2
© 2012 Finishing Brands UK Ltd.
Safety Warnings
Static Electricity can be generated by air passing though hoses. To prevent such a
risk, earth continuity to the equipment and the object being sprayed should be
maintained. Use conductive hoses and recommended to attach an earth clamp to the
stand upright. Check earth continuity with an ohmmeter, Should be less than 1 MΩ.
Never exceed the max. recommended safe working pressure for the equipment.
Never aim the Dryer at anybody. It is recommended that eye protection is worn when
using this equipment.
The A-weighted sound level of this product may exceed 85 dB (A) depending on the
pressure/airflow being used. Details of actual noise levels are available on request. It
is recommended that ear protection is worn at all times when using this equipment.
Assembly
1. Fit 4 legs to base (3). Fit lower
stand upright into base and
tighten with thumbscrew. Fit
upper stand upright and tighten
with thumbscrew.
2. Fit thumbscrews to arms (6) and
slide both arms over upright.
Secure with thumbscrew to
required height.
3. Assemble clamp assembly 5A
and 5B as per the diagrams on
P3.
4. Slide clamp assemblies over the
arms (6) and secure with
thumbscrew.
5. Attach hose (7) to the 2 clamp
assemblies.
6. Insert the 2 dryers into the 2
QD’s.
7. Make sure the dryer ball valves
are turned off, then attach the air
supply hose to clamp 5A
8. The Air supply should be filtered,
dry and free from oil (as you
would supply to the spraygun).
The DeVilbiss range of DVFR
Filter/Regulators
are
recommended for this.
Operation
1. Turn the Dryer Ball Valves to the
off position.
2. Turn on air supply. Turn on the
Dryer Ball Valves until the
required airflow is achieved. If
more air is required, increase the
pressure at the regulator.
Moving the stand
Grasp the stand and not the dryer
gun handles. This will prevent
accidentally disengaging the quick-
disconnect if the system is
pressurised.
Installation and Operation