INSTALLATION
The Starter Lockout output circuit drives a normally closed relay, which interrupts the starting
signal when the output has been activated. See Figure 5-29.
Figure 5-29
Starter Lockout
5.23.3
PROGRAMMING REQUIREMENTS AND FLEXIBILITY
Starter Lockout may be enabled or disabled as listed in Table 5-71 with VEPS or DRS.
Parameter
Group
Parameter
Setting
Options
Default
35
3 17 DO Selection
1 – Enable Starter Lockout
0 – Disabled
1 – Enable Starter Lockout
2 – Enable kick down output*
3 – Not used
4 – Optimized Idle Alarm
5 – Split Valve*
6 – Starter L AGS2
7 – Engine brke disabled for
over speed*
0 –
Disabled
35
3 17 DO Fault
Detection
0 = Enable
1 = Disable
0 –
Disabled
* Not supported in NAFTA