The lying surfaces and the underframe are not anti-static as standard. 
 
Our products are not intended for use in wet rooms and must under no circumstances be cleaned using so-
called bed washers. This would irreparably destroy the product. 

 

The head part and armrests are only intended to support the patient and must not be used for sitting. 

 

If the underframe is designed with movability (optional), all the castors must always be locked before using 
the table.  
 
Do not put a damaged device into operation. 
 
Disconnect the device from the mains (power supply) in the event of a fault or during maintenance work. 
To disconnect, be sure to grasp the plug, not the power cable. 
 
This device must not be modified without the express permission of the manufacturer. 

 
 
1.8 Model designation and type labelling 

The exact model designation depends on the choice of frame colour:  

-03 white aluminium powder coated (RAL 9006); 
-04 grey aluminium powder coated (RAL 9007) 

 
The type plate is attached to the underframe on one long side of the table. It provides information about key 
table data. 
The following symbols are listed there (by way of example), their meanings are: 
 

 
Read the operating 
manual   

 
     Serial no. 

 
Applied part Type B  

                   
Caution, potential 
hazard 

 
Max. load 
capacity 

 
    CE mark 
 

 
Date of manufacture 

      
     Product may only  
     be used in dry  
                        rooms 

 
  Do not dispose of with  
  household waste 

 
Address of 
manufacturer 

 
        Protection class I 

 

 
 

1.9 Meaning of the serial number 

The serial no. is located on the type plate or is shown separately next to the type plate of the table. This 
number is unique and firmly linked to this specific individual product. It enables us to identify this table model 
and trace back assemblies/safety-relevant components at any time.  
Please always state this serial number when enquiring about spare parts.  
 
 

2. Operating manual 

 

2.1 Table design 

When designing the table frames, special emphasis was placed on functional and operational safety. The 
number of possible pinching points has thus been minimised, while remaining ones have been covered or 
protected with spacers to prevent injury, thus ensuring safe and yet simple operation. Nevertheless, 
necessary caution must always be exercised when using the table. 

 

 

 

Содержание 6000E Series

Страница 1: ...ntended purpose 2 1 5 Information on setup and use 3 1 6 Commissioning 3 1 7 Safety instructions 3 1 8 Model designation and type labelling 4 1 9 Meaning of the serial number 4 2 Operating manual 4 2...

Страница 2: ...th the contents of these instructions for use before using the device We recommend that you keep these instructions for use near the device for future reference The device may only be used by authoris...

Страница 3: ...y Remove the power cable from the film packaging on the underframe of the table and connect it properly to a permanently installed mains socket When routing the power cable make sure the cable cannot...

Страница 4: ...attached to the underframe on one long side of the table It provides information about key table data The following symbols are listed there by way of example their meanings are Read the operating ma...

Страница 5: ...as spring the head part must not be used for sitting Head part adjustment upwards and downwards positive and negative direction using a gas spring The head part is adjusted using a gas spring To opera...

Страница 6: ...l lifting fixing mechanism is not controlled centrally a foot lever must be operated on each short side of the table in order to lower the table onto its feet or to place it on the castors This option...

Страница 7: ...ort plate and removable upholstery The upholstery is attached to the frame using hook and loop tape on the sides To do this affix the tape on the underside of the frame The upholstery can be removed f...

Страница 8: ...te rest period There is therefore no risk of overloading the motor The mechanics of the tables have been designed with extensive safety margins in mind The max patient weight is provided with a 4 fold...

Страница 9: ...pid exchange of air is necessary To ensure this there are individual vent points on the underside of the upholstery which are hygienically sealed with special air compensation caps that assume a valve...

Страница 10: ...on In the event of any abnormalities take the table out of service immediately and inform the operator Replace damaged or worn components immediately and do not use the table until it has been repaire...

Страница 11: ...d to the manufacturer K H Dewert GmbH and to the competent authority of the Member State in which the user and or the patient resides Member State Competent authority Web Estonia Health Board Tervisea...

Страница 12: ...s later on the no longer used product must be rendered unusable immediately e g by disconnecting the power cable Please observe the local regulations for waste disposal and preferably recycle the mate...

Страница 13: ...fessionally trained persons who have been instructed in its use or who through experience with other similar medical devices have knowledge of its proper use taking into account possible hazards The d...

Страница 14: ...All switches and supply lines undamaged Function check With electromotive adjustment Move all motors with the foot switch or the hand switch to both limit positions until automatic switch off to ensu...

Страница 15: ...ntral locking system also the grub screws of switch levers Safe braking effect Check with locked brakes by pulling and pushing the table Structural inspection Check screw connections Retighten all scr...

Отзывы: