14
Table 6: Technical specifications
MULTI POSITIONS MODELS - SERIES 098
RATING AND PERFORMANCE
Firing rate (USGPH)*
0.50
0.60
0.70
0.50
0.60
0.70
Input (BTU/h)*
70 000
84 000
98 000
70 000
84 000
98 000
Maximum Heating capacity, (BTU/h)*
59 000
70 000
81 000
59 000
70 000
81 000
Heating temperature rise (Degr. F)*
Flue draft with chimney (inch of w.c.)
Overfire pressure with chimney (inch of w.c.)
Flue pressure with direct vent (inch of w.c.)
Overfire pressure with direct vent (inch of w.c.)
BECKETT BURNER; MODEL NX (Chimney or DV)
Burner tube insertion length (inches)
Head type
Nozzle (Delavan)
0.40 - 60A
0.50 60A
0.60 - 60A
0.40 - 60A
0.50 - 60A
0.60 - 60A
Pump pressure (PSIG)*
155
145
135
155
145
135
Head/Air setting
0.5
1.5
2.5
0.5
1.5
2.5
AFUE % (From CSA B212 standard and Canadian regulation)**
85.0 ‡
84.2
81.9
85.0 ‡
84.2
81.9
AFUE % (From ASHRAE 103 standard and US regulation)**
85.0 ‡
83.9
81.9
85.0 ‡
83.9
81.9
RIELLO BURNER; MODEL 40-F3 (Chimney)
Burner tube insertion length (inches)
Nozzle (Delavan)
0.40 - 70A
0.50 - 70A
0.60 - 70A
0.40 - 70A
0.50 - 70A
0.60 - 70A
Pump pressure (PSIG)*
155
145
135
155
145
135
Combustion air adjustment (turbulator/damper)
0 / 1.5
0 / 2.5
1 / 3.5
0 / 1.5
0 / 2.5
1 / 3.5
AFUE % (From CSA B212 standard and Canadian regulation)**
85.0 ‡
84.2
81.9
85.0 ‡
84.2
81.9
AFUE % (From ASHRAE 103 standard and US regulation)**
85.0 ‡
83.9
81.9
85.0 ‡
83.9
81.9
RIELLO BURNER; MODEL 40-BF3 (Direct vent DV)
Burner tube insertion length (inches)
Nozzle (Delavan)
0.40 - 70A
0.50 - 70A
0.60 - 70A
0.40 - 70A
0.50 - 70A
0.60 - 70A
Pump pressure (PSIG)*
155
145
135
155
145
135
Combustion air adjustment (turbulator/damper)
0 / 3.25
0 / 4
1 / 5.25
0 / 3.25
0 / 4
1 / 5.25
AFUE % (From CSA B212 standard and Canadian regulation)**
85.0 ‡
84.2
81.9
85.0 ‡
84.2
81.9
AFUE % (From ASHRAE 103 standard and US regulation)**
85.0 ‡
83.9
81.9
85.0 ‡
83.9
81.9
ELECTRICAL SYSTEM
Volts - Hertz - Phase
Rated current (Amps)
Minimum ampacity for wire sizing (Amps)
Max. fuse size (Amps)
Control transformer (VA)
External control power available Heating (VA)
Cooling (VA)
BLOWER DATA
Heating blower speed at 0.25" W.C. SP
MED-LOW
MED-HIGH
HIGH
Heating blower speed at 0.50" W.C. SP
MED-LOW
MED-HIGH
HIGH
Motor (HP) / number of speeds
Blower size (diam. x width)
GENERAL INFORMATION
Overall dimensions (width x depth x height)
Supply air opening (width x depth)
Return air opening (width x depth)
Filter size (depth x hieght x thickness)
Shipping weight Lbs/Kg
Air conditioning, maximum output (tons) at 0.5 SP
10'' x 8''
10'' x 8''
2.5
3.0
20'' x 20''
20'' x 20''
125 / 57
125 / 57
16'' x 19''
16'' x 19''
30
30
See the ECM air flow table
1/3 HP / 4 speeds
1/2 HP / ECM
40
40
40
40
115 - 60 - 1
115 - 60 - 1
15
15
10.3
13.7
12.2
12.2
BF3
BF3
2 3/4''
2 3/4''
F3 WITH AIR INLET DAMPER
F3 WITH AIR INLET DAMPER
2 3/4''
2 3/4''
1 3/4''
1 3/4''
6 - Slot LQ head
6 - Slot LQ head
-0.035 to +0.010
+0.03 to +0.15
NX56LQ
NX56LQ
UNITS WITH 1/3 HP PSC MOTOR
UNITS WITH 1/2 HP ECM MOTOR
55 - 85 Degr. F
55 - 85 Degr. F
-0.06 to -0.025
-0.06 to -0.025
-0.035 to +0.010
19'' x 19''
19'' x 19''
+0.05 to +0.20
+0.05 to +0.20
+0.03 to +0.15
16.875'' x 20 1/8'' x 40 3/4''
16.875'' x 20 1/8'' x 40 3/4''
* INPUT & OUTPUT ADJUSTMENT
Pump pressure can be adjusted to maintain proper firing rate.
‡ =
Increase pump pressure if flue gases temperature is under 400˚F
Adjust the total flue gas temperature between 400˚F and 575˚F (330˚F and 505˚F net approximately)
** AFUE value established after minimum 20 hours of operation.
Содержание OMF098J10B
Страница 17: ...17 Figure 9 Furnace dimensions ...
Страница 18: ...18 Figure 10 Wiring diagram 4 speed motor PSC ...
Страница 19: ...19 Figure 11 Wiring diagram variable speed motor ECM ...
Страница 20: ...20 Figure 12 Parts list with 4 speed motor PSC B50064G ...
Страница 22: ...22 Figure 13 Parts list with variable speed motor ECM B50074G ...