E
ng
lish
3
Specifications
CONTENTS
WARNINGS ........................................................................ 2-3
HEATER SPECIFICATIONS ................................................... 3
OPERATING PRECAUTIONS ................................................ 4
SAFETY PRECAUTIONS ....................................................... 4
ODOR FADE WARNING ..................................................... 5-6
OPERATING INSTRUCTIONS ............................................... 6
MAINTENANCE, STORAGE AND SERVICE ......................... 7
WIRING DIAGRAMS .............................................................. 8
PARTS LISTS/EXPLODED VIEWS .................................... 9-12
WARRANTY ......................................................................... 13
INSTRUCTIONS FOR ORDERING PARTS .......................... 13
WARNING: RISK OF FIRE OR EXPLOSION
• Do not store or use gasoline or other flammable vapors and liquids in
the vicinity of this or any other appliance.
• WHAT TO DO IF YOU SMELL GAS:
• Open windows.
•
DO NOT
try to light any appliance.
•
DO NOT
operate any electrical switches.
•
DO NOT
use any telephone in building. Immediately call the
local gas supplier from an outside telephone. Follow the gas
supplier’s instructions.
•
DO NOT
touch any electrical switch; do not use any phone in your
building.
• If you cannot reach your gas supplier, call the Fire Department.
Model:
DXH125FAV
DXH150FAV
Rating:
75,000 - 125,000 Btu/Hr
110,000 - 150,000 Btu/Hr
(21.9 – 36.6 kW)
(32.2 – 43.9 kW)
Fuel Consumption:
3.5 – 5.8 #/hr
5.1 – 6.9 #/hr
(1.59 – 2.63 kg/hr)
(2.31 – 3.13 kg/hr)
Fuel Orifice Size
1.26 mm
1.40 mm
SPECIFICATIONS
Type of Gas: ..............For use with Propane Only
Gas Supply Pressure
to regulator .............Max.: Bottle Pressure
to regulator .............Min.: 5 psig (34.5 kPa)
regulator out ..........27.5" W.C. (6.84 kPa)
Electrical Input: ..........115V, 60 Hz, 1Ø, 3a
Min. Operating Voltage: 100V
Ignition: ......................Direct Spark
Primary
Flame Control: .........Thermocouple Operated Gas Valve
High Temperature
Control: ....................240°F (116°C)
Min. Ambient Temp. Rating 0°F (-17.8°C)
Содержание DXH125FAV
Страница 10: ...English 10 DXH125FAV ...
Страница 12: ...12 English DXH150FAV ...
Страница 14: ......
Страница 24: ...Français 10 DXH125FAV ...
Страница 26: ...12 Français DXH150FAV ...
Страница 37: ...Español 10 DXH125FAV ...
Страница 39: ...12 Español DXH150FAV ...