This Quick user guide will make the installation of DB
5000 -
TCP/IP, COM & USB Connectivity
quick and easy.
Following
these
steps
will
simplify the process and
may
save you extra time and effort.
For more information about the Safety precautions and the Operating
environment recommendations please refer to the User Manual.
RDS/RBDS Radio Data Decoder with
1.
Install the unit on its operation place;
2. Connect the unit via grounding cable to the ground network of the room space where the unit is installed;
3.
Connect the
device
to the power supply network using th
e provided
power cable;
4.
Connect the antenna cable to the RF antenna input connector located on the rear panel of the device;
5.
Connect DB
5000
to the TCP/IP network usin
g a
direct network cable
.
DB5000 supports TCP/IP, COM & USB Connectivity. The "Device Manager Software" maintains each
of the connections independently. The device prevents simultaneous connections. The priority of each
connection is controlled by the device, not from the software. The connection priority in
ascending
order is
:
TCP/IP, COM and USB (The USB connection is with the highest priority).
For example, if a connection with lower priority is used any other connection with higher priority
implicates the lower priority connection will be disconnected. Once disconnected, the reconnecting must
be managed manually.
In order to avoid hardware conflicts and connection problems, install the software before connecting
the device to the computer.
1. Use the Installation file which can be found on the supplied CD or downloaded from
www.devabroadcast.com/downloads;
2. The software has an
"AutoRun"
utility and will automatically begin the installation;
3. If the
Setup Wizard
does not start automatically follow these steps:
?
Click on
"Start"
, then go to
"My Computer"
, and finally double-click on the
"CD Drive"
;
?
Find
"Software"
folder, double click on
"DB5000_Device_Manager.exe"
to launch the Wizard.
4. Accept the default recommendations and click
"Next>"
at the end of each step;
5. When asked to place an icon on the computer Desktop, click on the check the box;
6. Finally, select NOT to launch the program;
7. Close the software installation utility.
Follow these steps for the installation of the USB driver:
1. The USB driver should be added into the folder containing DB5000 program path. If you have not made
any changes during the installation process the driver must be located at:
My Computer / Local Disk
(C:) / Program Files /DB5000 Device Manager / Drivers
;
2. Connect DB5000 to the AC, then connect the front/rear-panel USB port to the computer. Instantly a
"New Hardware"
notification will appear. Start the
Wizard
, select
"No, not this time"
and then
Next>
.
Select
"Install from a list or specific location (Advanced)"
and then
Next>;
3. Verify the location of the driver and click
Next>
;
4. The
"Hardware Wizard"
will inform you when the installation is complete.
In order for the RDS/RBDS to be measured accurately the
Input Level
should be manually set to 75
kHz. Both the trim control labeled
"Input Level"
and the
LED Indicator
are placed on the rear panel of the
device.
Feed the device with mono signal corresponding to 75kHz modulation. Using a screwdriver start
setting the
"Input Level"
until the LED Indicator
"Level OK"
indicates it. The light has to be constantly
switched on while the signal needed for the calibration is fed.
USB Port Installation
STEP 5
Device Manager Software Installation
STEP 4
Connection Priority
STEP 3
RDS/MPX Input Configuration
STEP 2
Connection
STEP 1