DeZurik AFR3 Скачать руководство пользователя страница 5

DeZURIK

  

AFR3 Filter Regulator used on Pneumatic Cylinder Actuators  

August 2013   

 

 

 

     Page 5 

 

 

 

 

        D11033 

Maintenance

 

continued

 

4.  Liquid level in the bowl must be kept below the level indicator line as marked. It is recommended 

practice to drain a unit equipped with the manual drain at least once during an eight (8) hour pe-
riod. To do so, rotate the drain knob to the left one or two turns.* 

5.  Before returning unit to service, insure that all seals have been properly reinstalled  or  replaced  and 

components requiring torque have been properly tightened. Also, insure that bowl seal O-ring 
and bowl have been installed properly and that the bowl is in the locked position and the drain is 
properly secured. 

Note: In the event the drain knob is over-rotated, it may become disengaged from the drain stem.  In 
such a case, pull down on both the knob and the stem while rotating clockwise to re-engage. (view 
from below) 

1. KNOB 
2. PANEL 

NUT 

3. BONNET 
4. BODY 

COVER 

5. THRUST 

WASHER 

6.  ADJUSTING SCREW ASSEMBLY 
7. MAIN 

SPRING 

8. SLIP 

RING 

9. DIAPHRAGM 

ASSEMBLY 

10. BODY ASSEMBLY 
11. VALVE ASSEMBLY 
12. VALVE SPRING 
13. “OLD” DESIGN 
14. “NEW” DESIGN 
15. DEFLECTOR 
16.  5 MICRON ELEMENT 
17. RETAINER 
18.  AUTOMATIC FLOAT DRAIN 
19.  AUTO DRAIN O-RING 
20. BOWL O-RING 
21.  NETAL BOWL W/SIGHT GAUGE 
22. AUTOMATIC DRAIN NUT 
23. DRAIN STEM 
24.  DRAIN STEM O-RING 
25. DRAIN SEAT 
26.  DRAIN SEAT O-RING 
27.  PLASTIC BOWL/BOWL GUARD ASSEMBLY 
28. DRAIN KNOB 