DDEC VI ELECTRONIC CONTROLS APPLICATION AND INSTALLATION
The probe should be located in either the radiator top tank or a remote mounted surge tank. It
should be mounted horizontally in the center of the tank and must be in a position to signal low
coolant before aeration occurs. Typically, this is a height representing 98% of the drawdown
quantity. The probe should be located so that it is not splashed by deaeration line, stand pipe or
coolant return line
fl
ows. The insulated portion of the probe should be inserted into the coolant
1/2 in. or more past the inside wall of the tank. See Figure 3-30.
Figure 3-30
Engine Coolant Level Sensor Location - Top of Radiator Tank
Determine proper location for low coolant level sensor while running the drawdown test. It
must
actuate a warning before the satisfactory drawdown level is reached.
The ECL Sensor components are OEM supplied hardware and can be purchased as kits or
individual components, depending on OEM requirements.
All information subject to change without notice.
(Rev. 01/07)
3-99