TEL: +886 2 86984245
FAX: +886 2 86984108
Add: 15F, No.81,Sec.1, Hsin Tai Wu Rd.,Hsi-Chih 221, Taipei Hsien, Taiwan
DEXATEK TECHNOLOGY LTD.,
TEL: +886 2 86984245
FAX: +886 2 86984108
Test report
1. Specification
1.1 SA-7101 Spec
Item
Spec Item
Spec Value
Electrical
Radio Carrier Frequency
2.4G
Operating Distance
30M in Open spaces
Battery Requirement
AAA batteries x2pcs
Operation Voltage
3V
Power consumption
0.186mA
2. Environmental Requirement
Test Equipment
Equipment :
Temperature Test Chamber
Manufacturer :
KSON
Model Number :
THS-C2T-100
Date of Calibration :
Jul. 8, 2013
Laboratory Ambiance Condition
Temperature :
15 ~ 35
℃
Humidity :
25 ~ 75 %RH
2.1 Temperature & Humidity Test:
Chamber settings
Test Device
0 ºC
the data cannot refer when the temperature was below to 0 ºC
0 ºC
1.8 ºC 32%
-5 ºC
-4 ºC 36%
-10 ºC
-8.9 ºC 30%
-15 ºC
-13.7 ºC 42%
-20 ºC
-18.7 ºC 49%
20 ºC
20%
20 ºC 23%
30%
20 ºC 30%