Description  

APCO CSV-1600 Surge Check Valve is designed for installation to the inlet of the existing Air/Vacuum 
Valve on the line. It consists of a body, seat, flow-disc and compression spring. The surge check unit will 
operate on the inter-phase between the kinetic energy and relative velocity flows of air and water. After 
air passes through and water rushes into the surge check, the disc starts to close, reducing the rate of 
flow of water into the air valve by means of throttling orifices in the disc to prevent water hammer in the 
air valves. The surge check orifices are adjustable for regulation in the field to suit operating conditions. 

Handling and Storage  

Lifting the valve improperly may damage it. Do not fasten lifting devices through the seat opening in the 
body. Lift the valve with

 

slings, chains or cables fastened around the valve body, or fastened to bolts or

 

rods through bolt holes in the flanges. 

If installation will be delayed, place valve indoors in secure, weather tight storage. If temporary outside 
storage is unavoidable, make sure a vermin proof rain cover (water shedding tarp, etc.) is secured 
around/over the valve to keep off rain and mud.  Skid and set the assembly on a flat, solid, and well 
drained surface for protection from ground moisture, runoff and pooled rain water. 

Installation 

The Surge Check Valve should always be installed in a vertical position.  An isolation valve between this 
unit and the transmission (pipeline) system is recommended.   

  Before installation, remove foreign material such as weld spatter, oil, grease, and dirt from the 

pipeline. 

  Prepare pipe ends and install valves in accordance with the pipe manufacture’s instructions for 

the joint used. 

 

Do not deflect the pipe-valve joint. Minimize bending stresses in the valve end 
connection with pipe loading.  

  Tighten the flange bolts or studs in a crisscross pattern and minimum of four stages. 

Fusion/Powder Coated Valves  

 

 

Valves with fusion/powder coated exterior paint require flat washers to be 
installed under the flange nuts when installing the valve to the pipeline flange to 
prevent the paint from cracking or chipping.

 

 

Содержание APCO CSV-1600

Страница 1: ...DeZURIK Inc Sartell Minnesota USA Phone 320 259 2000 www dezurik com info dezurik com APCO CSV 1600 SURGE CHECK VALVE Instruction D12022 January 2013 ...

Страница 2: ...ion during shipment however items can be damaged in transport Carefully inspect the unit for damage upon arrival and file a claim with the carrier if damage is apparent Parts Replaceable wear parts are listed on the assembly drawing These parts can be stocked to minimize downtime Order parts from your local DeZURIK sales representative or directly from DeZURIK When ordering parts please provide th...

Страница 3: ...rge Check Valves January 2013 Page 3 D12022 Table of Contents Description 4 Handling and Storage 4 Installation 4 Fusion Powder Coated Valves 4 Maintenance 5 Disassembly Procedure 5 Assembly Procedure 5 Operation 6 Drawings 6 ...

Страница 4: ...stallation will be delayed place valve indoors in secure weather tight storage If temporary outside storage is unavoidable make sure a vermin proof rain cover water shedding tarp etc is secured around over the valve to keep off rain and mud Skid and set the assembly on a flat solid and well drained surface for protection from ground moisture runoff and pooled rain water Installation The Surge Chec...

Страница 5: ...es it may be necessary to use penetrating oil or rust solvent to loosen the rust that may have formed between the body and seat Also it may be helpful to turn the seat against the body to allow the seat retaining ball 6 to fall out of the groove Check if center guide boss is worn out 5 Lift plug 3 and spring 4 Check for bent or worn out stem 6 Remove retaining ring 5B and bushing 5A 7 Clean all su...

Страница 6: ...e closing of the Air Vacuum Valve regardless of the initial velocity flows involved and minimizes pressure surges when the valve closes As soon as the Air Vacuum Valve is closed the pressure on both sides of the Surge Check Valve disc equalizes and the disc automatically returns to its open position This means the Air Vacuum Valve does not need an incipient vacuum to open but can open at any time ...

Страница 7: ...ll be the only effective guarantee or warranty binding on Seller despite anything to the contrary contained in the purchase order or represented by any agent or employee of Seller in writing or otherwise notwithstanding including but not limited to implied warranties THE FOREGOING REPAIR AND REPLACEMENT LIMITED WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES OBLIGATIONS AND LIABILITIES INCLUDING ALL W...

Отзывы: