9
GB
Error Codes
If INFO appears on the display window with a Code number, perform the corresponding Corrective Action.
Code
Description
Corrective Action
101
Received Signal Too Weak,
Measuring Time Too Long
Use the target plate or change the target surface.
102
Received Signal Too High
Target is too reflective. Use the target plate or change the target
surface.
201
Too Much Background Light
Reduce the background light on the target area.
202
Laser Beam Interrupted
Remove the obstacle and repeat the measurement.
203
Insufficient Power
Replace the batteries.
301
Temperature Too High
Allow the device to cool down to a temperature within
the specified
Operating Temperature Range
.
302
Temperature Too Low
Allow the device to warm up to a temperature within
the specified
Operating Temperature Range
.
401
Hardware Error
Switch the device on/off several times. If the error still occurs,
return the defective device to the Service Center or distributor.
Refer to the
Warranty
.
402
Unknown Error
Contact the Service Center or distributor. Refer to the
Warranty
.
Содержание DW099E
Страница 2: ...C 1 2 E DW099E 2 Figures A 4 DW099E 6 21ft 6 17ft 1 2 6 17ft 4 3 6 21ft B 1 2 5 2 D AAA 6 1 3 7 5 6 ...
Страница 3: ...2 1 3 F G H ...
Страница 107: ...Notes ...
Страница 108: ... 2017 DeWalt Industrial Tool Co DEWALT Europe DEWALT D 65510 Idstein Germany 65509 Made in China 097395 Rev A July 2017 ...