PIR Detector 

9721WHW 

 

 

 

 

 

 

 

 

 

 

DETA Electrical Company Limited 

Kingsway House  Laporte Way 

Luton  Bedfordshire  LU4 8RJ  UK 

NPD 0519 

April  2016            MCINS10 V1                                                                                                                                                                                                              

Tel: +44 (0)1582 544 544   Technical Helpline: +44(0)1582 544 548

 

Connect 

            

 

 

Sending ‘on’ or ‘on & off’ commands 

Once the PIR is linked, moving the ‘Learn’ slider to the position marked ‘1’ 
will turn on any linked devices when the PIR is triggered. Moving the slider 
to the ‘1/0’ position will turn on linked devices, but also send an ‘off’ 
command after a customisable delay period (see next section). 

 

 
Setting the ‘off’ command delay 

 

If the Learn slider is set to ‘1/0’, then an ‘off’ command will be sent to a 
linked Deta Connect device after the initial ‘on’ command sent by the PIR. 
The period of time between these two commands can be customised 
using the ‘Time delay’ slider. It has 4 positions: 5 sec/1 min/5 min/10 min. 
The delay countdown will begin once movement is no longer detected after 
the initial ‘on’ command has been sent. 

 
Setting the light sensitivity 

Setting the light sensitivity on the PIR sensor determines the light level at 
which the PIR sensor will become active. The sensitivity can be set by 
moving the position of the Lux slider marked ‘H/M/L’. 

 

The slider has 3 positions: ‘H/M/L’. 
• In position ‘H’ the PIR will be active at all light levels. 
• In position ‘M’ the PIR will only become active at low daylight levels. 
• In position ‘L’ the PIR will only become active in darkness (or very low 
light). 
NOTE: When adjusting the Lux setting it may take up to 30 seconds for the 
PIR to acclimatise to the new light setting. 

 
 
 
Finalising Setup 

Once the PIR has been linked to its target Deta Connect 
 devices and the 
settings adjusted, it can be mounted in its final position. Once in position, it 
is important to allow at least 30 seconds for the PIR to acclimatise to the 
light level in its new environment. Until this process has taken place, the unit 
may not perform as expected. 

 
Battery Low Indicator 

The ‘Battery low’ indicator is positioned inside the sensor lens. If the battery 
is low, the indicator will blink after the PIR has sent a command to inform 
that the batteries need changing.

 

 

 

Important things to consider 

 
Signal Range 
 

 

Reliable range of operation is approximately 15 metres indoors and up 
to 100m outdoors using the Connect Link/WiFi-Link. This figure may 
vary depending upon the environment; very thick walls, bodies of 
water or large metal objects may interfere with radio range. 

 

If the distance between the transmitter and receiver is too great to 
achieve reliable operation, the Connect Signal Booster may be used in 
conjunction with this product to increase the range. 
 

 

Voltage 

2 x 1.5V 

Battery Type 

AAA 

 

 

Radio Frequency 

433.92MHz 

 

Lux slider 

Learn slider 

Delay slider 