1. Introduction

1.1 Description

Detcon  Model  DM-700  toxic  gas  and  O

2

deficiency  sensors  are  non-intrusive 

“Smart” sensors designed to detect and monitor a wide range of toxic gasses in air.  
Ranges of detection for toxic gasses are from 0-1ppm up to 0-10,000ppm.  Ranges 
for O

2

deficiency are 0-100ppm up to 0-25% by volume.  The sensor features an LED 

display of current reading, fault and calibration status.  The Sensor is equipped with 
standard analog 4-20mA and Modbus™ RS-485 outputs.  A primary feature of the 
sensor is its method of automatic calibration, which guides the user through each step 
via fully scripted instructions displayed on the LED display.

The microprocessor-supervised electronics are packaged in an encapsulated module 
and  housed  in  an  explosion  proof  casting,  called  the  ITM  (Intelligent  Transmitter 
Module).    The  ITM  includes  a  four  character  alpha/numeric  LED  used  to  display 
sensor  readings,  and  the  sensor’s  menu  driven  features  when  the  hand-held 
programming magnet is used.

Electrochemical Sensor Technology

The Toxic gas sensors are based on electrochemical cells.  Each cell consists of three electrodes embedded in an 
electrolyte solution all housed beneath a diffusion membrane.  Sensitivity to specific target gasses is achieved 
by varying composition of any combination of the sensor components.  Good specificity is achieved in each 
sensor type.  The cells are diffusion limited via small capillary barriers resulting in a long service life of up to 
three or more years.  The electrochemical cell is packaged as a field replaceable intelligent plug-in sensor.  

Figure 1 Construction of Electrochemical Toxic Sensor

The O

2

deficiency sensor technology is a two electrode galvanic metal air battery type cell, which is housed as 

a  field replaceable  intelligent  plug–in  sensor.    The  cell  is  diffusion  limited  and  functions  as  a  direct  current 
generator proportional to the amount of oxygen adsorption.  The sensors are temperature compensated and show 
good accuracy and stability over the operating temperature range of –20° to 50°C (-4° to +122° Fahrenheit).  
The sensor is warranted for two years and has an expected service life of up to 2.5 years in ambient air at 20.9% 
oxygen. 

Содержание DM-700

Страница 1: ...ciency Sensors This manual covers all ranges of electrochemical and O2 deficiency sensors offered in the Detcon Product Line DETCON Inc 4055 Technology Forest Blvd The Woodlands Texas 77381 Ph 281 367...

Страница 2: ...intentionally blank Shipping Address 4055 Technology Forest Blvd The Woodlands Texas 77381 Mailing Address P O Box 8067 The Woodlands Texas 77387 8067 Phone 888 367 4286 281 367 4100 Fax 281 292 2860...

Страница 3: ...21 3 5 1 View Sensor Status 21 3 5 2 Set AutoSpan Level 22 3 5 3 Set Serial ID 23 3 5 4 Set Range 23 3 5 5 Signal Output Check 24 3 5 6 Restore Factory Defaults 24 3 6 Program Features 25 3 6 1 Opera...

Страница 4: ...ox 8 Figure 10 Outline and Mounting Dimensions Aluminum Junction Box 9 Figure 11 Outline and Mounting Dimensions Mini Stainless Steel Junction Box 9 Figure 12 Typical Installation 11 Figure 13 Sensor...

Страница 5: ...M 700 ii Shipping Address 4055 Technology Forest Blvd The Woodlands Texas 77381 Mailing Address P O Box 8067 The Woodlands Texas 77387 8067 Phone 888 367 4286 281 367 4100 Fax 281 292 2860 www detcon...

Страница 6: ......

Страница 7: ...ld programming magnet is used Electrochemical Sensor Technology The Toxic gas sensors are based on electrochemical cells Each cell consists of three electrodes embedded in an electrolyte solution all...

Страница 8: ...fast response times and improved calibration repeatability on highly corrosive gas types The ITM circuit functions include extensive I O circuit protection on board power supplies internal intrinsica...

Страница 9: ...Intelligent Plug in Sensor varies by gas type and range 3 Model DM 700 Splash Guard Adapter 4 Splash Guard NOTE All metal components are constructed from electro polished 316 Stainless Steel in order...

Страница 10: ...blems The intelligent design provides automatic recognition of gas type units full scale range and calibrations data when a new sensor is plugged in The sensor can be accessed and replaced in the fiel...

Страница 11: ...greater than 40 000 PSI typical 80 000 PSI should then be tightened down to keep the Housing Bottom from being inadvertently removed or from becoming loose under vibration The locking setscrew ensure...

Страница 12: ...leak sources within an industrial process include flanges valves and tubing connections of the sealed type where seals may either fail or wear Other leak sources are best determined by facility engin...

Страница 13: ...rence Table refer to Section 9 lists the gasses typically found in industrial environments that may cause a cross interference response on members of the Detcon family of toxic gas sensors Review Tabl...

Страница 14: ...mbly only 4 3 4 NPT Explosion Proof Enclosure Junction Box Sensor Assembly Splash Guard Detcon s SS Junction Box shown 2 125 5 5 12 7 Typ Mounting Bolt Use Spacers to move the J Box and Sensor Assembl...

Страница 15: ...from the wall at least 0 25 0 5 to allow access to Sensor Wall or other mounting surface 0 265 x2 Spacer Mounting Holes 8 32 Thread Ground Point Figure 10 Outline and Mounting Dimensions Aluminum Junc...

Отзывы: