background image

DS-CAM-640c & DS-CAM-1100m

TECHNICAL REFERENCE MANUAL

This product has been classified as Monitoring and Control equipment and is outside the scope of the
2002/95/EC RoHS Directive. However, we take care of our environment and the product is lead-free.

8.2.4. General safety and hazard warnings for all Dewesoft systems

Safety of the operator and the unit depend on following these rules.

Use this system under the terms of the specifications only to avoid any possible danger.

Read your manual before operating the system.

Observe local laws when using the instrument.

DO NOT touch internal wiring!

DO NOT use higher supply voltage than specified!

Use only original plugs and cables for harnessing.

You may not connect higher voltages than rated to any connectors.

The power cable and connector serve as Power-Breaker. The cable must not exceed 3 meters, the
disconnect function must be possible without tools.

Maintenance must be executed by qualified staff only.

During the use of the system, it might be possible to access other parts of a more comprehensive
system. Please read and follow the safety instructions provided in the manuals of all other
components regarding warning and security advice for using the system.

With this product, only use the power cable delivered or defined for the host country.

DO NOT connect or disconnect sensors, probes or test leads, as these parts are connected to a
voltage supply unit.

Ground the equipment: For Safety Class 1 equipment (equipment having a protective earth
terminal), a non-interruptible safety earth ground must be provided from the mains power
source to the product input wiring terminals.

Please note the characteristics and indicators on the system to avoid fire or electric shocks. Before
connecting the system, please read the corresponding specifications in the product manual
carefully.

The inputs must not, unless otherwise noted (CATx identification), be connected to the main
circuit of category II, III and IV.

The power cord separates the system from the power supply. Do not block the power cord, since
it has to be accessible for the users.

DO NOT use the system if equipment covers or shields are removed.

If you assume the system is damaged, get it examined by authorized personnel only.

Adverse environmental conditions are Moisture or high humidity Dust, flammable gases, fumes
or dissolver Thunderstorm or thunderstorm conditions (except assembly PNA) Electrostatic fields,
etc.

The measurement category can be adjusted depending on module configuration.

Any other use than described above may damage your system and is attended with dangers like
short-circuiting, fire or electric shocks.

The whole system must not be changed, rebuilt or opened.

DO NOT operate damaged equipment: Whenever it is possible that the safety protection features
built into this product have been impaired, either through physical damage, excessive moisture,
or any other reason, REMOVE POWER and do not use the product until the safe operation can be
verified by service-trained personnel. If necessary, return the product to Dewesoft sales and
service office for service and repair to ensure that safety features are maintained.

If you assume a more riskless use is not provided anymore, the system has to be rendered
inoperative and should be protected against inadvertent operation. It is assumed that a more
riskless operation is not possible anymore if the system is damaged obviously or causes strange

DS-CAM-640c & 1100m V22-1

30/34

Содержание DS-CAM-1100m

Страница 1: ...DS CAM 640c 1100m TECHNICAL REFERENCE MANUAL DS CAM 640c 1100m V22 1...

Страница 2: ...2 SIRIUS with DS CAM 11 4 5 3 SBOX SIRIUS with DS CAM 11 4 5 4 KRYPTON connection example 12 4 5 5 Multi camera solution 12 4 5 Resolutions Framerates 13 5 Installation and start up 14 5 1 DewesoftX...

Страница 3: ...ranty information 27 7 1 Calibration 27 7 2 Support 27 7 3 Service repair 27 7 4 Restricted Rights 27 7 5 Printing History 27 7 6 Copyright 28 7 7 Trademarks 28 8 Safety instructions 29 8 1 Safety sym...

Страница 4: ...ymbols and formats will be used throughout the document Important It gives you important information about the subject Please read carefully Hint It gives you a hint or provides additional information...

Страница 5: ...alance PTP Synchronization Standard C mount lens mounting Small form factor Rugged aluminum housing high shock and vibration resistance The camera supports the high performance industrial standard Gig...

Страница 6: ...ce SSD storage disc DewesoftX 2022 1 or newer GigE plugin V7 7 or newer The latest OptoStream SDK Dewesoft GigE driver cdv 3 1 2 Optimal configuration 1x 10 Gigabit Ethernet port High performance PC C...

Страница 7: ...ACC CI M12MS 12CON L180 Synchronisation SoftSync 1 5ms 1 frame PTP Ready SoftSync 1 5ms 1 frame PTP Ready Optical specifications Type Color Monochrome Image sensor Sony IMX252 Sony IMX421 Gen3 Sensor...

Страница 8: ...midity 10 90 non condensing 10 90 non condensing IP rating IP40 with mounted lens and 10 GigE cable IP65 67 with mounted tube and cable IP40 with mounted lens and 10 GigE cable IP65 67 with mounted tu...

Страница 9: ...DS CAM 640c DS CAM 1100m TECHNICAL REFERENCE MANUAL 4 2 DS CAM 640c DS CAM 1100m Dimensions Image 1 Technical drawing of DS CAM 640c DS CAM 1100m DS CAM 640c 1100m V22 1 6 34...

Страница 10: ...for ambient temperatures above 30 C Signal transfer CABLE GigE M12X RJ45 5 0m 5m M12X to RJ45 CAT6A signal cable Power transfer L1B2m M1212 5m 5m M1212 to L1B2m power cable compatible with SIRIUS PS 1...

Страница 11: ...onnectors Lemo L1B2f PHG Country wall socket Power 120 W 24 V 5 A Fits DS CAM 640c DS CAM 1100m Cable length 3 m 1 5 m to adapter 1 5 m from adapter Multi camera power splitter POWER SPLITTER 1xL1B2m...

Страница 12: ...7 MX3 8 MX3 Camera connector SACC CI M12FS 8CON L180 10G 4 4 2 POWER CONNECTOR PINOUT Image 5 IO connector pin out M12 12 pin a coded Camera connector SACC CI M12MS 12CON L180 Pin Name 1 Power Vcc 2 G...

Страница 13: ...or DS CAM 640c DS CAM 1100m Keep in mind that the synchronization between other devices is done by SoftSync with a precision of 1 5 ms 1 frame 4 5 1 Stand alone DS CAM The most basic of configurations...

Страница 14: ...CAM In this configuration a SIRIUS Data Acquisition Device is used connected to an SBOX The DS CAM is connected to the SBOX over one of its two LAN ports In such configuration power can be provided e...

Страница 15: ...nfiguration is not much different from a typical SIRIUS configuration but in this case we recommend also using DS CAM IP65 COVER for added protection Image 9 KRYPTON based system 4 5 5 Multi camera so...

Страница 16: ...20 330 FPS 380 FPS XGA 1024 x 768 415 FPS 490 FPS SVGA 800 x 600 520 FPS 690 FPS VGA 640 x 480 640 FPS 1100 FPS QVGA 320 x 240 1150 FPS 1900 FPS Maximum Frame rate measurements were done 8bit resoluti...

Страница 17: ...the DewesoftX online manual Disabling unneeded options and filters and adjusting Jumbo packets Receive Buffer size might solve your issues 5 1 DewesoftX full installer If you run a fresh full install...

Страница 18: ...the version is 7 6 or more If not update DewesoftX on Options Check for updates or execute the full installer again When the installer starts up choose the Modify option and proceed to the next step...

Страница 19: ...m TECHNICAL REFERENCE MANUAL Image 12 Installing GigE camera driver and OptoStream GEV Filter The last DewesoftX full installer can be downloaded here https download dewesoft com list dewesoftx DS CAM...

Страница 20: ...ghts DewesoftX Available from https download dewesoft com list dewesoftx Hint You need to be logged into the Dewesoft website to download the latest development versions of DewesoftX 5 3 2 Adding GigE...

Страница 21: ...ed network settings Used Ethernet card Properties Hint Note that Filter Driver filters out all packets that are not GigE on the hardware level so the camera will work much faster than without the filt...

Страница 22: ...M 1100m support DHCP so connecting them to a managed network should be a straightforward procedure Open the OptoStreamViewer to check if all of the connected cameras are recognized and working by sele...

Страница 23: ...If you are having issues with camera recognition use the IP Config Tool on the below link for discovery and configuration https drive google com file d 1ydFkvtvzKP6TUmuXw382toHSYIQkI6_Z view usp shar...

Страница 24: ...tware White balance is used for color source correction The JPEG quality is inverse to the compression 80 means good quality low compression To improve the performance if using the camera on an Ethern...

Страница 25: ...by GetEnvironmentVariable PATH 6 3 No picture shown No frames received error If you receive the error NO FRAMES RECEIVED check Try decreasing the Shutter value Check under Settings if the DewesoftUSB...

Страница 26: ...in DewesoftX close it and start OptoStreamViewer for troubleshooting 6 6 Change the IP address of the camera Image 21 Change the IP address of the camera If you manually change the IP address please...

Страница 27: ...SDK GenICam_v2_4 bin Win64_x64 to Windows system32 respectively Windows SysWOW64 Then start the OptoStreamViewer from C Program Files OptoMotive OptoStreamSDK bin Win64 6 8 Cameras not working in Dewe...

Страница 28: ...cable used between the camera and the PC is at least CAT5 quality For longer cable lengths CAT6 cable should be used for optimal performance For this camera the best quality can be achieved by using...

Страница 29: ...vanced Jumbo Frame set to highest value e g 9kB MTU Also an overloaded DewesoftX setup many displays e g high resolution FFT instruments will take system power Try at first only with camera video inst...

Страница 30: ...vals The standard norm across nearly every industry is annual calibration Before your Dewesoft data acquisition system is delivered it is calibrated Detailed calibration reports for your Dewesoft syst...

Страница 31: ...roducts and we take care that all key products and technologies are registered as trademarks all over the world The Dewesoft name is a registered trademark Product families KRYPTON SIRIUS DSI DS NET a...

Страница 32: ...ll accessories shown in this document are available as an option and will not be shipped as standard parts 8 2 1 Environmental Considerations Information about the environmental impact of the product...

Страница 33: ...inals Please note the characteristics and indicators on the system to avoid fire or electric shocks Before connecting the system please read the corresponding specifications in the product manual care...

Страница 34: ...transmitting antennas or high frequency generators for exact values please refer to enclosed specifications Use measurement leads or measurement accessories aligned with the specification of the syst...

Страница 35: ...er electromagnetic environments for example in the process industry or in environments with potentially explosive atmospheres are excluded from the scope of this product family standard IEC 61326 3 1...

Страница 36: ...PC Image 8 SBOX based system with SIRIUS and DS CAM Image 9 KRYPTON based system Image 10 Configuration with multiple cameras over a switched network Image 11 Modification of installation Image 12 Ins...

Страница 37: ...CAM 640c DS CAM 1100m TECHNICAL REFERENCE MANUAL 11 NOTES A table for data entry when you are setting up larger systems No CAM Type IP MAC Notes 1 2 3 4 5 6 7 8 9 10 11 12 DS CAM 640c 1100m V22 1 34...

Страница 38: ......

Отзывы: