24.7.12
Instruction manual LOCON 24, 48, 64, LTC, TERM 24 and TERM 6 V. 8.8
89
Deutschmann Automation GmbH & Co. KG
Technical details
16.2 Technical data LOCON 24
Characters
Basic equipment
Options
Operating Voltage
24 Volt DC
20%, max. 0,2A (switched off)
Data protection
EEPROM (at least 100 years); no battery
[] Via transfer-program on PC
Programs
64
Number of Cams
1000 cams, optionally distributable to chan-
nels and programs; cams are interchangeable
linewise
[]
[]
1500 cams, optionally distributable to chan-
nels and programs;
Angle-/time-cam
Zero-point offset
Programmable over the entire range
Position recording
Absolute encoder Gray-code parallel 24 V; to
13 Bit (2 ... 8192), Gray-code 360, 720, 1000,
3600 and 7200 inf./rev.
Programmable reverse direction of rotation
[]
[]
[]
Incremental encoder, counting area up to
16384, optional A/B-or count-/direction-signal
SSI-encoder up to 13 Bit (2 ... 16384)
Encoder monitoring function
MT: Inc. counting area up to 16777216
SSI up to 24 Bit
Outputs
48, short-circuit proof, 24 Volt/0,3A,
(max. 1A/8 Outputs), plus-switching
[]
[]
[]
Floating Run-control
Lockable outputs
Output change - dependent on the direction
of rotation
Inputs
13 inputs for encoder signals
6 inputs for channel selection
1 input program change
1 input program release
[] 16 inputs for logic-connection (cycle time
increases by 300µs + 10µs per connection
Idle time compensa-
tion (ITC)
0 ... 999ms blockwise
[]
[]
[]
0 ... 999ms blockwise or bitwise
Separate switch-on and switch-off delay at
blockwise ITC
Highly-dynamical ITC
Cycle time
75µs (without ITC)
150µs (with blockwise ITC)
300µs (with bitwise ITC)
350µs (with separate switch-on/switch-off ITC)
[] At MT: 950µs + 12µs/cam
Programming
Via integrated operating panel with LCD-dis-
play with LED-background lighting
Menu multilingual
Teach-In
[]
[]
[]
With external control unit TERM 6, 24, 32
Offline/online via PC
Via open communication profile
Display
Encoder position and speed (7 section dis-
play)
Output display via LED
Speed display scalable
Gear factor
Interface
RS485 DICNET-network for up to 16 axis
RS232 (switchable)
Connection
Via screw-plug-connector
Installation
Frontplate installation
[] PM-version (without operation front) for DIN-
rail mounting
Type of protection
IP54
[] IP65
Dimensions
144 x 144 x 44 mm(WxHxD)
[] 168 x 168 x 44 mm (WxHxD)
Switchgear opening
138 x 138 mm (WxH) (DIN 43700)
[] 138 x 138 mm (WxH) (DIN 43700)