DDEC VI ELECTRONIC CONTROLS APPLICATION AND INSTALLATION
4.3.13
LOW OIL PRESSURE LAMP
This digital output is switched to ground when a low oil pressure fault is detected.
NOTE:
This function is optional.
Installation
This digital output circuit is designed to sink no more than 250 mA (DC) current.
The Low Oil Pressure Lamp is wired to pin 3/12 of the CPC.
Programming Requirements and Flexibility
The options for this digital output are listed in Table 4-39.
Parameter
Group
Parameter
Setting
Options
Default
Access
35
3 12 DO
Selection
3 – Oil Pressure
Low Lamp
0 – Disabled
1 – Oil Level Lamp*
2 – AGS2 Check Transmission
Indication Lamp
3 – Oil Pressure Low Lamp
4 – Cruise Active Lamp
5 – FUSO Retarder Control 2*
0 – Disabled
VEPS or
DRS
35
3 12
DO Fault
Detection
—
0 — Disabled
1 — Enabled
0 – Disabled
VEPS or
DRS
* Not supported in NAFTA
Table 4-39
Low Oil Pressure Lamp Programming Options
4.3.14
MALFUNCTION INDICATOR LAMP (MIL)
This amber warning lamp is illuminated for all active engine emission related faults including
but not limited to after-treatment devices. The MIL may illuminate at the same time as the
Amber Warning Lamp.
This is a required lamp. It can be hardwired or multiplexed.
NOTE:
This digital output is REQUIRED.
Installation
This digital output circuit is designed to sink no more than 250 mA (DC) current.
The Malfunction Indicator Lamp is wired to pin 1/13 of the CPC.
All information subject to change without notice.
(Rev. 01/07)
4-41