SERVICE CHECK

 

 

 

 

problem 

Cause 

Correction 

Will not spray. 

No pressure to gun. 

 

Piston stops moving. 

Check air and material lines. 

 

Check CYL air pressure. 

Improper spray pattern. 

 

A.   

Gun not adjusted properly.   

A, B.    Material build up on the air cap (3)or fluid 

tip (4). 

A.   

Re-adjust. See “Operation Section”. 

A, B.  Clean the air cap or fluid tip.   

See “Preventive Maintenance”. 

Note 

To determine where the material build up is, rotate the air cap 180°and test spray. If the pattern 

stays in the same position, the condition is caused by material build up on the fluid tip. If the pattern 

changes with air cap movement, the buildup is in the air cap. 
C, D.    Wrong material or material too thick. 

Insufficient material or atomizing air 

pressure too high. 

C, D  Adjust material pressure or thin material. 

Increase material or reduce atomizing 

air pressure. 

Jerky or fluttering spray 

 

 

 

 

 

 

1. Insufficient material in the tank or an obstruction 

in the line. 

2. Gun material passage plugged. 

3. Worn Needle Seal Kit (7). 

4. Loose or damaged fluid tip. 

1. Fill tank or clear obstruction. 

 

2. Clean. 

3. Replace. 

4. Tighten or replace. 

Air leaking from 

Ratchet Assy. (18). 

1. Damaged or worn Piston Cup (12). 

2. Damaged cylinder of Gun Body. 

1. Replace. 

2. Replace. 

Dripping from Fluid Tip.  1. Worn or damaged Fluid Tip (4) or Needle (4). 

2. Needle Spring (14) damaged or deformed. 

1. Replace. 

2. Replace. 

Air or fluid leaking from 

Gun Body. 

Damaged or worn Needle Seal Kit (7) 

Replace. 

 

ACCESSORIES

 

 

Part No.

 

Description

 

SSL-10 

Gun Lube (60m

42884-214-K5 

Cleaning Brush (Kit of 5) 

AGA-415 

Universal Clamp 

GC-100-K48 

Gun Cover (Kit of 48) 

HD-505-W 

Quick Cleaner (5

83GZ-5200 

Solvent Saver (10

 

 

 

 

 

 

 

 

 

 

 

 

2017-07-DA-300 

Normal spray pattern

 

©2017 Carlisle Fluid Technologies.

 

HP

http://www.carlisleft.co.jp

DIVISION

®D

E

VILBISS is a registered trademark of Carlisle Fluid Technologie

s.

®Jupiter is a registered trademark of CFT Ransburg Japan KK.

Ransburg Japan KK

The proper combination of fluid pressure, fan and atomization air pressure, 

and fluid tip size should result in a pattern of this shape.

 

Содержание DA-300

Страница 1: ...t No Fluid Tip Size 0 8 1 1 1 4 1 8 mm Air Cap No 305MT 307MT 345 NOTE The fluid passage is made of Stainless Steel This gun can be used with waterborne paint Chart 1 Air Cap Fluid Tip Size mm Pattern...

Страница 2: ...solvents for cleaning Those used for equipment flushing must have a flash point equal to or greater than that of the coating Those used for general cleaning must have flash points above 100 F 37 8 C...

Страница 3: ...f actual noise levels produced by the various air cap nozzle set ups are available on request Wear earplugs when using the spray gun Spraying solvent Pressured air fluid passage may be broken when cle...

Страница 4: ...Please use air regulator for setting the air pressure for the smooth movement of CYL 3 Turn Needle Adjusting Knob counter clockwise 3 5 turns from fully closed position This makes the Needle fully op...

Страница 5: ...Needle Packing Kit 7 1 Relieve all air and fluid pressure in system 2 Remove Retaining Ring 1 and Air Cap 3 3 Remove Fluid Tip 4 4 Replace Fluid Tip and Needle at the same time with the lapped set It...

Страница 6: ...ve Gasket 1 10 DA P10 K5 O Ring Kit of 5 1 11 DA 43 Air Valve Assy 1 12 DA Y20 K3 Y Packing Kit of 3 1 13 DA 9 Piston Assy 1 With DA Y20 14 DA 4993 Spring Kit 1 15 DA 46 K5 E Ring Kit of 5 1 16 3 16BA...

Страница 7: ...struction in the line 2 Gun material passage plugged 3 Worn Needle Seal Kit 7 4 Loose or damaged fluid tip 1 Fill tank or clear obstruction 2 Clean 3 Replace 4 Tighten or replace Air leaking from Ratc...

Отзывы: