Do not place the thermostat on the inner side of
an exterior wall.

Always install the thermostat at least 50 cm from
windows and doors.

Do not place the thermostat in a way that it will be
exposed to direct sunlight.

Note: A floor sensor enables a more accurate tem-
perature control and is recommended in all floor
heating applications and mandatory under wood-
en floors to reduce the risk of over-heating the
floor.

Place the floor sensor in a conduit in an appropriate

place where it is not exposed to sunlight or draft from

door openings.

Equally distant and >2cm from two heating cables.

DEVIreg™ 132

Installation Guide 

7

Содержание devireg 132

Страница 1: ...DEVIreg 132 Electronic Thermostat Installation Guide www DEVI com...

Страница 2: ......

Страница 3: ...nstalled di rectly on the wall It is provided with a room sensor to con trol the room temperature and an additional floor sensor to limit the maximum floor temperature The thermostat has a button for...

Страница 4: ...15 kOhm at 25 C Sensing values 0 C 42 kOhm 25 C 15 kOhm 50 C 6 kOhm Hysteresis 0 2 C Ambient temperature 0 to 30 C Frost protection tempera ture 5 C Temperature range 5 35 C room temperature 20 50 C f...

Страница 5: ...ilar use EN IEC 60730 1 general EN IEC 60730 2 9 thermostat 1 2 Safety Instructions Make sure the mains supply to the thermostat is turned off before installation IMPORTANT When the thermostat is used...

Страница 6: ...nsidered as live voltage Have this in mind if the sensor must be extended Always connect the thermostat to continuous power supply Do not expose the thermostat to moisture water dust and excessive hea...

Страница 7: ...light Note A floor sensor enables a more accurate tem perature control and is recommended in all floor heating applications and mandatory under wood en floors to reduce the risk of over heating the fl...

Страница 8: ...radius of the conduit must be min 50mm Follow the steps below to mount the thermostat 1 Open the thermostat Remove the button to get access to the screw which holds the front Loosen the screw Push dow...

Страница 9: ...nnect the thermostat according to the connection diagram IP30 0T30 D132 NTC L N 1 2 3 4 Sensor Max Load 16 1 A Mains 220 240V N LOAD L LOAD The screen of the heating cable must be connected via a conn...

Страница 10: ...ht corner 5 Install the front cover and button in the reverse order of disassembly 6 Turn on the power supply 3 Settings How to change the minimum and maximum floor tem peratures 1 Lift off the adjust...

Страница 11: ...op Floor manufactures often specify the max tempera ture on the top surface of the floor usually 27 28 C By default the maximum floor temperature is set to 35 C Always use a floor sensor or a room flo...

Страница 12: ...05 8 mm HDF based laminate 800 kg m3 28 C 0 10 14 mm beech par quet 650 800 kg m3 31 C 0 13 22 mm solid oak plank 800 kg m3 32 C 0 17 Max carpet thick ness suitable for floor heating acc to EN 1307 34...

Страница 13: ...5 Disposal Instruction DEVIreg 132 Installation Guide 13...

Страница 14: ...DEVIreg 132 14 Installation Guide...

Страница 15: ...inted material Danfoss reserves the right to alter its products without notice This also applies to products already on order provided that such alterations can be made without subsequential changes b...

Страница 16: ...011 220 240V 50 60Hz 5 to 35 C Temp Limit 20 to 50 C 16A 3680W 230V IP 30 Product Documentation DK EL 7224215014 SE EL XXXXXX NO EL 5402692 FI SSTL 3531132 Designed in Denmark for Danfoss A S 5 7 0 3...

Отзывы: