    Page 8                                               Copyright © 1995-97 Detection Systems, Inc.                   DS1520/30 Installation Instructions

Fault

Condition

false alarm

no alarm

Power supply

O.K.

Wiring fault

no

Wiring fault

no

C onnect meter

to test point.

Wait 2 minutes.

Scratch on

detector with

a screwdriver.

yes

yes

What is

the voltage?

Alarm

within 30 seconds?

no

Detector

malfunction

1520: E<0.3V

E>3V

1530: E>5V

E>1V

E<3V

E>0.3V

E<1V

Intermittent

disturbances

Scratch on

protected surface

with a

screwdriver

Disturbance

of detector

from outside

Cover

detector with

a sound

absorbing

material

no

Poor

mechanical

coupling with

surface,

tighten mounting

screws

Alarm

within 30

seconds?

yes

Check for

ultrasound

detectors

in the area.

Cause is

vibrations in

the protected

surface. Read

planning instructions.

voltage

nominal?

yes

no

(Re)adjust sensitivity

yes

Installation

OK

false

alarm?

yes

no

Power supply

O.K.

Detector

malfunction

Power supply range:

9-15 vdc

Less than 2 vac ripple

Normal voltage:

DS1520 0.7 vdc or less

DS1530 0.0 vdc

9.0  Troubleshooting Chart

Содержание DS1520

Страница 1: ...eate mechanical vibra tions in the protected structure This includes but is not limited to Electric Motors Transformers Fans Air Conditioners Water Pipes Ultrasound Detectors Bells Human Activity may...

Страница 2: ...ultiple Detectors If mounting inside the body mount a detector on a space which is clear and easily accessible e g the ceiling Also mount a detector on the inside of a door close to the hinges It is a...

Страница 3: ...ce away from the mounting surface A A A B C A Holes for mounting the detector B Hole for mounting the plate to the concrete expansion plug C Hole for marking the mounting hole for the VS A14 if used A...

Страница 4: ...the Junction Box and Day plate together on the side of the safe vault or a nearby wall so that cable will prevent the safe vault door from opening when the detector is moved to the Night plate Mount...

Страница 5: ...mbly inside the box 6 1 5 Surface Mounting with the VS A3 The VS A3 is a box designed to protect the detector from damage and excess humidity A A A B C Place rubber gasket between the box and the cove...

Страница 6: ...switch closed 6 0 2 Wiring the VS A6 Movable Mounting Kit The movable mounting kit has a two terminal T strip It includes a microswitch and a reed switch They both are supervising whether the detecto...

Страница 7: ...Transmitter The Test Transmitter is mounted inside the detector It is activated by sup plying it with 12 volts Upon activation it will transmit signals that will alarm the detector Mount the test tran...

Страница 8: ...nces Scratch on protected surface with a screwdriver Disturbance of detector from outside Cover detector with a sound absorbing material no Poor mechanical coupling with surface tighten mounting screw...

Отзывы: