13

DEWE2-M13s • Technical Reference Manual • Printing version 1.0.2 • June 27, 2017

MAINTENANCE

Maintenance

The information in this section is designed for use by qualified service personal.

Service interval:

Clean dust from the chassis exterior/interior and exchange filter foam based on the operating environment.

Cleaning:

Clean surface of the chassis with dry lintfree cloth.

 

Use a dry velocity stream of air to clean the chassis interior.
   

> Disconnect all cables before servicing the unit!

 

   

> Many components within the chassis are sensitive to static discharge damage. Always wear a    

 

     

   ground wrist strap and service the unit only in static-free environment.

 

   

> Do not use harsh chemical cleaning agents!

!

Содержание DEWE2-M13s

Страница 1: ...with accurate complete and reproducible measurement results for your decision making Look forward to the easy handling and the flexible and modular use of your DEWETRON product and draw upon more than 25 years of DEWETRON expertise in measurement engineering ISO9001 EN ISO 14001 COMPETENT MODULAR APPROVED CUSTOMIZED COMMITTED ...

Страница 2: ...ht All rights are reserved Reproduction adaptation or translation without prior written permission is prohibited except as allowed under the copyright laws All trademarks and registered trademarks are acknowledged to be the property of their owners DEWESoft is a trademark of Dewesoft d o o ...

Страница 3: ...d information about keeping your DEWETRON system in good working condition over time We strongly suggest that you read this entire manual especially the safety and care sections as well as to avoid damaging your DEWETRON system What is the DEWE2 M13s This product has 13 slots for user exchangeable TRION series modules and is used for measuring of different physical and or electrical sizes dependin...

Страница 4: ...4 PREFACE Notes ...

Страница 5: ... General safety and hazard warnings for all DEWETRON systems 10 Maintenance 13 Windows updates and antivirus security software 14 Problematic network stacks 14 Environmental Considerations 14 Main System 15 DEWE2 M13s portable data acquisition mainframe 15 System specifications 15 DEWE2 M13s at a glance 17 Installing a TRION module in the chassis 20 Power supply 21 Maintenance 23 System recovery 2...

Страница 6: ...6 TABLE OF CONTENT Notes ...

Страница 7: ...least one year so calibration reports can be purchased for up to one year after your system was delivered Support DEWETRON has a team of people ready to assist you if you have any questions or any technical difficulties regarding the system For any support please contact your local distributor first or DEWETRON directly For Asia and Europe please contact For the Americas please contact DEWETRON Gm...

Страница 8: ...e of the information in this document Warranty Information A copy of the specific warranty terms applicable to your DEWETRON product and replacement parts can be obtained from your local sales and service office Restricted Rights Legend Use austrian law for duplication or disclosure DEWETRON GmbH Parkring 4 A 8074 Grambach Austria TRION is a trademark of DEWETRON GmbH Any other trademarks and regi...

Страница 9: ...ntion to a procedure practice or condition that could cause bodily injury or death CAUTION Calls attention to a procedure practice or condition that could possibly cause damage to equipment or permanent loss of data WARNINGS The following general safety precautions must be observed during all phases of operation service and repair of this product Failure to comply with these precautions or with sp...

Страница 10: ...r grounding please refere to your local legally safety regulations for safety use DC systems Every DC system has a grounding connected to the chassis yellow green safety banana plug Please note the characteristics and indicators on the system to avoid fire or electric shocks Before connecting the system please carefully read the corresponding specifications in the product manual The inputs are not...

Страница 11: ...a perilous electric shock by touching the wiring Maximum input voltage for measuring cards are 70 VDC and 46 7 VPEAK The product heats during operation Make sure there is adequate ventilation Ventilation slots must not covered Only fuses of the specified type and nominal current may be used The use of patched fuses is prohibited Prevent using metal bare wires Risk of short cut and fire hazard DO N...

Страница 12: ...eft the factory in safety related flawless and proper condition In order to maintain this condition and guarantee safety use the user has to consider the security advices and warnings in this manual EN 61326 3 1 2008 IEC 61326 1 applies to this part of IEC 61326 but is limited to systems and equipment for industrial applications intended to perform safety functions as defined in IEC 61508 with SIL...

Страница 13: ...erior and exchange filter foam based on the operating environment Cleaning Clean surface of the chassis with dry lintfree cloth Use a dry velocity stream of air to clean the chassis interior Disconnect all cables before servicing the unit Many components within the chassis are sensitive to static discharge damage Always wear a ground wrist strap and service the unit only in static free environment...

Страница 14: ...imary function of the DEWETRON system to record data Therefore we recommend strongly against the installation of IT MIS software and running their processes on any DEWETRON data acquisition system and cannot guarantee the performance of our systems if they are so configured Environmental Considerations Information about the environmental impact of the product Product End of Life Handling Observe t...

Страница 15: ...r supply and cable included 18 to 21 VDC isolated DC input 3 batteries for appr 2 hours operation included Typical power consumption 300 W Operating temperature 0 C to 50 C Operating temperature with option DW2 PS BAT 0 C to 50 C when discharging batteries 0 C to 45 C when charging batteries Storage temperature 20 C to 70 C Humidity operating 10 to 80 non condensing 5 to 95 rel humidity Altitude u...

Страница 16: ...16 15 177 17 441 18 387 230 21 34 80 74 21 6 103 24 237 MAIN SYSTEM Dimensions Dimensions in mm 1 inch 25 4 mm ...

Страница 17: ...tem configuration 1 Power supply input connector 2 Chassis terminal 3 TRION SYNC BUS 4 Power supply for accessories 12 VDC 1 5 A 5 Remote power on connector optional 6 PCI express X1 interface 7 USB interface connectors 8 GBit Ethernet LAN connector 9 Audio interface MIC SPEAKER 10 TRION series module slots 11 RS232 interface connector COM 1 12 VGA interface connector 13 PS 2 connector 14 Power on...

Страница 18: ...h an 1 5 A self recovering fuse Lemo EGG 1B 302 Mating connector LEMO FGG 1B 302 CLAD52Z for cable diameter 4 1 to 5 0 mm LEMO FGG 1B 302 CLAD62Z for cable diameter 5 1 to 6 0 mm 5 Remote power on connector optional 6 PCI express X1 interface Upstream Downstream The DEWE2 M13s is equipped with a PCI express X1 interface by default to to enable daisy chaining of units in combination with the TRION ...

Страница 19: ...nector meets standard VGA pin assignment 13 PS 2 connector The PS 2 connector is used to connect a mouse keyboard to the DEWE2 M13s The connector meets standard PS 2 pin assignment 14 Power on switch The power on switch has to be used to switch on the system 15 WLAN antenna The DEWE2 M13s supports 802 11 b g n WLAN standards 16 EPAD connector LEMO To connect DEWETRON EPAD modules to the system 1 2...

Страница 20: ...t Some modules require a TRION STAR slot For more information please see chapter STAR slot for TRION modules Step 4 Remove the filler panel of an unused TRION peripheral or STAR slot Step 5 Place the module edges of the TRION modules into the module guides at the top and bottom of the chassis Step 6 Insert the TRION module to the rear of the chassis until a resistance appears Step 7 Pull up on the ...

Страница 21: ... Power supply pin assignment Connector type 2 pin male LEMO EGJ 2B 302 NOTE If the system is powered by batteries please take care that there are at least 3 batteries installed In some special applications 4 batteries are necessary Hot swap of the batteries not possible WARNING It is only allowed to use battery packs from Inspired Energy with the labelling NH2054HD34 Otherwise the system won t wor...

Страница 22: ... auto recovery after temp has fallen Yes Setup time 2000ms 230VAC 4000ms 115VAC Rise time 100ms 230 VAC 100ms 115 VAC Holdup time 16ms 230 VAC 16ms 115 VAC Withstand voltage I P O P 3 KVAC I P FG 1 5 KVAC O P FG 0 5 KVAC 1 minute Isolation resistance I P O P I P FG O P FG 500 VDC 100 MOhm Switching frequency 100 kHz Temperature Operating Derating Storage 10 to 65 C 45 to 60 C 2 C 3 5 5 V 40 to 65 ...

Страница 23: ... M5x8 Left assembly bracket Right assembly bracket M5x8 M5x8 M5x8 M5x8 M5x8 M5x8 WARNING When installing the 19 mounting brackets the maximum lenght for screws is 8 mm If any screw get lost replace it with M5x8 countersunk head screw only Otherwise the TRION series cards or the powersupply could get damaged System recovery For more information regarding a total recovery please refer to the corresp...

Страница 24: ...tained to ensure proper cooling of the chassis power supply as well as the modules plugged into the chassis NOTE When installing the DEWE2 M13s into a 19 cabinet please keep in mind that the unit is siphoning air from the bottom see schematic above Due to this circumstances 5 u are required for one system 4 u system 1 u cooling Otherwise the system may overheat and could get damaged cool air in ho...

Страница 25: ...ing EC directives 2014 35 EU Directive of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to the making available on the market of electrical equipment designed for use within certain voltage limits 2004 108 EC Directive on the approximation of the laws of the Member States relating to electromagnetic compatibility amend...

Страница 26: ...C2 NOTES ...

Отзывы: