3. Periodical check
Field Service Ver. 1.0 Apr. 2005
10
ineo 161
ineo 210
Maintenance
3.3
Maintenance procedure (Periodical check parts)
NOTE
• The alcohol described in the cleaning procedure of Maintenance represents the
isopropyl alcohol.
3.3.1
Replacing the Separation Roller Assy and Feed Roller
1.
Slide out the Paper Feed Tray/1.
2.
Remove two screws and the mount-
ing bracket.
3.
Remove the Separation Roller Assy.
4.
Press down the Paper Lifting Plate.
5.
Snap off one C-clip from the Feed
Roller Assy.
6.
Slide the Feed Roller Assy to the
rear and pull it off the Bearing at the
front.
7.
Snap off one C-clip and remove the
Feed Roller.
4035D001AB
4035D002AA
4035D003AB
5
6
4035D004AA