- 37 -
ARC CLR <-
WindTurbine
Pic 8.27
ARC OFF <<
WindTurbine
NAME
DESCRIPTION
Ac�veP
Adjust the output ac�ve power in %
0-110%
OFF/Q(P)/PF(P)
/Q(U)/PF/Q(%)
ON/OFF
ON/OFF
ON/OFF
ON/OFF
ON/OFF
0-100%
0-1000s
-0.8~+0.8
Fun_ISO
Fun_RCD
Self-check
Island
Meter
Limiter
Feed_IN %
Q-Mode
Vref
PF
Mul�ple reac�ve power control modes
Grid reference voltage for func�ons including
Q(U),PF(P),P(U)etc.
Power Fator
Insula�on resistance detec�on
Residual current detec�on
Inverter's self-check �me.The default value 60s
An�-islanding protec�on
Energy meter.If inverter will connect meter,then
set here to ON
If inverter will connect SUN limiter,then set here
to ON
It is used to deploy how much power can be
feed in to grid.(For example, Feed_in=50% of the
36KW model, which means Max. 18KW .power
can be feed into grid. And, this parameter is
valid only a�er connec�ng a meter and the
meter func�on is "ON").
RANGE
0-100%
80-260V
ReactP
Adjust reac�ve power output in %
ARC ON <-
WindTurbine