Rev. 10 - 23/05/2022  LG

DEUS

 -  

CT1 24

 

Display

B

A

ELECTROMECHANICAL GEAR MOTOR FOR SLIDING GATES 
WITH CONTROL UNIT 

 

INSTRUCTIONS AND WARNINGS FOR INSTALLATION, USE AND MAINTENANCE

GB

CONTROL UNIT  TOUCH 
WITH DISPLAY

DEUS 4HP  for gates Max 400Kg
DEUS 6HP  for gates Max 600Kg 
DEUS 4HS  for gates Max 400Kg

Содержание CT1 24

Страница 1: ...ELECTROMECHANICAL GEAR MOTOR FOR SLIDING GATES WITH CONTROL UNIT INSTRUCTIONS AND WARNINGS FOR INSTALLATION USE AND MAINTENANCE GB CONTROLUNIT TOUCH WITHDISPLAY DEUS 4HP for gates Max 400Kg DEUS 6HP for gates Max 600Kg DEUS 4HS for gates Max 400Kg ...

Страница 2: ...e is damaged it must be replaced by the manufacturer or its technical assistance service or in any case by a person with a similar qualifica on in order to prevent any risk WARNING Automa on for sliding gates The gate can operate unexpectedly therefore do not allow anyone or anything to stop in the gate movement area WARNING Important safety instruc ons Follow all instruc ons as incorrect installa...

Страница 3: ...al opening remote learning 5 2 Par al Pedestrian opening remote learning 5 3 Remote control learning on Relay contact 5 4 Remote control learning via radio 5 5 Remove one transmi er all transmi ers 6 SETTINGS P 15 7 VISUALIZATION OF THE INPUT STATUS VIA DISPLAY P 17 8 CONNECTION WITH EMERGENCY BATTERIES P 18 9 GENERAL INFORMATION P 19 9 1 Manufacturer s data 9 2 Intended use 10 SAFETY INSTRUCTIONS...

Страница 4: ...rovide the space necessary for maintenance and manual release operations Check the overall dimensions by referring to the image below Type Without limit switch Double magnetic encoder 24V irreversible mechanical gearmotor for sliding gates Supply voltage Line Power 230Vac Line current 230Vac Engine type Maximum motor power Maximum motor current Thrust Maximum starting torque Maximum speed Intermit...

Страница 5: ... space necessary to carry out maintenance and manual release opera ons 2 2 Installa on and fixing of the anchoring plate a Respect the dimensions in the image b In order to place the anchor plate correctly respect its orienta on LEFT RIGHT as shown in the image c Respect the height dimensions as indicated in the image with pinion Z16 d Posi on the pipes of the electric cables leaving them protrudi...

Страница 6: ... to the gate Fix the gearmotor defini vely by locking the two M10 bolts and rela ve washers with a special wrench 2 4 Rack assembly 2 3 Installa on and fixing of the gearmotor Release the gearmotor properly fix the rack to the gate with the supplied screws Leave 1mm gap between the pinion and the rack teeth Verify that the complete movement occurs without obstacles and impediments Check the presen...

Страница 7: ...imbalance This command allows you to release the gearmotor transmission and move the leaf manually It can be used in the event of a power failure or system failure Manual release takes place using a key which must be kept in a safe place a slide the lock protec on to the le b insert the key into the lock and turn it 90 an clockwise c rotate the lever 90 d the gearmotor is now unlocked ATTENTION ...

Страница 8: ...a polychloroprene sheath All cables must be stripped to the minimum necessary maximum 6 mm as close as possible to the connec on terminals to avoid accidental contact with live parts if the cable comes off from the terminal Do not pre n the cables that are to be screwed to the terminals Use the power cord fastener a Remove the cover from the gearmotor b Open the holes provided in the cable gland m...

Страница 9: ...he control unit motor encoder and transformer are already made by the manufacturer and must not be modified in any way ATTENTION To facilitate connec on to the control unit remove the connector with the help of a screwdriver Once the wiring is complete insert it in the correct posi on With clamps block the wires in the slots adjacent to the connector Use cables of suitable sec on and type ...

Страница 10: ...NANCE ANTENNA Antenna input Func on Encoder A B OPENING SAFETY NC input for opening safety devices During the gate opening cycle the interven on of the safety determines a short inversion FLASHING 24 Vdc 5 W max output for connec ng the flashing light STEP BY STEP NO input Determines the gate movement according to the following cycles SEMIAUTOMATIC Open Pause Close Pause CONDOMINIUM Open with auto...

Страница 11: ...F 8 6 9 6 10 6 N O 8 9 6 6 PHOTOCELLS OPENS STOP LED FLASHING LIGHT 28 Vdc Max 2W CLOSES STEP BY STEP OPENED GATE LIGHT PEDESTRIAN 28 Vdc Max 2W 3 3 Electrical connec on N O COM FLASHING GATE LIGHT COURTESY LIGHT ANTENNA COMMON COMMANDS STOP CLOSES PEDESTRIAN STEP BY STEP OPENING SAFETY OPENS EXIT CLOSING PHOTO Control unit output 1 2 3 4 5 6 7 8 Encoder Encoder A Encoder B Encoder Motor Motor Tra...

Страница 12: ...ault operating parameters At the end of the cycle the icon comes on to confirm that the automation is ready to work Once the setup is completed the B button becomes a STEP BY STEP command if pressed Turn off the power press and hold the buttons A and B at the same time power on and hold buttons pressed until a H flashes on the display now release the buttons all the parameters are reset to factory de...

Страница 13: ...ss and release the B bu on the P icon comes on the display now press the key of the remote transmi er that you want to program within 5 the correct storage is highlighted with a short flash on the display in order to program addi onal transmi ers press in sequence the keys on the transmi ers if no signal is transmi ed a er a few seconds the icon comes on to confirm that the automa on is ready to w...

Страница 14: ...rrect storage is confirmed with steady light for a few seconds you can program only one radio control at once 2 Press again the same radio control bu on for 3 in a row you enter the par al opening setup the memory is ready for storage the flashing light performs two short flashes Now press the key on the new remote transmi er that you want to program the correct storage is confirmed with steady li...

Страница 15: ...isplay indicates with the icon the adjusted level that goes from 0 to 5 with bu ons A and B you can adjust the level according to the table shown below a er 5 the system automa cally quits and stores the last level Press Press Press Press 0 Opera ng Op ons 0 Semi automa c Default 1 Condominium 2 Open Stop Close Stop 3 Opens Closes 4 Man s switch 5 1 Automa c Closing 0 No Default 1 5 2 10 3 30 4 60...

Страница 16: ...4 Slowdown Space Adjustment 0 Minimum 1 2 Default 3 4 5 Maximum 5 Slowdown Speed level 0 Minimum 1 2 Default 3 4 5 Maximum 6 Pedestrian opening 0 10 Of complete cycle 1 20 2 30 Default 3 40 4 50 5 60 7 Reversal Point Adjustment 0 Minimum 1 2 Default 3 4 5 Maximum Minimum Maximum Minimum Maximum ...

Страница 17: ...he input is disabled Press A to advance the sequence when the segment is on the contact is ac ve Press Press Press Input 7 STOP Input 11 SAFETY IN OPENING Input 12 PHOTO ATTENTION PLEASE NOTE A er enabling the safety inputs check their correct func oning 7 VISUALIZATION OF THE INPUT STATUS VIA DISPLAY Press and release the A bu on for 30 it is possible to view the status of the inputs according to...

Страница 18: ...ery Fuse 5x20 8 CONNECTION WITH EMERGENCY BATTERIES OPTIONAL AGEX KIT The backup ba eries allow you to have an emergency solu on in cases of power failure the autonomy is around 8 hours and or approximately ten maneuvers For the connec ons follow the diagram shown here Transformer output Card Input Batteries Switching Transformer Electronic control unit Red Black ...

Страница 19: ...fect working order and in compliance with the intend use in the awareness of safety and hazard condi ons and in compliance with the instruc ons for installa on and use Any dysfunc ons that may pose threats to safety must be eliminated immediately The electromechanical operator may not be used in environments prone to flooding Do not use the operator in environmental condi ons characterised by hars...

Страница 20: ...rnesses protec ve helmet and all other equipment required by law and the standards governing this kind of work 12 TESTING AND TRIAL RUN The tes ng and trial run must be performed by a COMPETENT PERSON supervised and aided by a PROFESSIONAL FinER It is the responsibility of the person who tests and sets up the automa on of which the control unit is a part to perform the checks required in accordanc...

Страница 21: ... non observance of the informa on on use contained in this manual and the failure to observe the safety indica ons given below The Manufacturer declines responsibility for damage and malfunc ons caused by non compliance with the instruc ons for use Keep this manual in a safe and easily accessible place so that it can be consulted rapidly when necessary Before ac va ng the gate ensure that all pers...

Страница 22: ...a PROFESSIONAL FinER only If a fault that cannot be solved following the information contained in the present manual arises contact the manufacturer s assistance service All maintenance repair or replacement of parts must be recorded in the maintenance log which is SUPPLIED AND INITIALLY FILLED IN BY THE FinER 14 2 Routine maintenance Every 6 months a PROFESSIONAL FinER should repeat the series of...

Страница 23: ...ASSA TENSIONE LVD 2014 35 UE DIRETTIVA COMPATIBILTA ELETTROMAGNETICA EMC 2014 30 UE DIRETTIVA RADIO E TERMINALI DI TELECOMUNICAZIONE RED 2014 53 UE Name of signatory Rui Michele Position CEO Signature COLLE UMBERTO 18 05 2022 CONFORMITYDECLARATION EU OF THE MANUFACTURER Declares that the following product Electromechanical operator is for sectional doors Serial number Production lot It complies wi...

Страница 24: ...www homelife it Adress Via Sandro Pertini 3 5 31014 Colle Umberto TV ITALY Telephone 39 0438 388592 Telefax 39 0438 388593 http www homelife it e mail info homelife it ...

Отзывы: