background image

Deviation Firmware

for Devo7e/10

 User’s Manual

Version 3.0

Содержание Devo10

Страница 1: ...Deviation Firmware for Devo7e 10 User s Manual Version 3 0...

Страница 2: ...Settings 11 Main Page Configuration Standard Advanced GUI 12 Preview 12 Trim Positions 12 Boxes 12 Switch Display 12 Quick page Selection 12 Mixer Advanced GUI 13 Simple Template 14 Expo Dual Rate Te...

Страница 3: ...Advanced GUI 27 Telemetry Configuration Page Standard Advanced GUI 28 Standard GUI 29 Servo Reverse Standard GUI 29 Sub trim Adjustment Standard GUI 29 Servo Travel Adjust Standard GUI 30 Swash Confi...

Страница 4: ...rough text files which the firmware or user can read and write It is easy to know exactly what is configured as well as to modify the configuration either through the transmitter or with a text editor...

Страница 5: ...tool You will need the Devention DfuSe USB Upgrade Tool from Walkera http www walkera com en upload upgrade 2013 2 26 rar Do NOT attempt to use the DfuSe tool from STMicroelectronics It is recommende...

Страница 6: ...strongly recommended to back up the models directory from the transmitter as well as the tx ini file to ensure you don t lose any model or transmitter configuration Next unzip the deviation fs devoXX...

Страница 7: ...ew files It is therefore necessary to have a modelxx ini for each model regardless of whether it is currently in use modelico bmp All available model icons must be 96x96 pixels templates ini Configura...

Страница 8: ...e Displays These can be text boxes contacting input channel telemetry or timer data bar graphs displaying channel data or icons displaying specific states e g gear flaps Model Icon An image representi...

Страница 9: ...value selection On all menu pages UP and DN are used to navigate to the previous next item The R and L buttons are used on spin box widgets to increase or decrease the selected value In some cases ho...

Страница 10: ...al stick Aileron in mode 2 R F Right Horizontal trim z Gear x Rudder Dual Rate switch c Elevator Dual Rate switch v Aileron Dual Rate switch b Mix 0 1 2 switch n FMode 0 1 2 switch Power off Left arro...

Страница 11: ...r and Rudder on right Sticks Calibrate the range of all analog sticks and dials Buzz Settings Buzz volume Set buzzer volume Vibration Turn haptic feedback on off Batt alarm Set battery voltage at whic...

Страница 12: ...side Only 4 trims are shown and they are placed at the middle of the screen 6 Trims 6 trims are shown all placed towards the inside Boxes Boxes are used to display interesting text values There are 8...

Страница 13: ...single input an activation switch and a function curve that modifies the mixer output This is a very powerful capability but it is requires a lot of understanding to make full use of In order to simp...

Страница 14: ...ent mixer settings making it possible to test them on the transmitter Src The input source controlling this mixer Curve The function applied to the input to generate the output See the Curve section f...

Страница 15: ...ed or alternatively can have an independent curve definition Pressing the Mid Rate or Low Rate button for a given switch will toggle between linked and independent curves A Long ENT press will update...

Страница 16: ...the previous mixers Mult Multiply the value of this mixer with the previous mixers Max The output will be the greater of the current mixer vs the previous mixers Min The output will be the lesser of t...

Страница 17: ...se 0 if Switchn 1 Mn 1 else 0 if Switch0 M0 else 0 For a Max mux Cx MAX if Switchn Mn else 0 if Switchn 1 Mn 1 else 0 if Switch0 M0 else 0 For a Min mux Cx MIN if Switchn Mn else 0 if Switchn 1 Mn 1 e...

Страница 18: ...mixer and use the up down buttons to move the order of the selected mixer Note that the mixer name rep resents its position when the reorder dialog was opened If the dialog is closed and re opened al...

Страница 19: ...ve Editor is accessed by pressing a graph or by pressing the curve spin box when it is selectable Some curve types may not be edited any of the curves preceding the Expo curve and the curve box will n...

Страница 20: ...lsafe Specifies a value that the Rx should use when it loses signal from the transmitter Not all receivers support this capability Safety Specifies a switch that will override all mixers and force the...

Страница 21: ...l to a new location resetting the current model to the default all configuration is lost and loading templates see Predefined Templates Model Name Set the model s name Icon Choose the model s icon Mod...

Страница 22: ...VO protocol also supports enabling disabling the telemetry capability This option is accessed by pressing the Protocol spin box when DEVO is shown Protocol WK2801 The WK2801 protocol is used to contro...

Страница 23: ...does not prevent auto binding during power on Protocol DSM2 The DSM2 protocol is used to control many Spektrum and JR as well as other models using this protocol While the DSM2 protocol can support up...

Страница 24: ...er will attempt to auto bind with the receiver every time it is powered on If a value is set for FixedID the receiver must be bound manually one time using the Bind button after which it should stay b...

Страница 25: ...fore the first use The Frsky2way protocol also supports enabling disabling the telemetry capability This option is accessed by pressing the Protocol spin box when Frsky2way is shown Protocol Skyartec...

Страница 26: ...ed Templates The Deviation firmware supports user customizable predefined templates By Selecting Template From the Model page it is possible to select one of these options Additional templates can be...

Страница 27: ...either manually from the main screen or by an input trigger stick or switch Timers can also be optionally configured to be reset via an alternate switch only when using the Advanced GUI The permanent...

Страница 28: ...occur This page is accessed from the main menu via Model menu followed by Telemetry Telemetry Specify the telemetry input to use for alarm control This can be a temperature probe voltage probe or RPM...

Страница 29: ...ration See page 31 10 Swash Swash Setup See page 30 11 Fail safe Fail Safe configuration See page 31 12 Switch assignment Assign switch controls See page 31 13 Timers Timer configuration See page 27 1...

Страница 30: ...degree swash 3Servo 120x 120 degrees swash alternate config 3Servo 140 140 degree swash 3Servo 90 90 degrees swash Dual Rate Expo setting Standard GUI The dual rate and expo page allows configuration...

Страница 31: ...l as which channel to use for sending the gyro value Switch Assignment Standard GUI The switch assignment page enables configuring which switches to use for each capability in the standard GUI The sam...

Отзывы: