23
Clearance Requirements
Your CPU comes with a heat sink mounted on top. To maintain proper
airflow once the upgrade is installed on the system board, the CPU and
heat sink require certain space clearances.
The clearance above the CPUs fan/heat sink must be at least 0.4
inches. The clearance on at least 3 of 4 sides of the CPU must be at
least 0.2 inches. The cables (for floppy drive, hard drive, CD-ROM, etc.)
must be routed clear of the CPU and its airspace.
Fan Exhaust
The CPU must be kept cool by using a fan with heat sink. The tempera-
ture of the air entering the fan/heat sink cannot exceed 45°C (113°F).
The ambient or room temperature must be below 37°C (99°F).
In order to provide proper airflow to the CPU and fan/heat sink, all mov-
able obstructions (power supply cables, cards, floppy disk cables) must
be clear of the CPU fan/heat sink component in accordance with the
space clearance discussed in the Clearance Requirements section of
this manual.