Put the assembly on the top of the humidifier
(picture n°6).
x
Put a container or the optional flexible calcius col-
lecting bag on ground and empty the boiler
contents in it (s.a. picture n°7).
x
Take care : the tank gasket should be changed
whenever the boiler is maintained (s.a. picture
8). Retighten all the collar clamps.
Do not scratch, hit or use corrosive liquids on
the heating elements.
x
Uncap the water level tank and clean the 4 electro-
des (s.a. picture n°9).
Do not use any solvent to clean the water level
tank nor special glues if the tank needs being
attended but use teflon. Use a scraper on sen-
sor electrodes if needed
x
Set back the high water level tank cap. Reassem-
ble the boilder cover assembly and the boiler in the
same relative position.
x
Make sure there is still the O ring in the drain valve
boby before putting back the steam boiler (s.a. pic-
ture n°10-b).
Tighten up all the screws of the boiler top and
reconnect the steam hose.