background image

AL-436-00-902 EnoSense People Counter 
 

 
Product manual 

Page 18 of 18 

 

© DEUTA Controls GmbH

 

Paffrather Str. 140, 51465 Bergisch Gladbach

 

Tel.:+49 2202 285 57- 61 

01.12.2021 

Hauptstraße 76, 32479 Hille 

 

 

Tel: +49 5734 51466 - 0 

Technical data might change 

 

[email protected]

;  

www.deuta-controls.dnet

 

Fax:+49 5734 51466 - 28 

List of tables 

Table 1: Technical data / communication .............................................................................. 8

 

Table 2: Technical data / PIR sensor ..................................................................................... 8

 

Table 3: Technical data / user interfaces ............................................................................... 8

 

Table 4: Technical data  / housing ......................................................................................... 8

 

Table 5: Technical data / power supply ................................................................................. 8

 

Table 6: Technical data / environmental conditions ............................................................... 9

 

Table 7: Technical data / dimensions and weight .................................................................. 9

 

Table 8: Technical data / tests and approvals ........................................................................ 9

 

Table 9: Technical data / standards and guidelines ............................................................... 9

 

Table 10: Technical data / EnOcean EEP for TX ..................................................................11

 

Table 11: EnOcean transmit data .........................................................................................11

 

 

 

 
 

 

 

 

 

 
 

13 Revision history 

Version 

Author 

Reviewer 

Date 

Major changes 

1.00 

Lehzen 

Pohl 

15.06.2021 

Initial release 

1.01 

Lehzen 

Pohl 

19.11.2021 

Adopted data transmission 

to optimize power 

consumption 

1.02 

Lehzen 

Pohl 

01.12.2021 

Removed FCC §15.101 

statement in 10; 

Added/changed functional 
description 

 

 

------------ End of document ----------- 

Содержание enocean EnoSense AL-436-00-902

Страница 1: ...tstra e 76 32479 Hille Tel 49 5734 51466 0 Technical data might change info deuta controls de www deuta controls net Fax 49 5734 51466 28 AL 436 00 902 EnoSense People Counter EnOcean Sensor for peopl...

Страница 2: ...rovisions is prohibited Reproduction translation electronic and phototechnical filing archiving e g photocopying as well as any amendments require the written consent of DEUTA Controls GmbH Bergisch G...

Страница 3: ...tended use 7 4 4 Observe statutory provisions for operating frequency range 7 4 5 Non conduction mounting surface 7 5 Technical data 8 5 1 Communication EnOcean wireless interface 8 5 2 Sensor Motion...

Страница 4: ...adbach Tel 49 2202 285 57 61 01 12 2021 Hauptstra e 76 32479 Hille Tel 49 5734 51466 0 Technical data might change info deuta controls de www deuta controls dnet Fax 49 5734 51466 28 9 Device labels 1...

Страница 5: ...umentation This documentation is only applicable to the product AL 436 00 902 EnoSense People Counter and is only applicable starting from products with FW HW Version 1 0 1 1 The device must only be i...

Страница 6: ...00 902 EnoSense People Counter offers the possibility to recognize passing people in both directions and to send the current count value via radio EnOcean The sensor electronics which are built into...

Страница 7: ...ust not be used in any relation with equipment that supports directly or indirectly human health or life or with applications that can result in danger for people animals or real value 4 4 Observe sta...

Страница 8: ...1 Transmit receive center frequency 902 875 MHz Maximum transmission power 99 dB V m Table 1 Technical data communication 5 2 Sensor Motion PIR Detection angle 120 degrees Detection range 0 5 2 m Tabl...

Страница 9: ...15 40 C Storage temp 20 70 C Rel humidity 0 99 rel humidity non condensing Protection class IP20 Table 6 Technical data environmental conditions 5 7 Dimensions and weight Weight 87 g Dimensions 36 x...

Страница 10: ...PIR technology Depending on the direction counter will be incremented or decremented by one for each event 6 2 Send learn telegram To connect the EnoSense People Counter to any building automation sy...

Страница 11: ...ot used 0 24 8 DB0 7 DB0 0 Counter value CNT Counter value 0 255 1 Table 11 EnOcean transmit data 6 3 2 People counting data transmission rules Operational description of People counting data transmis...

Страница 12: ...ange info deuta controls de www deuta controls dnet Fax 49 5734 51466 28 If more people are counted in the following time period the People Counter will send the new accumulated counter value after 65...

Страница 13: ...have to take care of electrostatic discharge Otherwise electronics can be damaged In case of discharged batteries they can be replaced with two new AA batteries 1 5 V You have to push the housing wit...

Страница 14: ...ght change info deuta controls de www deuta controls dnet Fax 49 5734 51466 28 9 Device labels The following labels are placed on the bottom side of the EnoSense People Counter Label 1 FCC ID 2AZTH AL...

Страница 15: ...dnet Fax 49 5734 51466 28 10 FCC United States Regulatory Statement This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause...

Страница 16: ...18 DEUTA Controls GmbH Paffrather Str 140 51465 Bergisch Gladbach Tel 49 2202 285 57 61 01 12 2021 Hauptstra e 76 32479 Hille Tel 49 5734 51466 0 Technical data might change info deuta controls de www...

Страница 17: ...ternal Dimensions 36 x 37 x 80 mm EnOcean 902 MHz FCC Housing PC beige similar to RAL 9010 pure white incl adhesive pad AL 436 00 902 EnOcean sensor EnoSense People Counter black FCC 12467 Sensor EnOc...

Страница 18: ...4 Technical data housing 8 Table 5 Technical data power supply 8 Table 6 Technical data environmental conditions 9 Table 7 Technical data dimensions and weight 9 Table 8 Technical data tests and appro...

Отзывы: