background image

44

User's Manual | 

CS350

Chapter 3

BIOS SETTINGS

 

X

Chipset

 

X

Chipset

Primary Display

Select which of IGFX/PEG/PCI Graphics device to be the primary display.

Internal Graphics

Keep IGFX enabled based on the setup options.

Graphics Configuration

To configure relevant graphics settings.

Содержание CS350-C246

Страница 1: ...CS350 C246 Q370 A 572 M 2032 MicroATX Industrial Motherboard User s Manual...

Страница 2: ...CC and DOC Statement on Class B This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC rules These limits are designed to provid...

Страница 3: ...y 28 SMBus 28 LAN LED 29 Expansion Slots 29 Installing the M 2 Module 30 LPC 31 Chapter 3 BIOS Settings 32 Overview 32 Main 33 Advanced 33 RC ACPI Configuration 34 CPU Configuration 34 Power Performan...

Страница 4: ...lling them in your system unit Static electrical discharge can damage computer components without causing any signs of physical damage You must take extra care in handling them to ensure against elect...

Страница 5: ...your dealer or sales representative Optional Items USB 2 0 USB 3 1 cable COM cable SATA cable Thermal Solution Heat sink and fan DP to HDMI dongle The board and accessories in the package may not com...

Страница 6: ...AVC H 264 MPEG2 VC1 WMV9 JPEG MJPEG HEVC H265 VP8 VP9 HW Encode MPEG2 AVC H264 JPEG HEVC H265 VP8 VP9 Display 1 x DP resolution up to 4096x2106 60Hz 1 x HDMI 1 4b resolution up to 4096x2106 24Hz 1 x...

Страница 7: ...MI 1 4b resolution up to 4096x2106 24Hz 1 x DVI I DVI D signal resolution up to 1920x1200 60Hz Triple Displays DVI D DP HDMI EXPANSION Interface 2 x PCIe x16 Gen 3 1 x16 signals or 2 x8 signals 2 x PC...

Страница 8: ...scale speeds by forming multiple lanes The x4 PCI Express lane supports transfer rate of 4 Gigabyte per second 2 directions The PCI Express architecture also supports high performance graphics infrast...

Страница 9: ...al I O DIO 1 Front Audio 1 2 10 9 JP3 6 5 2 1 6 5 2 1 JP2 12V Power 1 5 JP1 JP4 1 2 5 6 1 2 5 6 JP6 JP8 1 2 5 6 1 2 5 6 1 Chassis Intrusion 1 DP COM1 HDMI DVI D 11 1 10 20 USB 3 1 Gen 2 USB 5 6 Note S...

Страница 10: ...the same channel DIMMs in a channel can be identical or completely different However we highly recommend using identical DIMMs Not all slots need to be populated Dual Channel DIMMs of the same memory...

Страница 11: ...e edges of the card and lock the card in place Socket Side View Socket Top View Memory Module Notch Key Eject Tab Eject Tab Step 3 Step 2 Step 1 Step 1 Step 2 Step 3 X System Memory X Installing the D...

Страница 12: ...s released Retention tab Load lever Important 1 Before you proceed make sure 1 the LGA 1151 socket comes with a protective cap 2 the cap is not damaged and 3 the socket s contact pins are not bent If...

Страница 13: ...f the CPU socket shown in the photo Golden triangular mark X CPU X Installing the CPU 7 2 Two keys on the socket and notches on the CPU also facilitate alignment 7 3 The CPU s notch will fit into the...

Страница 14: ...nk on top of the CPU the compound will disperse evenly Some heat sinks come with a patch of pre applied thermal paste Do not apply thermal paste if the fan heat sink already has a patch of thermal pas...

Страница 15: ...ured to the same serial mode 2 3 On Clear CMOS COM 1 1 2 On Normal default 1 3 4 6 On 1 3 2 4 On 3 5 4 6 On 3 5 4 6 On 3 5 2 4 On 3 5 4 6 On COM 1 Serial Mode 6 4 2 5 3 1 6 4 2 5 3 1 6 4 2 5 3 1 6 4 2...

Страница 16: ...plex or RS485 The three jumpers must all be configured to the same serial mode COM 2 1 3 4 6 On 1 3 2 4 On 3 5 4 6 On 3 5 4 6 On 3 5 2 4 On 3 5 4 6 On COM 2 Serial Mode 6 4 2 5 3 1 6 4 2 5 3 1 6 4 2 5...

Страница 17: ...PCIe x16 PCIE2 PCIe x16 PCIE3 PCIe x4 PCIE4 PCIe x4 Line Out Line In Note Buzzer Battery Intel C246 Q370 1 2 10 1 2 10 USB 7 8 USB 2 0 S PDIF USB 14 USB 2 0 JP5 USB 9 10 USB 2 0 Note 1 2 19 M 2 E Key...

Страница 18: ...ports consist of the following 1 PS 2 Keyboard Mouse port 2 USB 2 0 ports 1 Serial COM port 1 DVI I port DVI D Signal 1 DP port 1 HDMI port 2 RJ45 LAN ports 2 USB 3 1 Gen1 ports 2 USB 3 1 Gen2 ports 1...

Страница 19: ...USB 5 USB 2 0 DVI I DVI D Signal HDMI DP X Rear I O Ports Graphics Display DisplayPort The DisplayPort DP is a digital display interface used to connect a display device such as a computer monitor It...

Страница 20: ...PHY with iAMT12 0 only Xeon Core i7 i5 supports iAMT LAN2 Intel I211AT PCIe Gigabit Ethernet LAN Controller X Rear I O Ports LAN 1 LAN 2 The system board is equipped with three rear audio jacks Line i...

Страница 21: ...RS485 as well as RS232 with without power Jumper Setting Serial mode and RS232 with without power of COM 1 are configured via jumper settings as previously instructed in this chapter Pin Standard RS2...

Страница 22: ...mode and RS232 with without power of COM 2 are configured via jumper settings as previously instructed in this chapter Pin Standard RS232 RS232 with Power COM 2 RS422 COM 2 RS485 COM 2 1 DCD 12V TXD...

Страница 23: ...he S state s USB Ports X Internal I O Connectors VCC Data Data GND Key VCC Data Data GND N C 2 10 1 USB USB 2 0 Pin Assignment USB 3 1 Pin Assignment USB 9 10 left 11 12 middle 14 right USB 2 0 USB 5...

Страница 24: ...h provides data rate up to 6Gb s Connect one end of the Serial ATA cable to a SATA connector and the other end to your Serial ATA device 7 RX GND TX TX GND 1 RX GND SATA Serial ATA X Internal I O Conn...

Страница 25: ...1 19 2 20 1 Pin Assignment 1 Ground 2 Power 3 Sense System Fan 1 2 3 CPU Fan PWM 3 pin Fan Pin Assignment 4 pin Fan Pin Assignment Pin Assignment 1 Ground 2 Power 3 Sense 4 Speed Control Cooling Fan...

Страница 26: ...12V 3 3V 3 3V 12V GND PS_ON GND GND GND NC 5V 5V 5V GND 1 13 12 24 GND 12V The board supports the chassis intrusion detection function Connect the chassis intrusion sensor cable from the chassis to t...

Страница 27: ...will blink at 4 second intervals ATX SW ATX Power Switch This switch is used to power on or off the system The Sony Philips Digital Interface S PDIF connector is for audio output to external audio eq...

Страница 28: ...lder Safety Measures There exists explosion hazard if the battery is incorrectly installed Replace only with the same or equivalent type recommended by the manufacturer Dispose of used batteries accor...

Страница 29: ...Assignment Pin Assignment 1 LAN1 GBE_1000 2 LAN1 GBE_100 3 LAN1 GBE_LED_LINK_ACT 4 3V3DU 5 LAN2 LINK_1000 6 LAN2 LINK_100 7 LAN2 LINK_ACTIVITY 8 3V3DU LAN LED Connector Expansion Slots M 2 Sockets Th...

Страница 30: ...notch on card is aligned to the key on the socket 5 Make sure the standoff screw is removed from the standoff M 2 Module M 2 Socket Key Stand off Notch Please follow the steps below to install the ca...

Страница 31: ...0 X Internal I O Connectors LPC The LPC connector is used for debugging LPC Connector LPC Pin Assignment Pin Assignment Pin Assignment 1 L_CLK 2 L_LAD1 3 L_RST 4 L_LAD0 5 L_FRAME 6 3 3V 7 L_LAD3 8 GND...

Страница 32: ...r is off In general the information stored in the CMOS RAM of the EEPROM will stay unchanged unless a configuration change has been made such as a hard drive replaced or a device added It is possible...

Страница 33: ...based on the 24 hour military time clock For example 1 p m is 13 00 00 Hour displays hours from 00 to 23 Minute displays minutes from 00 to 59 Second displays seconds from 00 to 59 X Advanced The Adva...

Страница 34: ...ation Intel VMX Virtualization Technology When this field is set to Enabled the VMM can utilize the additional hardware capabilities provided by Vanderpool Technology Active Processor Cores Select num...

Страница 35: ...ng is executing PCH FW Configuration ME State When this field is set to Disabled ME will be put into ME Temporarily Disabled Mode Manageability Features State Enable or disable Intel R Manageability f...

Страница 36: ...X PCH FW Configuration AMT Configuration AMT Configuration Secure Erase Configuration USB Provisioning of AMT Enable or disable AMT USB Provisioning Secure Erase Mode Select Secure Erase module behav...

Страница 37: ...le to hide unconfigure ME confirmation prompt when attempting ME unconfiguration Unconfigure ME Enable or disable to unconfigure ME with resetting password to default Firmware Update Configuration Me...

Страница 38: ...y device such as an TPM 2 0 to achieve hardware level security via cryptographic keys X Advanced NCT6116D Super IO Configuration WatchDog Timer Unit Select WatchDog Timer Unit Second or Minute SuperIO...

Страница 39: ...COM port RS485 Auto Flow Enable or disable RS485 auto flow This field is only available for COM ports that support RS485 mode X Advanced X NCT6116D Super IO Configuration NCT6116D HW Monitor This sec...

Страница 40: ...1 setting the fan speed will be turned up to the designated speed of the Fan Speed Count 1 field Fan Speed Count 1 to Fan Speed Count 4 Set the fan speed the value ranging from 1 100 100 being full sp...

Страница 41: ...Select parity bits None Even Odd Mark or Space Stop Bits Select stop bits 1 bit or 2 bits Flow Control Select flow control type None or Hardware RTS CTS X Advanced X Serial Port Console Redirection U...

Страница 42: ...a detect count Set the number of times the presence of media will be checked Use either or numeric keys to set the value Network Stack Configuration X Advanced CSM Support This section is used to enab...

Страница 43: ...ameters USB Power Control X Advanced This page provides options of the USB power type 5V_Dual USB keyboard and mouse can wake up the system from S3 S4 mode 5V USB keyboard and mouse can t wake up the...

Страница 44: ...TTINGS X Chipset X Chipset Primary Display Select which of IGFX PEG PCI Graphics device to be the primary display Internal Graphics Keep IGFX enabled based on the setup options Graphics Configuration...

Страница 45: ...19 Enable or disable onboard NIC Wake on LAN Enable Enable or disable integrated LAN to wake the system Above 4GB MMIO BIOS assignment Enable or disable MemoryMappedIO BIOS assignment above 4GB This o...

Страница 46: ...tion SATA And RST Configuration X Advanced SATA Controller s This field is used to enable or disable the Serial ATA controller SATA Speed This field is used to select SATA speed generation limit Auto...

Страница 47: ...Chapter 3 BIOS SETTINGS X Chipset X PCH IO Configuration HD Audio Control the detection of the HD Audio device Disabled HDA will be unconditionally disabled Enabled HDA will be unconditionally enabled...

Страница 48: ...ecure Boot is Enabled Platform Key PK is enrolled System Mode is User and CSM is disabled After enabling disabling Secure Boot please save the configuration and restart the system When configured and...

Страница 49: ...e Allow the image to run in Secure Boot mode Enroll SHA256 Hash certificate of a PE image into Authorized Signature Database db Press Enter and select a storage device listed in the pop up menu select...

Страница 50: ...dialog box will appear Select Yes to reset the system after saving all changes made Discard Changes and Reset To discard the changes select this field and then press Enter A dialog box will appear Sel...

Страница 51: ...not be removed from this system board and used on another system board of the same model 2 The BIOS SPI ROM on this system board must be the original equipment from the factory and cannot be used to r...

Страница 52: ...red off significantly reducing desk side visits Repair Remotely repair systems after OS failures Alerting and event logging help detect problems quickly to reduce downtime Protect Intel AMT s System D...

Страница 53: ...ialog box will appear Select Yes and press Enter to reset the system after saving all changes made X Entering Management Engine BIOS Extension MEBX When the system reboots the following message will b...

Страница 54: ...ill show up 1 Enter the default password admin 2 Enter a new password and then press Enter The password must include 8 32 characters Strong 7 bit ASCII characters excluding and characters At least one...

Страница 55: ...assword must include 8 32 characters Strong 7 bit ASCII characters excluding and characters At least one digit character 0 1 9 At least one 7 bit ASCII non alpha numeric character above 0x20 e g At le...

Страница 56: ...to show relevant options Manageability Feature Selection Select Enabled or Disabled then press Enter When disabled all the following fields will be hidden After disabling the field system restart is r...

Страница 57: ...MEBX X Intel R Standard Manageability Configuration X Intel R Standard Manageability Configuration SOL Storage Redirection KVM Move the cursor to select a field and press Enter to display options SOL...

Страница 58: ...ing setup and configuration or to use a password anytime the system is being accessed User Consent Move the cursor to select a field and press Enter to display options User Opt in Select NONE or KVM o...

Страница 59: ...ress Enter Network Setup Move the cursor to select a field and press Enter to display options Host Name Enter the computer s host name and then press Enter Domain Name Enter the computer s domain name...

Страница 60: ...ion and then press Enter X Network Setup X Network Setup X Intel R ME Network Name Settings X MEBX X MEBX X Intel R Standard Manageability Configuration X Intel R Standard Manageability Configuration...

Страница 61: ...Preferred DNS Address Insert a value from 0 0 0 0 to 255 255 255 255 in IPv4 format Alternate DNS Address Insert a value from 0 0 0 0 to 255 255 255 255 in IPv4 format Activate Network Access Select...

Страница 62: ...Provisioning Mode The current mode Public Key Infrastructure PKI is displayed Provisioning Record Press Enter to view the record Provisioning Server IPV4 IPV6 Enter the address of the server then pre...

Страница 63: ...ption and authentication and the TLS protocol for communication security to ensure remote configuration safety Remote Configuration Select Enabled or Disabled then press Enter PKI DNS Suffix Specify t...

Страница 64: ...ion activate or deactivate a hash Esc exit Power Control Under the Intel R Standard Manageability Configuration menu select Power Control then press Enter Intel R AMT ON in Host Sleep States Select an...

Страница 65: ...65 User s Manual CS350 Chapter 4 INTEL AMT SETTINGS MEBx Exit Under the Main Menu select MEBx Exit and then press Enter Press Y to confirm or N to abort X MEBX...

Страница 66: ...iding the benefits of both RAID 0 and RAID 1 Use four new drives or an existing drive and three new drives for this configuration RAID Level Min Drives Protection Description RAID 0 2 None Data stripi...

Страница 67: ...t enables enhanced performance and power management for the storage subsystem Step 3 Create a RAID Volume 1 Go to the Advanced menu of the AMI BIOS and select Intel R Rapid Storage Technology 2 The sc...

Отзывы: