Offset-table
Deutschmann Automation GmbH & Co. KG
14
Instruction manual LOCON 100 / 200 and ROTARNOCK 80 / 100 with fieldbus connection V. 1.0
22.1.08
6.11
LOGIC-function: LOGIC
Structure
Value
Function
Length
ProgNo
from 0 to MAX_PROG
BYTE
DestNo
from 1 to 16
0 deletes complete logic function BYTE
DestType
0 = hardware output
1 = flag
2 = hardware output inverted
3 = flag inverted
BYTE
OpNo1
1 - 32
BYTE
OpType1
0 = internal cam control output
1 = input: hard-/software
2 = flag
3 = SR (shift register)
4 = PB (only LOCON 200)
input
BYTE
LogicFct1-2
0 = none
1 = or
2 = and
3 = or not
4 = and not
BYTE
OpNo2
1 - 32
BYTE
OpType2
see OpType1
BYTE
LogicFct2-3
see LogicFct1-2
BYTE
OpNo3
1 - 32
BYTE
OpType3
see OpType1
BYTE
LogicFct3-4
see LogicFct1-2
BYTE
OpNo4
1 - 32
BYTE
OpType4
see OpType1
BYTE
OutputDelay
ms
at present max. 255
WORD
OutputTrigger
0 = leading edge
1 = trailing edge
BYTE
Module number
(only LOCON 200)
0 basis
x I/O-module number
BYTE
6.12
GSD-modules for Profibus cam control
GSD-file
Module
Cam control
R80
“S7DB(universal)“
ROTARNOCK 80
R100
“S7DB(universal)“
ROTARNOCK 100
R100
“S7DB(uni.)+logic16“
ROTARNOCK 100 with logic
L100
“S7DB(universal)“
LOCON 100
L100
“S7DB(uni.)+logic8“
LOCON 100 with 8 logic inputs
L100
“S7DB(uni.)+logic16“
LOCON 100 with 16 logic inputs
L200
“L200-Basis(S7-mode)“
LOCON 200 (incl. logic)
L200 IO8
“L200-IO8“
LOCON 200-IO8-expansion