background image

1.6

 

Foot down button 8 

Press and hold

 Foot

 DOWN button of remote,

 Foot

 actuator moves in, stop when released

 

1.7

 

Flat button 15 

Click FLAT button, the bed goes flat, stop when click any button during the process of going 

flat

 

1.8

 

Massage all 3 

Click 

Massage  all

  button,  all  massage motor switches massage intensity, massage 

intensityswitches among 0-1-2-3

 

1.9

 

M3/M4 motor up button 11 

Press and hold

 M3/M4

 UP button of remote,

 M3/M4

 actuator moves out, stop when released

 

1.10

 

M3/M4 motor down button 12 

Press and hold

 M3/M4

 down button of remote,

 M3/M4

 actuator moves in, stop when released

 

1.11 Memory position button 10 and 13 14 

Click memory position to move the actuator to the memory position. 

Press and hold the button for 5s, timer LED of remote flashes, the control box records current 

position as the memory position; 

3

 / 

4

 

Содержание RF405B

Страница 1: ...hor User Manual of RF405B Edition 1 0 Page 1 of 4 User Manual of RF405B Figure 1 button ofremote Underbed Light ZEROG position Head Down M3 M4 up Head Up Antisnore EXTME1 position Flat Lounge position Foot down EXTME2 position Foot up MassageALL Sensor light M3 M4 down 1 4 ...

Страница 2: ...ntiSnore position stop when click any button during movement Press and hold AntiSnore button for 5s timer LED of remote flashes the control box records current position as AntiSnore position When in the process of moving to memory positions the head and foot actuators move first then the tilt and lumbar actuators move 1 3Head up button 4 Press and hold HEAD UP button of remote head actuator moves ...

Страница 3: ...y massage intensityswitches among 0 1 2 3 1 9 M3 M4 motor up button 11 Press and hold M3 M4 UP button of remote M3 M4 actuator moves out stop when released 1 10 M3 M4 motor down button 12 Press and hold M3 M4 down button of remote M3 M4 actuator moves in stop when released 1 11 Memory position button 10 and 13 14 Click memory position to move the actuator to the memory position Press and hold the ...

Страница 4: ...e and Economic Development Canada licenceexempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Le présent appareil est conforme aux CNR d ISED applicables aux appareils radioexempts de licence L exploitation est autoris...

Отзывы: