background image

Legend: 

 
        Rinsing solenoid valve   
        control cable         
        Sea water 
        Fresh water 
        HP hose pump 
        membranes 
 
 
 
 
 

Fresh water tank 

Diam. 12 N°8 

N

°2

 

Production  

Diam. 10 N°3 

Diam.12 N°4 

Diam.12 

  D E S S A L A T O R ,   Z . I .   d e s   3   M o u l i n s - 2 8 2 ,   r u e   d e s   C i s t e s -

  B â t .  

«   E u r o   9 2   »   D ,   0 6 6 0 0   A n t i b e s   .  

T é l :  

( 3 3 )   ( 0 ) 4   9 3   9 5   0 4   5 5  

F a x :  

( 3 3 )   ( 0 ) 4   9 3   9 5   0 4   6 6  

e - m a i l :  

c o n t a c t @ d e s s a l a t o r . c o m  

 

Filter 

Width: 310 
Height: 390 
Depth: 240 

Membranes 

Length: 700 
Width: 270 
Height: 120 

N°1 HP 

Control panel 

Length: 320 
Width: 200 
Depth: 150 

Motor 12 V or 24 V 

I n s t a l l a t i o n   d i a g r a m   D e s s a l a t o r   D U O   1 0 0   A C & D C  

B i   p o w e r e d :   1 2   o r   2 4   V   A N D   1 2 0 V   o r   2 3 0   V  

Motor 120 V or 230 V 

Motor unit 

Length: 710 
Width: 400 
Height: 240 

Negative connection on motor with  
Green/yellow cable:  35 mm² en 12V et 24 V 

Positive connection on  relay  
with brown cable: 35 mm² 

Co

n

tr

o

l c

ab

le 

3x1

.5

m

m

² 

Ca

b

le 

 3

x1

.5

m

m

² 

Power supply 120 V or 230 V 
 (circuit breaker) 

W

ater 

line

 

Waste oulet 

Rinsing with  
pressurized fresh water 
(Board pump) 

Strainers need to 
be looking forward 
on the hull of boat  

Содержание DUO100

Страница 1: ...d wide producing 100 L Hr with automatic rinsing model patented DESSALATOR Technical and Sales Departments Z I des 3 Moulins Euro 92 B t D rue des Cistes 06600 ANTIBES FRANCE Tel 33 0 4 93 95 04 55 Fa...

Страница 2: ...g the membranes page 8 5 2 Rinsing the membranes page 9 5 3 Sterilizing the membranes page 10 5 4 High pressure pump page 10 6 Spare parts and accessories page 11 Appendix A1 Reverse osmosis page 12 A...

Страница 3: ...es Length 700 Width 270 Height 120 N 1 HP Control panel Length 320 Width 200 Depth 150 Motor 12 V or 24 V I n s t a l l a t i o n d i a g r a m D e s s a l a t o r D U O 1 0 0 A C D C B i p o w e r e...

Страница 4: ......

Страница 5: ...ventilated space BEWARE In 120V please think of an even more important ventilation of the motor unit than in 230V Membrane unit The membrane unit includes 3 membranes 2521 assembled in a compact fram...

Страница 6: ...the output of your board pump An electro valve is mounted on the output diam 12 for automatic rinsing It can be connected under a sink a wash basin or on the way of pressurized cold water hoses The va...

Страница 7: ...the male and female cones before joining 2 3 Electrical connections Negative battery cable 4 Positive battery cable 3 Please connect a fuse holder to this cable Neutral blue phase brown Ground Yellow...

Страница 8: ...ors should be installed strictly in accordance with the instructions Appendix A2 Apply a little loctite or nut seal to the two male and female cones before tightening Recommendation To facilitate the...

Страница 9: ...alve on the fresh water tank outlet A Tricoflex waste oulet inner 12mm hose4 will also be required which can be connected to a sink wash basin or cockpit water drain to avoid having the hull redrilled...

Страница 10: ...h on 5 Turn the pressure regulator dial to the right until the HP gauge reading is in the orange zone then gradually adjust until the needle reaches the beginning of the green zone Check that the pres...

Страница 11: ...e exposed to temperatures above 60 C as high temperatures may also prevent salt from being removed Drying out of the membranes The membranes should be permanently immersed in liquid either sea water b...

Страница 12: ...r produced falls it does not necessarily mean that the membrane needs to be replaced 5 2 Rinsing the membranes Once a week the watermaker needs to be flushed with fresh water before using it to make f...

Страница 13: ...panel will turn on which indicates that flushing is in process This should take 30 seconds and will stop automatically The green and orange lights will shut off and the only indicator will be the blue...

Страница 14: ...g a garden spray Pour the entire packet contents of sterilizer into a bucket containing 8 litres of fresh water and mix thoroughly Fill the spray bottle with this mixture and spray the sterilizer into...

Страница 15: ...lways possible running without enough water accidental overpressure impact Should the need arise we supply spare parts and maintenance accessories 5 m 10 ft filter driving belt motor relays production...

Страница 16: ...onsumable Pay attention not to allow chlorine into the desalination system as this could damage the device How does your desalinator work Sea water enters the inlet valve which penetrates the hull Thi...

Страница 17: ...p where the steel threading disappears into the brass end piece a gap of approximately 7mm between the nut and the brass union 4 Unscrew the nut of the tapered adaptor The connector is now ready for t...

Страница 18: ...re filter Remove the 5 m cartridge from the pre filter 10 Replace with the sterilizing cartridge ST2 Replace the 5 m cartridge with the sterilizing cartridge ST2 11 Set the rinsing valve to pressurize...

Страница 19: ...it manually MANUAL RINSING Your Dessalator is equipped with an automated rinsing Here below the procedure to rinse manually HP pump Fresh water inlet Sea water inlet HP pump Fresh water inlet Sea wate...

Страница 20: ...and filters clean Replace seals Oil leak on HP pump Worn seals on connecting rods Replace the seals Insufficient water flow Very cold water Dirty pre filter Tension drop on the power cable Replace the...