78438 7.0
5.2 Installing the ID21 lifting columns
Before installing and connecting the ID21 lifting columns, make sure that you are observing all
of the safety notices found in the "Safety notices to observe during installation" section.
5.2.1 Installing the table base
Use M6 bolts (with strength grade 8.8), as shown in Figure17. The tightening torque is 10 Nm.
Figure17
Mounting the table base (dimensions in mm)
A
Base plate
B
M6 bolts (8.8)
C
Foot of the lifting column
B
C
A
min. 9, max. 11
50
35
C