Web interface

0x1F8D

NMT_PResPayloadList_AU16

This object holds a list of the expected PRes Payload data size in octets for each configured CN 
that is isochronously accessed, e.g. via PReq / PRes frame exchange. 

0x1F98

NMT_CycleTiming_REC

NMT_CycleTiming_REC provides node specific timing parameters, that influence the EPL cycle 
timing. All entries must be supported by a CN. On the MN, some of the entries are irrelevant. 

Содержание V3585E

Страница 1: ...ion manual EPL Router Art no V3585E Deutschmann Automation GmbH Co KG Carl Zeiss Str 8 D 65520 Bad Camberg Tel 49 0 6434 9433 0 Hotline 49 0 6434 9433 33 Fax 49 0 6434 9433 40 Internet http www deutsc...

Страница 2: ......

Страница 3: ...are 7 3 Web interface 8 3 1 Login 8 3 2 Basic General 8 3 3 Basic Routing 9 3 4 Basic Network Address Translation NAT 10 3 5 EPL Router Configuration 11 3 5 1 File layout 12 4 Setups 14 4 1 Variant 1...

Страница 4: ...Deutschmann Automation GmbH Co KG 4 Instruction manual EPL Router V 1 1 23 4 10...

Страница 5: ...used So every CN Control Node has an object dictionary which can be accessed over the SDO Service Data Object communication The Device Monitor only needs an EDS file from the linked device to access...

Страница 6: ...EPL Gateway modules Actual following modules are implemented on EPL Gateway IP Routing Router Type 1 This module is part of the EPL specification routing type 1 The configuration is taking place over...

Страница 7: ...ary and using other initialisation So it is possible to be MN or CN at the same time To select boot up behavior node ID selector has to set to 240 or 1 239 For router behavior also a special file is l...

Страница 8: ...gin Web Interface access is locked by a password which allows to protect settings from attacks of the Internet In software version V1 0 only a standard password is used 3 2 Basic General It is possibl...

Страница 9: ...es are part of the routing table which are based on the actual IP address Without this route the device has no ability to communicate over Ethernet The EPL gateway has two dif ferent interfaces One fo...

Страница 10: ...The following screen shows the settings based on EPL index 0x1D00 0x1DFF The network address translation shows a table for the translation between the EPL addresses and the generic addresses The EPL...

Страница 11: ...e IP addresses in an internal network Every request which is sent over a NAT gateway gets a new IP source address Frames which come to a network over a NAT gateway get a correct destination IP address...

Страница 12: ...subindex value Example init 0x1000 2 500 0x1006 NMT_CycleLen_U32 This object defines the communication cycle period in s This period defines the SYNC interval 0x1F81 NMT_CNAssignment_AU32 This object...

Страница 13: ...list of the expected PRes Payload data size in octets for each configured CN that is isochronously accessed e g via PReq PRes frame exchange 0x1F98 NMT_CycleTiming_REC NMT_CycleTiming_REC provides nod...

Страница 14: ...d as standard gateway DGW on every EPL device The Gateway have to be part of the cycle as isochronous or asynchronous only node For this behavior set CNAssignment_AU32 0x1F81 subindex 254 to 0x0000000...

Страница 15: ...s legacy or office network and the blue line shows the virtual extension to legacy network This node can be reached from every device outside the EPL network that is part of the router subnet If you a...

Страница 16: ...Setups Deutschmann Automation GmbH Co KG 16 Instruction manual EPL Router V 1 1 23 4 10 See the following NAT table on the gateway s web interface...

Страница 17: ...23 4 10 Instruction manual EPL Router V 1 1 17 Deutschmann Automation GmbH Co KG Setups See the following routing table on the gateway s web interface...

Страница 18: ...Firmware Update Deutschmann Automation GmbH Co KG 18 Instruction manual EPL Router V 1 1 23 4 10 5 Firmware Update For firmware updates please contact us...

Страница 19: ...IP addresses please modify generic bin for software version V1 0 Default generic IP in generic bin 172 16 48 220 Make a ftp connection like Total Commander and change the IP address with an editor Not...

Страница 20: ...eutschmann Automation GmbH Co KG 20 Instruction manual EPL Router V 1 1 23 4 10 7 Technical details Mounting DIN rail with integrated grounding Temperature range 0 C 55 C Dimension 23x100x115 BxHxD Su...

Страница 21: ...23 4 10 Instruction manual EPL Router V 1 1 21 Deutschmann Automation GmbH Co KG Technical details...

Страница 22: ...Technical details Deutschmann Automation GmbH Co KG 22 Instruction manual EPL Router V 1 1 23 4 10...

Отзывы: