User Guide
4
TS 500
2.2 Using the Setup Wizard
The Setup Wizard will give you step-by-step instructions. Below are a few tips to keep in
mind when setting up your thermostat with the Setup Wizard.
2.3 Manual Setup
2.3.1 Control Type
The
TS 500 can be set up with 4 different control types:
•
Floor:
This is the standard control type for underfloor heating. The thermostat regulates the
floor temperature rather than the air temperature. This allows for a better control, as the issues
that could arise with air sensing (opened windows, inconsistent temperature through the room)
are eliminated. The thermostat needs to be connected to a sensor probe that measures the
temperature of the floor. Note that typical setup temperature should be 27°C or more.
•
Air:
The thermostat regulates the air (room) temperature using the internal sensor.
•
Air sensor:
The thermostat regulates the air (room) temperature using an external probe. This is
an benefit when the thermostat is located in an area where the temperature is not representative
of the room temperature (near a window, a fireplace etc).
•
Air/Floor:
The thermostat regulates the air/room temperature, while keeping the floor temperature
to a maximum limit. This control type is to be used with underfloor heating with a timber finish,
as it is important to keep the floor board below a certain temperature (usually 27°C) to avoid
warping/cracking. Contact your timber supplier for specific temperature information.
How to set up the control type
Return to home
page by using
home icon .
Press (and hold) arrows to
increase and decrease values.
Cancel changes
by pressing
CANCEL.
Confirm a value
by pressing
OK.
Set up time
00 : 00
OK
Cancel
1
Touch the thermostat display to activate it, then press
Menu.
2
Press
Installation
then
Manual
Setup.
3
Press
Control
Type.
Setup
Control Type
Air Sensor
5.0º
50.0º
PID
Min.Temperature
Max. Temperature
Temperature regulation
Choose Control
Floor
Air
Air Sensor
Air / Floor
OK
Cancel
4
Select the desired control type then press
OK
to confirm.
5
To return to
the home page
press .