4. TECHNICAL DATA
4. TECHNICAL DATA
Type designation
900ID2.5AB1
Rated voltage
220V~60Hz
Rated power input
900W
Speed, n
0
0-3000/min
Max. collet diamater
Ø13mm
Drilling capacity
-- in metal
-- in concrete
-- in wood
13mm
16mm
34mm
Level of acoustic pressure L
pA
(K
pA
=3dB(A))
96.1 dB(A)
Level of acoustic power L
wA
(K
wA
=3dB(A))
107.1 dB(A)
Level of vibration a
h
(K=1.5m/s
2
)
Drilling into steel a
h,D
6,706m/s
2
Impact drilling into concrete a
h,ID
13,542m/s
2
NOTE:
the declared vibration total value and the declared noise emission values have been measured in
accordance with a standard test method and may be used for comparing one tool with another;
the declared vibration total value and the declared noise emission values may also be used in a
preliminary assessment of exposure.
WARNING:
the vibration emission and noise emissions during actual use of the power tool can
from
the declared total value depending on the ways in which the tool is used, especially what kind
of work piece is processed;
Identify safety measures to protect the operator that are based on an estimation of exposure
in the actual conditions of use (taking account of all parts of the operating cycle such as the
times when the tool is switched and when it is running idle in addition to the trigger time).
Depending on the actual use of the product the vibration values can
from the declared
total! Adopt proper measures to protect yourself against vibration exposures! Take the whole
work process including times the product is running under no load or switched into
consideration! Proper measures include among others regular maintenance and care of the
product and application tools, keeping hands warm, periodical breaks and proper planning of
work processes!