background image

6

Cleaning

Exterior plastic parts may be cleaned with a damp cloth. Although these parts are 

solvent resistant, NEVER use solvents. Use a soft,  dry cloth to remove moisture from 

the tool before storage. 

FIG. 6

B

STEP 1

A

STEP 3

-90

˚

90

˚

STEP 4

STEP 5 

STEP 2

STEP 3

Field Calibration Check

CHECKING ACCURACY – HORIZONTAL BEAM, SCAN DIRECTION (FIG. 6)

Checking the horizontal scan calibration of the laser requires two walls 30' (9 m) 

apart. It is important to conduct a calibration check using a distance no shorter than 

the distance of the applications for which the tool will be used.

  1. Attach the laser to a wall using its pivot bracket, with the laser facing straight 

ahead toward the opposing wall (0 degree position). 

  2. Turn on the laser’s horizontal beam and mark the beam position on the opposing 

wall directly across from the laser. Always mark the center of the beam’s 

thickness.

  3. Pivot the laser to the extreme left (-90 degree position) and mark the beam 

position on the opposing wall.

  4. Pivot the laser to the extreme right (+90 degree position) and mark the beam 

position on the opposing wall.

  5. Measure the vertical distance between the lowest mark (A) and the highest mark 

(B). If the measurement is greater than the values shown below, the laser must 

be serviced at an authorized service center.

 

Distance  

Allowable Distance 

 

Between Walls 

Between Marks

 

9.0 m (30') 

3.0 mm (1/8")

 

12.0 m (40') 

4.0 mm (5/32")

 

15.0 m (50') 

5.0 mm (7/32")

CHECKING ACCURACY – HORIZONTAL BEAM, PITCH DIRECTION (FIG. 7)

Checking the horizontal pitch calibration of the laser requires a single wall at least 9 m 

(30') long. It is important to conduct a calibration check using a distance no shorter 

than the distance of the applications for which the tool will be used.
  1. Attach the laser to one end of a wall using its pivot bracket.
  2. Turn on the laser’s horizontal beam and pivot the laser toward the opposite end 

of the wall and approximately parallel to the adjacent wall.

  3. Mark the center of the beam at two locations (C, D) at least 30' (9m) apart.
  4. Reposition the laser to the opposite end of the wall.
  5. Turn on the laser’s horizontal beam and pivot the laser back toward the first end 

of the wall and approximately parallel to the adjacent wall.

Содержание DW089-XE

Страница 1: ...DW089 XE 3 BEAM LINE LASER INSTRUCTION MANUAL ...

Страница 2: ......

Страница 3: ...es other than those specified herein may result in hazardous radiation exposure Do not operate the laser in explosive atmospheres such as in the presence of flammable liquids gases or dust Power tools create sparks which may ignite the dust or fumes Use the laser only with the specifically designated batteries Use of any other batteries may create a risk of fire Store idle laser out of reach of ch...

Страница 4: ...r convenience and safety the following labels are on your laser WARNING TO REDUCE THE RISK OF INJURY USER MUST READ INSTRUCTION MANUAL USE AA SIZE BATTERIES WARNING LASER RADIATION DO NOT STARE INTO BEAM CLASS 2 LASER PRODUCT AVOID EXPOSURE LASER RADIATION IS EMITTED FROM THESE APERTURES FIG 1 LASER INFORMATION The DW089 XE 3 Beam Line Laser is a Class 2 laser product and complies with 21 CFR 1040...

Страница 5: ...situations Dress properly Do not wear loose clothing or jewelry Keep your hair clothing and gloves away from moving parts Loose clothes jewelry or long hair can be caught in moving parts POWER TOOL USE AND CARE Do not use the power tool if the switch does not turn it on and off Any power tool that cannot be controlled with the switch is dangerous and must be repaired Store idle power tools out of ...

Страница 6: ... accuracy often while working See Field Calibration Check If the laser has been dropped check to make sure your laser is still calibrated See Field Calibration Check LOW BATTERY INDICATION The DW089 XE laser is equipped with a red indicator light B as shown in Figure 2 The red indicator light is located to the left of the on off buttons C D E A flashing red indicator light indicates that the batte...

Страница 7: ...ceiling installation At each end of the wall mount is a screw hole L allowing the wall mount to be attached to any surface with a nail or screw Once the wall mount is secured its steel plate provides a surface to which the magnetic pivot bracket F can be attached The position of the laser can then be fine tuned by sliding the magnetic pivot bracket up or down on the wall mount H FIG 5 F K J L FIG ...

Страница 8: ...er to the extreme right 90 degree position and mark the beam position on the opposing wall 5 Measure the vertical distance between the lowest mark A and the highest mark B If the measurement is greater than the values shown below the laser must be serviced at an authorized service center Distance Allowable Distance Between Walls Between Marks 9 0 m 30 3 0 mm 1 8 12 0 m 40 4 0 mm 5 32 15 0 m 50 5 0...

Страница 9: ...ark C 8 Measure the distance between these two marks C E If the measurement is greater than the values shown below the laser must be serviced at an authorized service center Distance Allowable Distance Between Walls Between Marks 9 0 m 30 6 0 mm 1 4 12 0 m 40 8 0 mm 5 16 15 0 m 50 10 0 mm 13 32 FIG 7 C D D C E 9 m 30 STEP 1 2 STEP 3 STEPS 4 5 STEP 6 STEP 7 STEP 8 STEP 3 ...

Страница 10: ...ble ideally 9 m 30 with one person on the floor positioning the laser and another person near a ceiling to mark the position of the beam It is important to conduct a calibration check using a distance no shorter than the distance of the applications for which the tool will be used 1 Place the laser on the floor and turn on both vertical beams 2 Mark the position where the beams cross on the floor ...

Страница 11: ... laser to mark B and turn on both vertical beams 4 Position the beam crossing precisely at mark B with the forward beam aligned with mark C 5 Mark a location D along the side vertical beam at least 5 m 18 away from the unit 6 Rotate the laser over mark B so that the forward vertical beam now passes through mark D 7 Mark the location E where the side vertical beam passes by mark A 8 Measure the dis...

Страница 12: ...otionless surface the laser will continue to try to find level If the beam will not stop moving try placing the laser on a more stable surface Also try to make sure that the surface is relatively flat so that the laser is stable Repairs NOTE Disassembling the laser level will void all warranties on the product To assure product SAFETY and RELIABILITY repairs maintenance and adjustment including br...

Страница 13: ...ies Only use DEWALT accessories specified for use with this product Follow the directions included with the accessory Recommended accessories for use with your tool are available at extra cost from your local service center If you need any assistance in locating any accessory please contact Stanley Black Decker 82 Taryn Drive Epping VIC 3076 Australia or call 1800 444 224 or NZ 0800 339 258 ...

Страница 14: ......

Страница 15: ......

Страница 16: ... dewalt com au www dewalt com nz SEP11 Part No N135410 DW089 XE Copyright 2011 DEWALT The following are trademarks for one or more DEWALT power tools the yellow and black color scheme the D shaped air intake grill the array of pyramids on the handgrip the kit box configuration and the array of lozenge shaped humps on the surface of the tool ...

Отзывы: