7 Operation
27
7.11 Stopping
See image above
1.
Switch off all electrical equipment and tools and disconnect from the
generator.
2.
Let the engine run without load for 2-3 minutes to cool it down.
3.
Put the engine switch in the "OFF" position
(c2)
.
4.
Close the fuel shut-off valve.
Comment
:
To turn off quickly in cases of emergency, put the engine switch in the
"OFF" position
(c2)
.
7.12 Emergency stop procedure
Procedure
In the case of an accident of a failure of the machine during operation, the following
procedure is to be applied:
1.
Stop the engine.
2.
Shut off the fuel supply.
3.
Disconnect the tools from the machine.
4.
Let the machine cool.
5.
Please contact the machine rental or machine owner for additional manuals.