SUITABILITY FOR USE
It is the duty of the employer to determine such
suitability and in so doing the following factors
should be considered bearing in mind that the
circumstances of use determine the level of
protection provided.
1)
The respirator must not be used in
atmospheres immediately dangerous to life or
health; i.e those atmospheres from which it
would not be possible to escape without risk to
life or health. Such atmospheres include those
deficient in oxygen.
2)
The respirator must not be used in
atmosphere where the concentration of
contaminant may exceed the allowable
exposure limit and it should be noted that at
exceptionally high levels of physical work the
peak inhalation may exceed the constant flow
of supplied air. (See Specification)
3)
The wearer must be able to adjust and fit
the respirator correctly. The wearer must be
trained in the correct wearing and operation of
the respirator and understand the limitations of
use.
4)
The employer should ensure that the
respirator, which is intended for light duty
service, is suitable and that the appropriate
model is selected and that the trailing supply
hose will not present a hazard to the wearer or
others in the vicinity. Refer to - HSG 53. The
selection use and maintenance of respiratory
protective equipment (HSE Guide).
5)
The employer must provide a suitable
management system, to ensure that the
respirator is maintained in accordance with the
manufacturers instructions. Refer to - BS4275:
1997 Guide to implementing an effective
respiratory protective device programme.
SPECIFICATION
Protection- Assigned Protection Factor
APF=40
Carbon Filter Life = 1000 HRS.
NOTE CARBON FILTER HAS A LIMITED
SHELF LIFE.
Supply pressure - 3.8 bar (55 lbf/in²) At hose
supply connection (See Fig 1) max 7 bar (100
lbf/in²).
Supply hose - Only to be used with Devilbiss
original hose. The manufacturers flow rate is
recommended at a minimum of 140 litres/min
(4.9 SCFM) to the mask. See parts list for
recommended supply hose.
The
MPV-623
Air Fed Vizor Outfit, comprises of:
MPV-526:
Vizor Assembly with ratchet
headband, detachable vizor covers neck cover,
disposable hood, stowage bag, 2 face cassettes
and a hose to connect to MPV-518 waistbelt
assembly.
MPV-518
: Waistbelt Assembly: An adjustable
nylon belt with quick fit buckle. Disposable
carbon odour removal filter and pre-set regulator
in a moulded housing which is moveable on the
belt.
MPV-456
Rubber air hose (1.2 M) with quick
detachable fittings to connect spray gun.