Manufacturer’s Declaration
The intraoral camera emits electromagnetic energy at levels compliant
to international standards; however, interference between the camera
and other devices is possible if located in close proximity. The customer
or the user of the camera can help prevent electromagnetic interference
by locating sensitive devices away from the camera.
This camera, classified as Medical Electrical Equipment, requires spe-
cial precautions regarding EMC and must be installed and put into ser-
vice according to the EMC information provided in the accompanying
product documentation. Portable and mobile RF communications
equipment can effect Medical Electrical Equipment. This camera com-
plies with EMC requirements when used with the cables and accesso-
ries supplied with the product. The use of accessories and cables other
than those sold by DEXIS, LLC and specified as replacement parts for
internal components, may result in increased emissions or decreased
immunity of this camera. This camera should not be used adjacent to or
stacked with other equipment. If adjacent or stacked use is necessary,
this camera should be observed to verify normal operation in the con-
figuration in which it will be used.
Guidance and manufacturer’s declaration - electromagnetic emissions
for all
EQUIPMENT and SYSTEMS
Guidance and manufacturer’s declaration – electromagnetic emissions
This camera is intended for use in the electromagnetic environment specified
below. The customer or the user of this camera should assure that it is used in such
an environment.
Emissions test
Compliance
Electromagnetic environment -
guidance
RF emissions
CISPR 11
Group 1
This camera uses RF energy only for its
internal function. Therefore, its RF
emissions are very low and are not
likely to cause any interference in
nearby electronic equipment.
RF emissions
CISPR 11
Class B
The camera is suitable for use in all
establishments other than domestic,
and may be used in domestic
establishments and those directly
connected to the public low-voltage
power supply network that supplies
buildings used for domestic purposes,
provided the following warning is
heeded:
Warning:
This camera is intended for use by
healthcare professionals only. This
camera may cause radio interference or
may disrupt the operation of nearby
equipment. It may be necessary to take
mitigation measures, such as re-
orienting or relocating the camera or
shielding the location.
Harmonic
emissions
IEC 61000-3-2
Class A
Voltage
fluctuations/
flicker emissions
IEC 61000-3-3
Complies
DEXcam4 HD EN.book Page 10 Monday, January 16, 2017 2:12 PM