DDEC VI ELECTRONIC CONTROLS APPLICATION AND INSTALLATION
4.3.11
LOW BATTERY VOLTAGE LAMP
This digital output is switched to ground when a low battery voltage fault is detected.
NOTE:
This function is optional.
Installation
This digital output circuit is designed to sink no more than 2.0 A (DC) current.
The Low Battery Voltage Lamp is wired to pin 3/10 of the CPC.
Programming Requirements and Flexibility
The options for this digital output are listed in Table 4-37.
Parameter
Group
Parameter
Setting
Options
Default
Access
35
3 10 DO
Selection
3 – Battery Voltage
Low Lamp
0 – Disabled
1 – Air Filter Lamp*
2 – AGS2 Transmission Temp
Indication Lamp
3 – Battery Voltage Low Lamp
4 – Coolant Level Low Lamp
5 – FUSO Retarder Control 1*
0 – Disabled
VEPS or
DRS
35
3 10
DO Fault
Detection
—
0 — Disabled
1 — Enabled
0 – Disabled
VEPS or
DRS
* Not supported in NAFTA
Table 4-37
Low Battery Voltage Lamp Programming Options