D12002 

Shaft Packing Adjustment 

Removal of the valve from the line for shaft packing adjustment is not required as long as the shaft is 
accessible. 

1.

  If the actuator is powered, disconnect and lock out the pneumatic, hydraulic, or electrical power 

to prevent accidental operation of the actuator. 

 

Accidental operation of power actuator can cause personal injury or equipment 
damage. Disconnect and lock out power to actuator before servicing.

 

2.

  Tighten packing gland screws evenly only until leaking stops, see Figure 4. 

Caution! 

Do not exceed 22 ft lbs of torque on the screws. Overtightening screws can damage 

the shaft packing and cause excessive shaft torque. 

Shaft Packing Replacement 

Removal of the valve from the line for shaft packing replacement is not required as long as the shaft is 
accessible. 

 

Servicing the valve while the pipeline is under pressure can cause personal injury or 
equipment damage. Relieve pipeline pressure before servicing the valve. 

1.

  Relieve the pressure in the pipeline and close the valve. 

2.

  If the actuator is powered, disconnect and lock out the pneumatic, hydraulic, or electrical power 

to prevent accidental operation of the actuator. 

 

Accidental operation of power actuator can cause personal injury or equipment 
damage. Disconnect and lock out power to actuator before servicing. 

3.

  Remove the hex head cap screws from the packing gland studs and move the gland upward. 

Remove the packing with a flexible packing hook or similar tool. Clean the packing area, being 
careful not to damage it. 

4.

  Obtain the new packing. The type of packing used in the Willamette VMC-2200 cone valve is v-

packing. V-packing consists of a male and female adapter ring and several v-rings, see Figure 
4. Make sure it is clean, and has not picked up any dirt in handling before installing it. Lubricate 
I.D. of each packing ring. 

5.

  Cut the rings to fit around the shaft. Joints of successive rings should be staggered at least 90 

degrees apart when being installed. First, install male adapter.  Secondly, install the v-rings one 
at a time with the opening of the “v” facing down. After all v-rings are installed, install the female 
adapter. Each ring should be firmly seated with a tamping tool. Do not depend on the packing 
gland entirely to seat the set of rings properly. This practice will jam the last rings installed but 
leave the first ones loose in the box. 

Содержание WILLAMETTE VMC-2200

Страница 1: ...DeZURIK Inc Sartell Minnesota USA Phone 320 259 2000 www dezurik com info dezurik com WILLAMETTE VMC 2200 CONE VALVES Instruction D12002 February 2015...

Страница 2: ...rom service with suitable protection for any potential pipeline material in the valve Inspection Your Willamette VMC 2200 Cone Valve has been packaged to provide protection during shipment however it...

Страница 3: ...ontents Description 4 Handling and Storage 4 Installation 5 Fusion Powder Coated Valves 5 Maintenance 6 General 6 Lubrication 6 Valve Assembly 18 Larger 6 Torque Unit 6 Shaft Packing Adjustment 7 Shaf...

Страница 4: ...hout shutdown of the pipeline The operator is equipped with an external valve position indicator Bearings are provided on the top and bottom of the plug to fully support the plug away from the body se...

Страница 5: ...the installation and eliminate any distortion to the valve body Ensure the valve and pipeline flanges are concentric to ensure proper flange sealing and seat leakage control Tighten the flange bolts...

Страница 6: ...he valve body and cover is fitted with two lubrication points for the lower and upper body bushings Lubricate at the Upper Bushing Grease Point on the cover and the Lower Bushing Grease Point located...

Страница 7: ...disconnect and lock out the pneumatic hydraulic or electrical power to prevent accidental operation of the actuator Accidental operation of power actuator can cause personal injury or equipment damag...

Страница 8: ...ate or open position 2 After the valve has been moved to either an intermediate or open position power down disconnect and or lockout any electric hydraulic or pneumatic power to prevent accidental op...

Страница 9: ...DeZURIK Willamette VMC 2200 Cone Valves February 2015 Page 9 D12002 Drawings Figure 1 Valve Assembly...

Страница 10: ...DeZURIK Willamette VMC 2200 Cone Valves D12002 Page 10 February 2015 Drawings Continued Figure 2 Torque Unit Assembly Detail...

Страница 11: ...DeZURIK Willamette VMC 2200 Cone Valves February 2015 Page 11 D12002 Drawings Continued Figure 3 T8 9 Torque Unit Assembly Detail Figure 4 Packing Detail...

Страница 12: ...g Blown flange gasket Replace flange gasket Miss alignment or damage to field piping and supports Adjust miss alignment or repair piping or supports Damaged flange face s or improper flange connection...

Страница 13: ...l be the only effective guarantee or warranty binding on Seller despite anything to the contrary contained in the purchase order or represented by any agent or employee of Seller in writing or otherwi...

Отзывы: