Dewhot NDCT16DH Скачать руководство пользователя страница 18

Page 18 of 30

Dewhot 

| Gas geyser manual

GENERAL MAINTENANCE 

 

If your gas technician maintains your gas 

geyser you should not have any issues with 

it for years.

We recommend that you periodically check 

the burner, relief valve, water filter and flue 

system. 

 

This needs to be done by a certified installer. 

A  maintenance program is advisable.

1.  Inspect the area around the gas  

geyser to ensure that its in a safe  
operating environment. 

2.  Make sure that the appliance has not 

been damaged. If there are traces 
of damage or denting contact your 
supplier to check that the appliance is 
still functioning properly.

3.  Check for any abnormal sounds while 

operating your appliance. A light 
humming sound is normal from time to 
time. 
Check for gas/ water leaks.

4.  The cold water supply filters should be 

cleaned once a year. 

5.  Perform regular maintenance on the 

geyser to prevent carbon monoxide 
dangers, excessive hot water 
temperatures or other potentially 
hazardous conditions.

DO NOT

1.  Continue to use the gas geyser if you feel 

that there is something wrong with it.

2. Allow children to operate or handle  

the appliance. 

After you have checked, maintained and/

or cleaned the appliance, make sure that it 

is working properly by turning on the hot 

water tap. 

COASTAL CORROSIVE 

ENVIROMENTS 

For geysers installed near the coast, get 
your gas installer to remove the cover and 
spray electrical contact cleaner on all the 
electronic contacts, after the electrical spray 
has dried up you can spray Q30 or any other 
kind of electrical sealant to seal the joins 
and prevent corrosion from entering the 
electronics. This is highly advised and can be 
performed at any location inland or coastal. 
Do not perform this step if the geyser is on. 

Maintenance and cleaning 

Содержание NDCT16DH

Страница 1: ...16lt Constant Temperature...

Страница 2: ......

Страница 3: ...ier immediately Burn back In the event of a burn back where the flame burns back to the jet immediately turn the gas supply off at the gas cylinder After ensuring the flame is extinguished wait for I...

Страница 4: ...Page 4 of 30 Dewhot Gas geyser manual Parts Diagram LCD screen Controller box LCD screen Pilot assembly Pilot jet Gas valve Battery Box Pilot tube Burner Washer Burner Jet Bar Test Point...

Страница 5: ...Page 5 of 30 Dewhot Gas geyser manual Outlet Temp sensor 850 C Temp sensor 1100 C Temp sensor Cover Chimney box Inlet water valve Water flow sensor Inlet Temperature sensor Radiator...

Страница 6: ...meters Description Constant temperature Model no NDCT16DH Model Type D Gas type LPG Max gas pressure 2 8kpa Rated input 32kw Water pressure 20 500 kPa Maximum Water Flow 16L min Max Gas Consumption 2...

Страница 7: ...SERS Use this gas geyser in conjuction with our solar to gas valve to boost your solar water temperature in the winter months or colder cloudier summer days FLAME OUT SENSOR This is designed to automa...

Страница 8: ...and energy savings need to be considered when setting the water temperature Water temperatures above 52 C can cause severe burns Refer to page 16 1 Households with small children disabled or elderly...

Страница 9: ...witch 4 Evacuate the house immediately with your family and pets 5 Leave the doors open for ventilation and contact the gas supplier registered LP Gas Installer or Fire Department 6 Stay away from the...

Страница 10: ...in a place that allows for easy access for future servicing and replacing batteries Use at least 8mm concrete plugs and screws to mount the gas geyser to the wall In the case of dry walling use dry wa...

Страница 11: ...1 For long pipe runs water pressure can drop and additional water pressure may be required 2 When the water is supplied from a water tank the height of the tank the diameter of the pipes and their rel...

Страница 12: ...e gas geyser for service and draining purposes Installation of demountables is recommended on the hot and cold water lines so that the gas geyser may easily be disconnected for servicing Install a non...

Страница 13: ...appliance If such flammables must be used open doors and windows for ventilation 5 Appliances in the vicinity should be shut off to avoid vapours igniting from the gas burner Flammable vapours can be...

Страница 14: ...nder and any gas shut off valves installed on the gas line There may be an air lock inside the gas line especially for gas piping which is longer than three to five meters To get rid of this airlock y...

Страница 15: ...f the gas geyser in the event of a hot water leakage the geyser will not turn on The body of the gas geyser can get hot during operatuon do not touch any part of the gas geyser except for the control...

Страница 16: ...aximum water temperatures are reached The water temperature is determined by turning on a hot water tap Water temperatures at the tap will vary depending on the weather and length of piping from the g...

Страница 17: ...with your hand before use and remember that hotter water settings increase the risk of injury The gas geyser is fitted with a device that will shut off the gas supply to the burner if the appliance ex...

Страница 18: ...filters should be cleaned once a year 5 Perform regular maintenance on the geyser to prevent carbon monoxide dangers excessive hot water temperatures or other potentially hazardous conditions DO NOT 1...

Страница 19: ...brush and rinse it with running water Put the filter back and screw it in Turn on the second the cold water supply CAUTION Cleaning of the main burner should always be performed by Registered LPG Ins...

Страница 20: ...time Unit fires continuously without a flame coming on or showing an error Faulty controller Faint firing and PA BA or 6A comes up on the screen Flat batteries The geyser flame comes on and runs up t...

Страница 21: ...section is faulty check the first and second stage solenoids with a voltmeter Unit suddenly goes cold during use Batteries may be flat Regulator is delivering too high a gas pressure unit shuts off h...

Страница 22: ...t operation of the appliance again IF THE ERROR CODE IS STILL SHOWN Turn off the hot water tap and turn off the switch on the LCD Take note of the error code displayed and call the Dewhot Technical Se...

Страница 23: ...agm valve or controller E1 No flame signal detected within 60s on the pilot flame No flame signal detected within 10s on the main burner Check the gas inlet pressure is operating at 2 8 kPa Check whet...

Страница 24: ...r Change the outlet temp sensor Change the diaphragm valve or controller E7 The gas flow is unstable and has switched off 5 times continuously It is normal if it is the first time operation or the app...

Страница 25: ...is pulled off burnt or damaged Change the input water temperature sensor EB One of the 2 CPUs of the controller is damaged Change the loom to gas valve Change the loom to LCD Change the LCD screen Cha...

Страница 26: ...operational and safety briefing Before you sign off the installation make sure you also receive your COC Installer This appliance may only be installed by a LPG Installer registered with the South Af...

Страница 27: ...Page 27 of 30 Dewhot Gas geyser manual...

Страница 28: ...Page 28 of 30 Dewhot Gas geyser manual www dewhot com...

Страница 29: ...www dewhot com...

Страница 30: ...16lt Constant Temperature...

Отзывы: