28
English
CoDE poSSIBlE CauSE
poSSIBlE SolutIon
7
Defective capacitor
Contact a D
e
WALT factory service center or a D
e
WALT authorized
service center.
8
Faulty power cord
Repair or replace cord
9
GFCI switch breaker tripped
Depress and reset
10
Generator overloaded
Reduce load
11
Faulty cords or equipment
Check for damaged, bare or frayed wires on equipment. Replace.
12
Insufficient ventilation
Move to adequate supply of fresh air
13
Faulty solenoid
Contact a D
e
WALT factory service center or a D
e
WALT authorized
service center.
14
Faulty idle control switch
Contact a D
e
WALT factory service center or a D
e
WALT authorized
service center.
15
Faulty windings in stator
Contact a D
e
WALT factory service center or a D
e
WALT authorized
service center.
16
Faulty circuit board
Contact a D
e
WALT factory service center or a D
e
WALT authorized
service center.
17
Faulty wire harness
Contact a D
e
WALT factory service center or a D
e
WALT authorized
service center.
18
Voltage selector in the 120V position
Place the voltage selector to the 240V position when using a tool
that requires 240V.