DeVilbiss MSV-531-28FF Скачать руководство пользователя страница 3

SB-2-243-F     Page 3

Maximum air pressure required to
assure compliance of 10 PSI Max.
Cap Pressure - this reading must be
taken at the spray gun handle inlet
fitting.

Figure 1  Baffle

Air cap number located on face of
cap - cap number must correspond
with baffle number to assure 10 PSI
cap pressure.

To prevent damage to the fluid tip
(3) or fluid needle (30), be sure to
either 1) pull the trigger and hold
while loosening or tightening the
fluid tip or 2) remove fluid needle
adjusting screw (34) to relieve
spring pressure against needle
collar.

Note

When replacing the fluid tip or
fluid needle, replace both at the
same time.  Using worn parts can
cause fluid leakage.  Lapped sets
are available for most pressure
feed combinations.  See Chart 2.
Also, replace the needle packing
(22) at this time.  Lightly lubricate
the threads of the fluid tip before
reassembling.  Torque to 20-25 ft.
lbs. Do not overtighten the fluid
tip.

If the air cap is changed, the 

baffle must

also be changed.

  Use of incorrect baffle

and cap set will result in substandard
performance and or improper air cap
pressures. See Chart 1 for ordering infor-
mation.

Never completely immerse in solvent as
this is detrimental to the lubricants and
packings.

FLUID INLET GASKET (7) REPLACEMENT
INSTRUCTIONS

1. Remove fluid inlet adapter with appro-

priate wrench.

2 . Clean Loctite from gun body inlet threads

and seal area.

3 . Place gasket (7) squarely onto the fluid

inlet adapter and push it down until it is
flat against the boss.

4 . Place a couple of drops of thread sealant

(i.e. Loctite 242, med, strength, Blue or
equal) on threads before installing fluid
inlet adapter.

5 . Torque fluid inlet adapter 25-30 ft. lbs.

and tighten locknut.

AIR CAP & BAFFLE COMBINATIONS

 No.Stamped on Parts

      CFM @ Cap Pressure

Air Cap

Ref. No. 2

Ref. No. 6

Part No.

Baffle

Air Cap

Baffle

2 PSI

4 PSI

6 PSI

8 PSI

10 PSI

33A

33-50

JGHV-101-33A

JGHV-450-33-50

8.25

11.75

14.5

16.75

18.75

46MP

46-50

JGHV-101-46MP

JGHV-450-46-50

8.5

13.0

16.5

19.75

22.5

83MP

83-65

JGHV-101-83MP

JGHV-450-83-65

10.0

15.5

19.5

23.0

26.0

Set

CHART 1

FLUID TIPS AND NEEDLES

If this is No. on

Ref. No. (3)*

Ref. No. (30)

Matched Tip

Tip, Order

Fld. Tip & Gasket

Fluid Needle

& Needle Set

400 Gr. Stainless Steel Tip/303 Stainless Steel Needle (Standard)

AV-2115-FF (.055")

JGA-4040-FF

AV-2115-FX (.042")

JGA-4040-FX

AV-2120-FF (.055")**

JGA-4045-FF

AV-2120-FX (.042")**

JGA-4045-FX

AV-2120-D  (.086")***

JGA-4045-D

AV-2120-E  (.070")***

JGA-4045-E

303 Grade Stainless Steel w/U.H.M.W. Poly. Needle Seat (Optional)

AV-4915-D (.086")

JGA-4056-D

AV-4915-E (.070")

JGA-4056-E

AV-4915-FF (.055")

JGA-4056-FF

AV-4915-FX (.042")

JGA-4056-FX

AV-4920-D (.086)***

JGA-4051-D

AV-4920-E (.070)***

JGA-4051-E

AV-4920-FF (.055)**

JGA-4051-FF

AV-4920-FX (.042)**

JGA-4051-FX

    * Do not use AV-1 gasket with this spray gun.
  ** For use with 46MP air cap.
*** For use with 83MP air cap.

CHART 2

50

28

Содержание MSV-531-28FF

Страница 1: ...eedles and can be used with waterborne materials or more corrosive coatings 6 0 pH or above Thesegunmodelswillproduceapproximately 10psicappressureatthecorrespondinggun inlet pressure as measured at the gun inlet Air cap test kits see Accessories should be used to insure 10 psi air cap pressure is not exceeded Note This gun may be used with chlori nated solvents but see additional warnings on page...

Страница 2: ...ance of the equipment in accordance with the requirements of NFPA 33 Chapter 15 Users must comply with all local national codes of practice and insurance company requirements governing ventilation fire precautions operation maintenance and housekeeping These are OSHA Sections 1910 94 and 1910 107 and NFPA 33 Cumulative Trauma Use of hand tools may cause cumulative Pain tingling or numbness in the ...

Страница 3: ...pter with appro priate wrench 2 CleanLoctitefromgunbodyinletthreads and seal area 3 Place gasket 7 squarely onto the fluid inlet adapter and push it down until it is flat against the boss 4 Placeacoupleofdropsofthreadsealant i e Loctite 242 med strength Blue or equal on threads before installing fluid inletadapter 5 Torque fluid inlet adapter 25 30 ft lbs and tighten locknut AIR CAP BAFFLE COMBINA...

Страница 4: ...g Valve Optional 1 26 MSA 3 Connector 1 4 NPS 1 27 Retaining Ring 1 28 SSG 8069 K25 O Ring Kit Kit of 25 Viton 1 29 JGA 497 1 Air Valve Assembly Horn 1 30 See Chart 2 Fluid Needle 1 31 Gun Body Bushing 1 32 MBD 19 K10 6 Spring Kit of 10 1 MSA 4 K10 4 Spring Kit of 10 optional 1 33 Spring Pad included with 32 1 34 JGS 16 Fluid Needle Adjusting Screw 1 35 JGA 4041 Bushing Spring Knob Kit 1 Thesepart...

Страница 5: ...rom work surface Adjust to proper distance Improper stroking arching gun motion Too fast Move at moderate pace parallel to work surface Dry spray Air pressure too high Decrease air pressure Gun tip too far from work surface Adjust to proper distance Gun motion too fast Slow down Gun out of adjustment Adjust Fluid leaking from Packing nut loose Tighten do not bind needle packing nut Packing worn or...

Страница 6: ... 8 Cleaning Brushes Thesebrushesarehelp ful in cleaning threads and recesses of gun body Allows air adjustment at the gun Replaces JGA 132 plug Contains all necessary tip hose and nut sizes used on or with gun KK 5033 28 for JGHV 101 28 KK 5033 33A for JGHV 101 33A KK 5033 46MP for JGHV 101 46MP KK 5033 83MP for JGHV 101 83MP Air Cap Test Kit UHMW Polyethylene Needle Seat 300 S S ACCESSORIES HD 50...

Отзывы: