wake up time When Wake On RTC is set to enabled specify the wake up time of the day hour 00 23 minute 00 59 second 00 59 Note Under Dual Boot Type or UE...

Страница 34: ...em Enter Select SubMenu F10 Save and Exit InsydeH2O Setup Utility Rev 5 0 Video Configuration This section configures the video settings Primary Display Set the initial priority Internal Graphics Device Keep IGFX enabled or disabled based on the setup options Boot display Set the display device combination Note To control Primary Display Boot display first go to Boot menu and select different Boot...

Страница 35: ...nter Select SubMenu F10 Save and Exit InsydeH2O Setup Utility Enabled Control Detection of the HD Audio device Disabled HDA will be unconditionally disabled Enabled HDA will be unconditionally enabled Auto HDA will be ena bled if present disabled otherwise Rev 5 0 Video Configuration Primary Display Internal Graphics Device Boot display Choose display device combination Advanced F1 Help Select Ite...

Страница 36: ...alled Not Installed Not Installed Not Installed SATA Configuration KD631 C236 This section is designed to select the SATA controller and the type of hard disk drive which are installed in your system unit SATA Controller s This field is used to enable or disable Serial ATA devices SATA Speed This field is used to select SATA speed generation limit Auto Gen1 Gen2 or Gen3 SATA Mode Selection The mod...

Страница 37: ...nder UEFI environment XHCI Hand off Enable or disable to clear XHCI controller ownership change SMI bit by BIOS USB keyboard mouse stor age support under UEFI and DOS environment It will supporting UEFI en vironment only if set to UEFI Only Legacy USB Support XHCI Hand off Advanced F1 Help Select Item F5 F6 Change Values F9 Setup Defaults Esc Exit Select Item Enter Select SubMenu F10 Save and Exit...

Страница 38: ...E 4 and M 2 This field is used to enable or disable the PCI Express Root Port PCIe Speed Select the speed of the PCI Express Root Port Auto Gen1 Gen2 or Gen3 Hot Plug This field is used to enable or disable the PCI Express Hot Plug Control the PCI Express Root Port Intel I210AT Advanced F1 Help Select Item F5 F6 Change Values F9 Setup Defaults Esc Exit Select Item Enter Select SubMenu F10 Save and...

Страница 39: ...tel Active Management Technology Intel AMT BIOS extension Please refer to Chapter 6 for more information When disabled AMT BIOS Features are no longer supported and user is no longer able to access MEBx Setup Note This option does not dis able Manageability Fea tures in FW Active Management Technology Support Intel AMT Support Enabled Un Configure ME Disabled Advanced F1 Help Select Item F5 F6 Cha...

Страница 40: ...If set to on relevant EFI debug information will show up Enable it to output debug message from COM port Dynamic EFI DEBUG EFI debug print level EFI debug serial port EFI debug baud rate Advanced F1 Help Select Item F5 F6 Change Values F9 Setup Defaults Esc Exit Select Item Enter Select SubMenu F10 Save and Exit InsydeH2O Setup Utility Rev 5 0 On 0x80000000 0x3F8 115200 UEFI Device Manager The sec...

Страница 41: ...S Smart Fan 2 Control Boundary 1 Boundary 2 Boundary 3 Boundary 4 Fan Speed Count 1 Fan Speed Count 2 Fan Speed Count 3 Fan Speed Count 4 COM Port 1 Base I O Address Interrupt RS485 Auto Flow COM Port 2 Base I O Address Interrupt Enable 30 40 50 60 30 40 50 75 Enable 30 40 50 60 30 40 50 75 Enable 30 40 50 60 30 40 50 75 Enable 3F8 IRQ4 Disable Enable 2F8 IRQ3 Note SYS Smart Fan Control CPU Smart ...

Страница 42: ... you select to enable WDT Input any value between 1 to 255 seconds Case Open Enable or disable the case open detection function Advanced F1 Help Select Item F5 F6 Change Values F9 Setup Defaults Esc Exit Select Item Enter Select SubMenu F10 Save and Exit InsydeH2O Setup Utility Fan Speed Count 3 Fan Speed Count 4 SYS Smart Fan 2 Control Boundary 1 Boundary 2 Boundary 3 Boundary 4 Fan Speed Count 1...

Страница 43: ...al Redirect Terminal Type Baud Rate Data Bits Parity Stop Bits Flow Control COMA Enable VT 100 115200 N81 COMB Disable VT 100 115200 N81 COMC Disable VT 100 115200 N81 COMD Disable VT 100 115200 N81 COME Disable VT 100 115200 N81 COMF Disable VT 100 115200 N81 Pci Serial Port 0 22 3 Enable VT 100 115200 N81 Advanced F1 Help Select Item F5 F6 Change Values F9 Setup Defaults Esc Exit Select Item Ent...

Страница 44: ...able to use global setting When enabled the global set ting setting of the COM port will be the same as those in Console Redirection section When disabled the global setting setting of the COM port can be configured indepen dently in this section PortEnable UseGlobalSetting Terminal Type Baud Rate Data Bits Parity Stop Bits Flow Control Advanced F1 Help Select Item F5 F6 Change Values F9 Setup Def...

Страница 45: ...on to change TPM2 state Clear TPM Remove all TPM context associated with a specific owner Set Supervisor Password Set the supervisor s password and the length of the password must be greater than one character When Hidden don t ex poses TPM to 0 Current TPM Device TPM State TPM Availability TPM Operation Clear TPM Supervisor Password Set Supervisor Password Main Advanced F1 Help Select Item F5 F6 ...

Страница 46: ...d then press Enter to exit the system setup without saving your changes Save Setting to file Select this option to save BIOS configuration settings to a USB flash device Restore Setting from file This field will appear only when a USB flash device is detected Select this field to restore setting from the USB flash device Exit system setup and save your changes Exit Saving Changes Load Optimal Defa...

Страница 47: ...ogrammer has been burned and follow the technical person s instructions to confirm that the MAC address should be burned or not Notice BIOS SPI ROM 1 The Intel Management Engine has already been integrated into this system board Due to the safety concerns the BIOS SPI ROM chip cannot be removed from this system board and used on another system board of the same model 2 The BIOS SPI ROM on this sys...

Страница 48: ...dows INF files so that the Intel chipset can be recognized and configured properly in the system To install the utility download KD631 Chipset Driver zip file at our website 1 Setup is ready to install the utility Click Next 2 Read the license agreement then click Accept 3 Go through the readme document for more installa tion tips then click Install 5 After completing installa tion click Restart N...

Страница 49: ...iver and the system rebooted the screen will turn blank for 1 to 2 minutes while WinSAT is running before the Win dows 7 8 1 10 desktop appears The blank screen period is the time Windows is testing the graphics performance We recommend that you skip this process by disabling this function then click Next 4 Setup is now installing the driver Click Next to continue 3 Go through the readme document ...

Страница 50: ...ish Restarting the system will allow the new software installation to take effect 1 Setup is ready to install the driver Click Next Intel LAN Drivers To install the driver download KD631 LAN Driver zip file at our website 1 Setup is ready to install the driver Click Next 2 Click I accept the terms in the license agreement then click Next 3 Select the program features you want installed then click ...

Страница 51: ... to begin the installation 6 After completing installa tion click Finish Kernel Mode Driver Framework For Windows 7 only To install the driver download KD631 KMDF zip file at our website 1 Click Yes to install the update 2 The update is installed now 3 Click Restart Now to restart your computer when the installation is complete ...

Страница 52: ...t our website 1 Setup is ready to install the driver Click Next 2 Read the license agreement then tick I accept the terms in the License Agree ment Click Next 3 Click Next to install to the default folder or click Change to choose another destination folder 4 Please wait while the prod uct is being installed 5 After completing installa tion click Finish ...

Страница 53: ...ead the license agreement then tick I accept the terms in the license agreement Click Next 1 Setup is ready to install the driver Click Next 3 Click Next 4 Setup is currently installing the driver After installation has com pleted click Next 5 Click Yes I want to restart this computer now then click Finish Restarting the system will allow the new software installation to take effect ...

Страница 54: ...are fully Tick I accept the terms in the Li cense Agreement then click Next Intel Rapid Storage Technology The Intel Rapid Storage Technology is a utility that allows you to monitor the current status of the SATA drives It enables enhanced performance and power management for the storage subsystem To install the driver download KD631 IRST Driver zip file at our website Please refer to Chapter 5 fo...

Страница 55: ...ver Click Next 5 Setup is now installing the driver 3 Go through the readme docu ment for system requirements and installation tips then click Next 6 Click Yes I want to restart this computer now then click Finish Restarting the system will allow the new software installation to take effect ...

Страница 56: ...e at our website 1 Setup is now extracting files Note Before installing Microsoft Framework 4 5 make sure you have updated your Windows 7 operating system to Service Pack 3 2 Read the license agreement care fully Click I have read and accept the terms of the License Agree ment then click Install 4 Click Finish 3 Setup is now installing the driver ...

Страница 57: ...2 Utility zip file at our website 1 The setup program is preparing to install the driver 2 The setup program is now ready to install the utility Click Next 3 Click I accept the terms in the license agreement and then click Next 4 Enter the necessary information and then click Next 5 Select a setup type and then click Next 6 Click Install ...

Страница 58: ...re Chapter 4 7 TPM requires installing the Micro soft Visual C package prior to installing the utility Click Install 8 The setup program is currently installing the Microsoft Visual C package 9 Click Finish 10 Click Yes to restart your system ...

Страница 59: ...ftware Chapter 4 Infineon TPM 2 0 Driver and Tool Optional To install the driver download KD631 TPM2 0 Hotfix zip file at our website 1 Click OK 2 Click Yes 3 Setup is now installing the up dates 4 Click Restart now to restart your system ...

Страница 60: ...To install the reader download KD631 C236 Q170 Driver Package iso file at our website 1 Click Next to install or click Change Destination Folder to select another folder 2 Click Install to begin instal lation 3 Setup is now installing the driver 4 Click Finish to exit installation ...

Страница 61: ...o new identical hard disk drives to read and write data in parallel interleaved stacks Data is divided into stripes and each stripe is written alternately between two disk drives This improves the I O performance of the drives at different channel however it is not fault tolerant A failed disk will result in data loss in the disk array RAID 1 Mirroring Disk Array with Fault Tolerance RAID 1 copies...

Страница 62: ...volumes To set the boot type enter the Insyde BIOS and go to Boot Boot Type 1 Go to the Advanced menu of the Insyde BIOS and select UEFI Device Manager UEFI Device Manager Set ting ACPI Configuration CPU Configuration Video Configuration Audio Configuration SATA Configuration USB Configuration PCI Express Configuration ME Configuration Active Management Technology Support MEBX Configuration Debug ...

Страница 63: ...u to monitor the current status of the RAID volume and or SATA drives It enables enhanced performance and power management for the storage subsystem 1 Download KD631 IRST Driver zip file at our website 3 Read the license agree ment and click I accept the terms in the License Agreement Then click Next 2 Setup is ready to install the utility Click Next 4 Go through the readme document to view system...

Страница 64: ...www dfi com 64 Chapter 5 RAID Chapter 5 7 Click Yes I want to restart this computer now to complete the installation and then click Finish ...

Страница 65: ...when critical software agents are removed Enable Intel AMT in the Insyde BIOS 1 Power on the system then press Del to enter the main menu of the Insyde BIOS 2 In the Advanced menu select Active Management Technology Support 3 Select Enabled in the Intel AMT Support field Rev 5 0 When disabled AMT BIOS Features are no longer supported and user is no longer able to access MEBx Setup Note This option...

Страница 66: ...ity Security Boot Rev 5 0 Exit MEBX Configuration Set ting ACPI Configuration CPU Configuration Video Configuration Audio Configuration SATA Configuration USB Configuration PCI Express Configuration ME Configuration Active Management Technology Support MEBX Configuration Debug Configuration UEFI Device Manager SIO NUVOTON6106D Console Redirection Main Advanced F1 Help Select Item F5 F6 Change Valu...

Страница 67: ...sion v11 0 0 0010 Intel R ME v11 8 50 3399 Copyright C 2003 16 Intel Corporation All Rights Reserved MAIN MENU MEBx Login Intel R ME General Settings Intel R AMT Configuration MEBx Exit Intel R ME Password Move Highlight Enter Select Entry Esc Exit Verify password 7 Select Intel R ME General Settings then press Enter Intel R Management Engine BIOS Extension v11 0 0 0010 Intel R ME v11 8 50 3399 Co...

Страница 68: ... provided under Intel R ME Password then press Enter Intel R Management Engine BIOS Extension v11 0 0 0010 Intel R ME v11 8 50 3399 Copyright C 2003 16 Intel Corporation All Rights Reserved INTEL R ME PLATFORM CONFIGURATION Change ME Password Local FW Update Enabled Intel R ME New Password Move Highlight Enter Select Entry Esc Exit Intel R ME Password Change ME Password Local FW Update Enabled Int...

Страница 69: ... Control Disabled Enabled INTEL R AMT CONFIGURATION Move Highlight Enter Complete Entry Esc Discard Changes 14 In the Intel R AMT Configuration menu select SOL Storage Redirection KVM then press Enter Intel R Management Engine BIOS Extension v11 0 0 0010 Intel R ME v11 8 50 3399 Copyright C 2003 16 Intel Corporation All Rights Reserved Manageability Feature Selection Enabled SOL Storage Redirectio...

Страница 70: ...abled Move Highlight Enter Complete Entry Esc Discard Changes 18 Select KVM Feature Selection then press Enter Select Enabled or Disabled then press Enter Intel R Management Engine BIOS Extension v11 0 0 0010 Intel R ME v11 8 50 3399 Copyright C 2003 16 Intel Corporation All Rights Reserved SOL Storage Redirection KVM Username and password Enabled SOL Enabled Storage Redirection Enabled KVM Featur...

Страница 71: ...oose to use a password only during setup and configuration or to use a pass word anytime the system is being accessed Intel R Management Engine BIOS Extension v11 0 0 0010 Intel R ME v11 8 50 3399 Copyright C 2003 16 Intel Corporation All Rights Reserved Manageability Feature Selection Enabled SOL Storage Redirection KVM User Consent Password Policy Anytime Network Setup Activate Network Access Un...

Страница 72: ...ME SETTINGS Host Name Domain Name Shared Dedicated FQDN Dynamic DNS Update 26 Select Domain Name then press Enter Enter the computer s domain name then press Enter Intel R Management Engine BIOS Extension v11 0 0 0010 Intel R ME v11 8 50 3399 Copyright C 2003 16 Intel Corporation All Rights Reserved INTEL R ME NETWORK NAME SETTINGS Host Name Domain Name Shared Dedicated FQDN Dynamic DNS Update Ent...

Страница 73: ...9 Copyright C 2003 16 Intel Corporation All Rights Reserved Move Highlight Enter Select Entry Esc Exit TCP IP SETTINGS Wired LAN IPV4 Configuration 29 Select Periodic Update Interval then press Enter Enter value then press Enter Intel R Management Engine BIOS Extension v11 0 0 0010 Intel R ME v11 8 50 3399 Copyright C 2003 16 Intel Corporation All Rights Reserved INTEL R ME NETWORK NAME SETTINGS H...

Страница 74: ... 0 Preferred DNS Address 0 0 0 0 Alternate DNS Address 0 0 0 0 Enter Complete Entry Esc Discard Changes 34 Select Subnet Mask Address then press Enter Enter address then press Enter Intel R Management Engine BIOS Extension v11 0 0 0010 Intel R ME v11 8 50 3399 Copyright C 2003 16 Intel Corporation All Rights Reserved WIRED LAN IPV4 CONFIGURATION DHCP Mode Disabled IPV4 Address 0 0 0 0 Subnet Mask ...

Страница 75: ...C 2003 16 Intel Corporation All Rights Reserved WIRED LAN IPV4 CONFIGURATION DHCP Mode Disabled IPV4 Address 0 0 0 0 Subnet Mask Address 0 0 0 0 Default Gateway Address 0 0 0 0 Preferred DNS Address 0 0 0 0 Alternate DNS Address 0 0 0 0 Enter Complete Entry Esc Discard Changes 37 Select Alternate DNS Address then press Enter Enter address then press Enter Intel R Management Engine BIOS Extension v...

Страница 76: ...ent Provisioning Mode Provisioning Record Provisioning Server IPV4 IPV6 _ Provisioning Server FQDN _ RCFG TLS PKI Provisioning Mode PKI 42 In the Intel R Remote Setup And Configuration menu select Provisioning Re cord then press Enter Intel R Management Engine BIOS Extension v11 0 0 0010Intel R ME v11 8 50 3399 Copyright C 2003 16 Intel Corporation All Rights Reserved INTEL R REMOTE SETUP AND CONF...

Страница 77: ...d INTEL R REMOTE CONFIGURATION Start Configuration Move Highlight Enter Select Entry Esc Exit This will activate Remote Configuration Continue Y N 46 Press Esc until you return to the Intel R Remote Setup And Configuration menu Select TLS PKI then press Enter Select Remote Configuration then press Enter Select Enabled or Disabled then press Enter Enter FQDN of provisioning server Intel R Managemen...

Страница 78: ...256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 Hash Name Active Default Algorithm VeriSign Class 3 VeriSign Class 3 Go Daddy Class 2 Comodo AAA CA Starfield Class 2 VeriSign Class 3 VeriSign Class 3 VeriSign Class 3 GTE CyberTrust G1 Baltimore Cyber Tr Cyber Trust Global Verizon Global Ro Entrust net CA 2 Entrust Root CA V...

Страница 79: ...the monitor s power switch is on 2 Check that one end of the monitor s power cord is properly attached to the monitor and the other end is plugged into a working AC outlet If necessary try another outlet 3 Check that the video input cable is properly attached to the monitor and the system s display adapter 4 Adjust the brightness of the display by turning the monitor s brightness control knob The ...

Страница 80: ...rks by attaching it to a serial port that is working and configured correctly If the serial device does not work either the cable or the serial device has a problem If the serial device works the problem may be due to the onboard I O or the address setting 4 Make sure the COM settings and I O address are configured correctly Keyboard Nothing happens when a key on the keyboard was pressed 1 Make su...